RELIANCE WATER HEATERS 6-50-DHPHT 1** Water Heater Specifications (3.35 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, RELIANCE WATER HEATERS 6-50-DHPHT 1** (Electric) achieves a certified 3.35 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating (rank #635 of 706, PD 2408904) and verifies as Pass: +1.05 / +45.7% for 2029 DOE floors. Rated annual electricity draw of 970 kWh/yr equates to roughly $176/yr ($1,762 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-50 1** (3.35 UEF).
- Uniform Energy Factor
- 3.35 UEF
- Cohort UEF Rank
- #635 of 706
- First Hour Rating
- 66 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.05 / +45.7%

RELIANCE WATER HEATERS 6-50-DHPHT 1** records 3.35 UEF efficiency, putting it #635 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: RELIANCE WATER HEATERS 6-50-DHPHT 1** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.05 UEF (+45.7%). At EIA August 2026 national rates (18.16 cents/kWh), 970 kWh/yr for RELIANCE WATER HEATERS 6-50-DHPHT 1** runs ~$176/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for RELIANCE WATER HEATERS 6-50-DHPHT 1**: 10-year operating spend spans $1,419 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,576 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside RELIANCE WATER HEATERS 6-50-DHPHT 1** (3.35 UEF) are A. O. Smith FPTU-50 1** (3.35 UEF, at parity) and American HPHE6250H045DV 1** (3.35 UEF, at parity).
Which Specs Set RELIANCE WATER HEATERS 6-50-DHPHT 1** Apart From Cohort Averages?
Ranked #635 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, RELIANCE WATER HEATERS 6-50-DHPHT 1** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | RELIANCE WATER HEATERS | 71 certified listings | ENERGY STAR PD 2408904 |
| Model Number | 6-50-DHPHT 1** | Draw pattern: Medium-Usage | 6-50-DHPHT 1** |
| Uniform Energy Factor (UEF) | 3.35 | -0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 66 gal | -6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 970 kWh/yr | -102 kWh/yr vs. 1,072 kWh/yr median | Est. $176/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |
How Do Regional kWh Prices Impact 6-50-DHPHT 1** Over 10 Years?
Using EIA Table 5.6.A benchmarks, RELIANCE WATER HEATERS 6-50-DHPHT 1**'s 970 kWh/yr draw translates to roughly $176/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $176/yr | $1,762 | $4,653 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $458/yr | $4,576 | $12,088 |
| California | 29.75 ¢/kWh ($0.2975) | $289/yr | $2,886 | $7,622 |
| Texas | 15.91 ¢/kWh ($0.1591) | $154/yr | $1,543 | $4,076 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $142/yr | $1,419 | $3,748 |
What Should RELIANCE WATER HEATERS Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 3 filings tied to RELIANCE WATER HEATERS; verify whether your 6-50-DHPHT 1** production run falls inside affected ranges. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith FPTU-50 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (at parity) | 970 |
| American HPHE6250H045DV 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (at parity) | 970 |
| State HP6-50-DHPT 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (at parity) | 970 |
| U.S. Craftmaster HPHE2F50HD045VU 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (at parity) | 970 |
| Eco-Logical OMNI-50HP1-1A | Hybrid/Electric Heat Pump | 46 gal | 50 gal | 3.3 (-0.05) | 681 |
What Are the Limitations of RELIANCE WATER HEATERS 6-50-DHPHT 1** and Who Should Not Install It?
Before ordering RELIANCE WATER HEATERS 6-50-DHPHT 1** (Hybrid/Electric Heat Pump, 3.35 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- RELIANCE WATER HEATERS 6-50-DHPHT 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 6-50-DHPHT 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: RELIANCE WATER HEATERS 6-50-DHPHT 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does RELIANCE WATER HEATERS 6-50-DHPHT 1** pass the May 6, 2029 federal DOE efficiency rule?
RELIANCE WATER HEATERS 6-50-DHPHT 1** carries a verified 3.35 UEF rating (Pass: +1.05 / +45.7%), ranking #635 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does RELIANCE WATER HEATERS 6-50-DHPHT 1** need?
RELIANCE WATER HEATERS 6-50-DHPHT 1** stands 63 in. high with a 15 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does RELIANCE WATER HEATERS 6-50-DHPHT 1** require?
RELIANCE WATER HEATERS 6-50-DHPHT 1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does RELIANCE WATER HEATERS 6-50-DHPHT 1** cost per year to run?
Rated at 970 kWh/yr, RELIANCE WATER HEATERS 6-50-DHPHT 1** costs about $176/yr ($1,760 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $142/yr in Washington hydro tiers up to $458/yr in Hawaii).
Who should NOT install RELIANCE WATER HEATERS 6-50-DHPHT 1**, and what are its limits?
RELIANCE WATER HEATERS 6-50-DHPHT 1** (3.35 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can RELIANCE WATER HEATERS 6-50-DHPHT 1** serve at peak demand?
RELIANCE WATER HEATERS 6-50-DHPHT 1** achieves a 66 gal First Hour Rating (-6 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for RELIANCE WATER HEATERS 6-50-DHPHT 1**?
CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to RELIANCE WATER HEATERS 6-50-DHPHT 1**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-50 1** (3.35 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)