Skip to main content
ENERGY STAR water heater model · PD 3942806

Eco-Logical ECO-65HPM1A Water Heater Specifications (3.9 UEF)

Certified at 3.9 UEF across its 60-gallon nominal tank, 80 gal First Hour Rating, Eco-Logical ECO-65HPM1A (Hybrid/Electric Heat Pump, Electric) places #144 of 706 out of 706 ENERGY STAR models (PD 3942806). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.40 / +56.0%. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bosch TR7000T-65CA (3.9 UEF).

Uniform Energy Factor
3.9 UEF
Cohort UEF Rank
#144 of 706 (top 22.9%)
First Hour Rating
80 gal
Storage Volume
60 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.40 / +56.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Eco-Logical ECO-65HPM1A at 3.9 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Eco-Logical ECO-65HPM1A: 3.90
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Eco-Logical ECO-65HPM1A relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.9 UEF, Eco-Logical ECO-65HPM1A places #144 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.20 UEF vs. 3.70 UEF median).

Eco-Logical ECO-65HPM1A clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.40 UEF (+56.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Eco-Logical ECO-65HPM1A runs ~$225/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Eco-Logical ECO-65HPM1A: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Eco-Logical ECO-65HPM1A include Bosch TR7000T-65CA (3.9 UEF, at parity) alongside Custom Comfort CCOHPWH65A (3.9 UEF, at parity).

Where Does Eco-Logical ECO-65HPM1A Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Eco-Logical ECO-65HPM1A holds #144 of 706 (top 22.9%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandEco-Logical6 certified listingsENERGY STAR PD 3942806
Model NumberECO-65HPM1ADraw pattern: High-UsageECO-65HPM1A
Uniform Energy Factor (UEF)3.9+0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)80 gal+8 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2025-01-16Certified 2025-01-16Markets: United States, Canada

How Much Electricity Does ECO-65HPM1A Use in Different States?

Estimated at $225/yr nationally (1,240 kWh/yr), 10-year utility spending for Eco-Logical ECO-65HPM1A shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,295
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $18,952
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $11,951
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,391
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $5,877
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Eco-Logical Units?

No open CPSC recall alerts appeared for Eco-Logical as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ECO-65HPM1A?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Eco-Logical ECO-65HPM1A's gallon capacity and 3.9 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bosch TR7000T-65CA Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Custom Comfort CCOHPWH65A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Kepler AZMCHW-65VN3A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Midea CAN3-RSJ-15/250RDVN3-L3 Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Bosch TR7000T-65US Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240

When Should Homeowners Skip Eco-Logical ECO-65HPM1A (Hybrid/Electric Heat Pump)?

Check Eco-Logical ECO-65HPM1A's mechanical constraints—including utility space, Electric capacity, and Pass: +1.40 / +56.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Eco-Logical ECO-65HPM1A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Eco-Logical ECO-65HPM1A directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Eco-Logical ECO-65HPM1A Strong Fit — 3.9 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Bosch TR7000T-65CA footprint.

Common Homeowner Questions for Eco-Logical ECO-65HPM1A

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Eco-Logical ECO-65HPM1A stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.9 UEF, Eco-Logical ECO-65HPM1A shows Pass: +1.40 / +56.0% relative to May 6, 2029 federal DOE limits while placing #144 of 706 (top 22.9%) among 706 Hybrid/Electric Heat Pump peers like Bosch TR7000T-65CA.

Will Eco-Logical ECO-65HPM1A fit through a standard utility door and 72-inch basement ceiling?

Measuring 45.5 in. tall by 21.8 in. diameter, Eco-Logical ECO-65HPM1A notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Eco-Logical ECO-65HPM1A during replacement?

Electrical specs for Eco-Logical ECO-65HPM1A call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Eco-Logical ECO-65HPM1A?

At 18.16 cents/kWh national residential pricing, Eco-Logical ECO-65HPM1A's 1,240 kWh/yr draw equals roughly $225 annually or $2,250 across a 10-year horizon (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).

When is Eco-Logical ECO-65HPM1A a poor fit for a residential replacement?

Avoid placing Eco-Logical ECO-65HPM1A directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Eco-Logical ECO-65HPM1A deliver?

With 80 gal FHR (+8 gal vs. 72 gal median), Eco-Logical ECO-65HPM1A fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Eco-Logical ECO-65HPM1A?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Eco-Logical; verify exact manufacturing week for Eco-Logical ECO-65HPM1A using the Serial Number Lookup tool.

Does Eco-Logical ECO-65HPM1A qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Eco-Logical ECO-65HPM1A. Closest peer in Hybrid/Electric Heat Pump is Bosch TR7000T-65CA (3.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks