Skip to main content
ENERGY STAR water heater model · PD 3722796

Bosch TR7000T-65US Water Heater Specifications (3.9 UEF)

Certified at 3.9 UEF across its 60-gallon nominal tank, 80 gal First Hour Rating, Bosch TR7000T-65US (Hybrid/Electric Heat Pump, Electric) places #144 of 706 out of 706 ENERGY STAR models (PD 3722796). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.40 / +56.0%. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Custom Comfort CCOHPWH65A (3.9 UEF).

Uniform Energy Factor
3.9 UEF
Cohort UEF Rank
#144 of 706 (top 22.9%)
First Hour Rating
80 gal
Storage Volume
60 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.40 / +56.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Bosch TR7000T-65US at 3.9 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Bosch TR7000T-65US: 3.90
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Bosch TR7000T-65US relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.9 UEF, Bosch TR7000T-65US places #144 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.20 UEF vs. 3.70 UEF median).

Bosch TR7000T-65US clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.40 UEF (+56.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Bosch TR7000T-65US runs ~$225/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Bosch TR7000T-65US: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Bosch TR7000T-65US include Custom Comfort CCOHPWH65A (3.9 UEF, at parity) alongside Eco-Logical ECO-65HPM1A (3.9 UEF, at parity).

Which Specs Set Bosch TR7000T-65US Apart From Cohort Averages?

Ranked #144 of 706 (top 22.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, Bosch TR7000T-65US is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandBosch12 certified listingsENERGY STAR PD 3722796
Model NumberTR7000T-65USDraw pattern: High-UsageTR7000T-65US
Uniform Energy Factor (UEF)3.9+0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)80 gal+8 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2025-01-16Certified 2025-01-16Markets: United States

How Do Regional kWh Prices Impact TR7000T-65US Over 10 Years?

Using EIA Table 5.6.A benchmarks, Bosch TR7000T-65US's 1,240 kWh/yr draw translates to roughly $225/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,295
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $18,952
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $11,951
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,391
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $5,877
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Bosch Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Bosch; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Custom Comfort CCOHPWH65A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Eco-Logical ECO-65HPM1A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Kepler AZMCHW-65VN3A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Midea CAN3-RSJ-15/250RDVN3-L3 Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Midea MAHW-65VN3A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240

Who Is Bosch TR7000T-65US Best For — and When Should You Pick Custom Comfort CCOHPWH65A?

Evaluate whether Bosch TR7000T-65US's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Bosch TR7000T-65US needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Bosch TR7000T-65US directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Bosch TR7000T-65US Strong Fit — 3.9 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Custom Comfort CCOHPWH65A footprint.

Frequently Asked Technical Questions: Bosch TR7000T-65US

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Bosch TR7000T-65US (3.9 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Bosch TR7000T-65US records 3.9 UEF (Pass: +1.40 / +56.0%), placing #144 of 706 (top 22.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Bosch TR7000T-65US fit inside a tight hallway closet or low-headroom utility room?

Bosch TR7000T-65US requires room for its 45.5 in. vertical shell and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Bosch TR7000T-65US?

For Bosch TR7000T-65US, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Bosch TR7000T-65US?

Using 1,240 kWh/yr, Bosch TR7000T-65US generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Bosch TR7000T-65US (3.9 UEF)?

Bosch TR7000T-65US requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Custom Comfort CCOHPWH65A.

What hot-water delivery rating governs Bosch TR7000T-65US?

Rated for 80 gal FHR (+8 gal vs. 72 gal median), Bosch TR7000T-65US prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Bosch TR7000T-65US for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Bosch; use our browser-only serial decoder to inspect Bosch TR7000T-65US's age and warranty window.

What alternative models sit closest to Bosch TR7000T-65US in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Custom Comfort CCOHPWH65A (3.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks