Skip to main content
ENERGY STAR water heater model · PD 3555202

Friedrich 12PROG 40-50P FD HE EC3 Water Heater Specifications (0.9 UEF)

Engineered as a Propane Gas Storage unit, Friedrich 12PROG 40-50P FD HE EC3 achieves a certified 0.9 UEF rating across its 40-gallon nominal tank, 88 gal First Hour Rating and ranks #1 of 71 in its 71-model cohort (PD 3555202), recording Pass: +0.32 / +55.2% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Rheem ECE G40-50U CN HE* (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
88 gal
Storage Volume
40 gal
Fuel / Type
Propane / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking Friedrich 12PROG 40-50P FD HE EC3 at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58Friedrich 12PROG 40-50P FD HE EC3: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Friedrich 12PROG 40-50P FD HE EC3 relative to the cohort median.
Efficiency comparison & rule summary

Within the 71-unit Gas Storage cohort, Friedrich 12PROG 40-50P FD HE EC3 logs 0.9 UEF and ranks #1 of 71.

Friedrich 12prog 40-50p fd he ec3 stores 40 gal nominal; 88 gal first hour rating (-7 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d).

Cross-shopping Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF)? Check Rheem ECE G40-50U CN HE* (0.9 UEF, at parity) and Richmond 12GUH40-50F* (0.9 UEF, at parity).

What Physical and Thermal Ratings Define Friedrich 12PROG 40-50P FD HE EC3?

Positioning at #1 of 71 out of 71 Gas Storage peers, Friedrich 12PROG 40-50P FD HE EC3 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3555202
Model Number12PROG 40-50P FD HE EC3Draw pattern: High-Usage12PROG 40-50P FD HE EC3
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)88 gal-7 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency97%+3.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)54.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-04Certified 2024-11-04Markets: United States

Have Any Friedrich Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Friedrich; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Friedrich 12PROG 40-50P FD HE EC3?

Homeowners cross-shopping Friedrich 12PROG 40-50P FD HE EC3 frequently review these five Gas Storage models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem ECE G40-50U CN HE* Gas Storage 40 gal 88 gal 0.9 (at parity) —
Richmond 12GUH40-50F* Gas Storage 40 gal 88 gal 0.9 (at parity) —
Ruud PRO+G40-50P RU HE EC1 Gas Storage 40 gal 88 gal 0.9 (at parity) —
A. O. Smith GC6-PS4050*V 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Rheem PRO+G40-50P RH HE EC1 Gas Storage 40 gal 88 gal 0.9 (at parity) —

What Installation Caveats Apply Before Buying Friedrich 12PROG 40-50P FD HE EC3?

Even high-UEF units like Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Friedrich 12PROG 40-50P FD HE EC3 logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Friedrich 12PROG 40-50P FD HE EC3's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 88 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Friedrich 12PROG 40-50P FD HE EC3 Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Rheem ECE G40-50U CN HE*.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Sizing, Efficiency & Recall Answers for Friedrich 12PROG 40-50P FD HE EC3

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Friedrich 12PROG 40-50P FD HE EC3 eligible for continued manufacture past May 6, 2029?

At 0.9 UEF, Friedrich 12PROG 40-50P FD HE EC3 achieves Pass: +0.32 / +55.2% for the 2029 DOE standard and stands #1 of 71 against Rheem ECE G40-50U CN HE* and Richmond 12GUH40-50F*.

How tall and wide is Friedrich 12PROG 40-50P FD HE EC3, and what service clearance is needed?

Physical dimensions for Friedrich 12PROG 40-50P FD HE EC3 are 54.5 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

Will Friedrich 12PROG 40-50P FD HE EC3 require upgrading household electrical panels or gas piping?

Check Propane piping and venting for Friedrich 12PROG 40-50P FD HE EC3 (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is Friedrich 12PROG 40-50P FD HE EC3 economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Friedrich 12PROG 40-50P FD HE EC3 (Propane, 0.9 UEF) hinge on household gallon demand and local gas utility tariffs compared with Rheem ECE G40-50U CN HE*.

Which installation bottlenecks limit Friedrich 12PROG 40-50P FD HE EC3?

Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.32 / +55.2%) and physical doorway clearances before choosing Friedrich 12PROG 40-50P FD HE EC3 over Rheem ECE G40-50U CN HE*.

How does Friedrich 12PROG 40-50P FD HE EC3 handle simultaneous showers and laundry?

Delivering 88 gal in the first hour (-7 gal vs. 95 gal median), Friedrich 12PROG 40-50P FD HE EC3 combines 40 gal tank storage with rapid burner/element recovery.

How long is the warranty on Friedrich 12PROG 40-50P FD HE EC3 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Friedrich as of 2026-11-23. Confirm install proof and serial manufacture year on Friedrich 12PROG 40-50P FD HE EC3 before calling service.

How do 2026 post-OBBBA rebates affect buying Friedrich 12PROG 40-50P FD HE EC3?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Storage is Rheem ECE G40-50U CN HE* (0.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks