Eco-Logical OMNI-50HP1-1A Water Heater Specifications (3.3 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Eco-Logical OMNI-50HP1-1A (Electric) achieves a certified 3.3 UEF rating across its 46-gallon nominal tank, 50 gal First Hour Rating (rank #644 of 706, PD 4470524) and verifies as Pass: +1.00 / +43.5% for 2029 DOE floors. Rated annual electricity draw of 681 kWh/yr equates to roughly $124/yr ($1,237 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-50 1** (3.35 UEF).
- Uniform Energy Factor
- 3.3 UEF
- Cohort UEF Rank
- #644 of 706
- First Hour Rating
- 50 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.00 / +43.5%

Eco-Logical OMNI-50HP1-1A records 3.3 UEF efficiency, putting it #644 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Eco-Logical OMNI-50HP1-1A exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.00 UEF (+43.5%). At EIA August 2026 national rates (18.16 cents/kWh), 681 kWh/yr for Eco-Logical OMNI-50HP1-1A runs ~$124/yr vs. ~$444/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Eco-Logical OMNI-50HP1-1A: 10-year operating spend spans $996 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,213 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Eco-Logical OMNI-50HP1-1A (3.3 UEF) are A. O. Smith FPTU-50 1** (3.35 UEF, delta +0.05) and American HPHE6250H045DV 1** (3.35 UEF, delta +0.05).
Which Specs Set Eco-Logical OMNI-50HP1-1A Apart From Cohort Averages?
Ranked #644 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Eco-Logical OMNI-50HP1-1A is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Eco-Logical | 6 certified listings | ENERGY STAR PD 4470524 |
| Model Number | OMNI-50HP1-1A | Draw pattern: Low-Usage | OMNI-50HP1-1A |
| Uniform Energy Factor (UEF) | 3.3 | -0.40 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 50 gal | -22 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 681 kWh/yr | -391 kWh/yr vs. 1,072 kWh/yr median | Est. $124/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 431% | +2.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 72.7" H x 16.1" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (16.1" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 14.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-04 | Certified 2025-07-04 | Markets: United States, Canada |
How Do Regional kWh Prices Impact OMNI-50HP1-1A Over 10 Years?
Using EIA Table 5.6.A benchmarks, Eco-Logical OMNI-50HP1-1A's 681 kWh/yr draw translates to roughly $124/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $124/yr | $1,237 | $3,200 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $321/yr | $3,213 | $8,313 |
| California | 29.75 ¢/kWh ($0.2975) | $203/yr | $2,026 | $5,242 |
| Texas | 15.91 ¢/kWh ($0.1591) | $108/yr | $1,083 | $2,803 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $100/yr | $996 | $2,578 |
What Should Eco-Logical Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Eco-Logical; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith FPTU-50 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
| American HPHE6250H045DV 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
| RELIANCE WATER HEATERS 6-50-DHPHT 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
| State HP6-50-DHPT 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
| U.S. Craftmaster HPHE2F50HD045VU 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
When Should Homeowners Skip Eco-Logical OMNI-50HP1-1A (Hybrid/Electric Heat Pump)?
Check Eco-Logical OMNI-50HP1-1A's mechanical constraints—including utility space, Electric capacity, and Pass: +1.00 / +43.5% status—against typical residential installations.
Key Limitations & Exclusions
- Eco-Logical OMNI-50HP1-1A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Eco-Logical OMNI-50HP1-1A directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Eco-Logical OMNI-50HP1-1A
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Eco-Logical OMNI-50HP1-1A stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.3 UEF, Eco-Logical OMNI-50HP1-1A shows Pass: +1.00 / +43.5% relative to May 6, 2029 federal DOE limits while placing #644 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith FPTU-50 1**.
Will Eco-Logical OMNI-50HP1-1A fit through a standard utility door and 72-inch basement ceiling?
Measuring 72.7 in. tall by 16.1 in. diameter, Eco-Logical OMNI-50HP1-1A notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (16.1" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Eco-Logical OMNI-50HP1-1A during replacement?
Electrical specs for Eco-Logical OMNI-50HP1-1A call for 120V at 14.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Eco-Logical OMNI-50HP1-1A?
At 18.16 cents/kWh national residential pricing, Eco-Logical OMNI-50HP1-1A's 681 kWh/yr draw equals roughly $124 annually or $1,240 across a 10-year horizon (ranging from $100/yr in Washington hydro tiers up to $321/yr in Hawaii).
When is Eco-Logical OMNI-50HP1-1A a poor fit for a residential replacement?
Avoid placing Eco-Logical OMNI-50HP1-1A directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Eco-Logical OMNI-50HP1-1A deliver?
With 50 gal FHR (-22 gal vs. 72 gal median), Eco-Logical OMNI-50HP1-1A fits 1–3 person or moderate-draw homes cleanly.
How do you verify manufacturing age and recall status on Eco-Logical OMNI-50HP1-1A?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Eco-Logical; verify exact manufacturing week for Eco-Logical OMNI-50HP1-1A using the Serial Number Lookup tool.
Does Eco-Logical OMNI-50HP1-1A qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Eco-Logical OMNI-50HP1-1A. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-50 1** (3.35 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)