Bosch TR7000T-65US Water Heater Specifications (3.9 UEF)
Certified at 3.9 UEF across its 60-gallon nominal tank, 80 gal First Hour Rating, Bosch TR7000T-65US (Hybrid/Electric Heat Pump, Electric) places #144 of 706 out of 706 ENERGY STAR models (PD 3722796). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.40 / +56.0%. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Custom Comfort CCOHPWH65A (3.9 UEF).
- Uniform Energy Factor
- 3.9 UEF
- Cohort UEF Rank
- #144 of 706 (top 22.9%)
- First Hour Rating
- 80 gal
- Storage Volume
- 60 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.40 / +56.0%

Tested at 3.9 UEF, Bosch TR7000T-65US places #144 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.20 UEF vs. 3.70 UEF median).
Bosch TR7000T-65US clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.40 UEF (+56.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Bosch TR7000T-65US runs ~$225/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Bosch TR7000T-65US: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Bosch TR7000T-65US include Custom Comfort CCOHPWH65A (3.9 UEF, at parity) alongside Eco-Logical ECO-65HPM1A (3.9 UEF, at parity).
Which Specs Set Bosch TR7000T-65US Apart From Cohort Averages?
Ranked #144 of 706 (top 22.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, Bosch TR7000T-65US is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Bosch | 12 certified listings | ENERGY STAR PD 3722796 |
| Model Number | TR7000T-65US | Draw pattern: High-Usage | TR7000T-65US |
| Uniform Energy Factor (UEF) | 3.9 | +0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 80 gal | +8 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,240 kWh/yr | +168 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.5" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2025-01-16 | Certified 2025-01-16 | Markets: United States |
How Do Regional kWh Prices Impact TR7000T-65US Over 10 Years?
Using EIA Table 5.6.A benchmarks, Bosch TR7000T-65US's 1,240 kWh/yr draw translates to roughly $225/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,252 | $7,295 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $585/yr | $5,850 | $18,952 |
| California | 29.75 ¢/kWh ($0.2975) | $369/yr | $3,689 | $11,951 |
| Texas | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,973 | $6,391 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,814 | $5,877 |
What Should Bosch Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Bosch; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Custom Comfort CCOHPWH65A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Eco-Logical ECO-65HPM1A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Kepler AZMCHW-65VN3A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Midea CAN3-RSJ-15/250RDVN3-L3 | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
| Midea MAHW-65VN3A | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (at parity) | 1,240 |
Who Is Bosch TR7000T-65US Best For — and When Should You Pick Custom Comfort CCOHPWH65A?
Evaluate whether Bosch TR7000T-65US's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Bosch TR7000T-65US needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Bosch TR7000T-65US directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Bosch TR7000T-65US
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Bosch TR7000T-65US (3.9 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Bosch TR7000T-65US records 3.9 UEF (Pass: +1.40 / +56.0%), placing #144 of 706 (top 22.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Bosch TR7000T-65US fit inside a tight hallway closet or low-headroom utility room?
Bosch TR7000T-65US requires room for its 45.5 in. vertical shell and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Bosch TR7000T-65US?
For Bosch TR7000T-65US, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Bosch TR7000T-65US?
Using 1,240 kWh/yr, Bosch TR7000T-65US generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Bosch TR7000T-65US (3.9 UEF)?
Bosch TR7000T-65US requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Custom Comfort CCOHPWH65A.
What hot-water delivery rating governs Bosch TR7000T-65US?
Rated for 80 gal FHR (+8 gal vs. 72 gal median), Bosch TR7000T-65US prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Bosch TR7000T-65US for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Bosch; use our browser-only serial decoder to inspect Bosch TR7000T-65US's age and warranty window.
What alternative models sit closest to Bosch TR7000T-65US in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Custom Comfort CCOHPWH65A (3.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)