Rheem PRO+G40-50P RH HE EC1 Water Heater Specifications (0.9 UEF)
With PD 3387603 certification, Rheem PRO+G40-50P RH HE EC1 (Gas Storage, Propane) achieves a certified 0.9 UEF rating across its 40-gallon nominal tank, 88 gal First Hour Rating, standing #1 of 71 across 71 peers with Pass: +0.32 / +55.2% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).
- Uniform Energy Factor
- 0.9 UEF
- Cohort UEF Rank
- #1 of 71
- First Hour Rating
- 88 gal
- Storage Volume
- 40 gal
- Fuel / Type
- Propane / Gas Storage
- DOE 2029 Rule Status
- Pass: +0.32 / +55.2%

ENERGY STAR certification places Rheem PRO+G40-50P RH HE EC1 at 0.9 UEF (#1 of 71; At 0.90 UEF median) in Gas Storage.
Rheem pro+g40-50p rh he ec1 stores 40 gal nominal; 88 gal first hour rating (-7 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d).
In the Gas Storage tier, Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF, at parity) and Richmond 12GUH40-50F* (0.9 UEF, at parity) bracket Rheem PRO+G40-50P RH HE EC1.
What Physical and Thermal Ratings Define Rheem PRO+G40-50P RH HE EC1?
Positioning at #1 of 71 out of 71 Gas Storage peers, Rheem PRO+G40-50P RH HE EC1 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3387603 |
| Model Number | PRO+G40-50P RH HE EC1 | Draw pattern: High-Usage | PRO+G40-50P RH HE EC1 |
| Uniform Energy Factor (UEF) | 0.9 | At 0.90 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 88 gal | -7 gal vs. 95 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +3.0 pts vs. 94.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 54.5" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-04 | Certified 2024-11-04 | Markets: United States |
Have Any Rheem Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to Rheem PRO+G40-50P RH HE EC1?
Homeowners cross-shopping Rheem PRO+G40-50P RH HE EC1 frequently review these five Gas Storage models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich 12PROG 40-50P FD HE EC3 | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| Richmond 12GUH40-50F* | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| Ruud PRO+G40-50P RU HE EC1 | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| A. O. Smith GC6-PS4050*V 1** | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| Friedrich 12PROG 40-50U FD HE EC3 | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
What Installation Caveats Apply Before Buying Rheem PRO+G40-50P RH HE EC1?
Even high-UEF units like Rheem PRO+G40-50P RH HE EC1 (0.9 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Rheem PRO+G40-50P RH HE EC1 logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Rheem PRO+G40-50P RH HE EC1's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 88 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Rheem PRO+G40-50P RH HE EC1
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Rheem PRO+G40-50P RH HE EC1 eligible for continued manufacture past May 6, 2029?
At 0.9 UEF, Rheem PRO+G40-50P RH HE EC1 achieves Pass: +0.32 / +55.2% for the 2029 DOE standard and stands #1 of 71 against Friedrich 12PROG 40-50P FD HE EC3 and Richmond 12GUH40-50F*.
How tall and wide is Rheem PRO+G40-50P RH HE EC1, and what service clearance is needed?
Physical dimensions for Rheem PRO+G40-50P RH HE EC1 are 54.5 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.
Will Rheem PRO+G40-50P RH HE EC1 require upgrading household electrical panels or gas piping?
Check Propane piping and venting for Rheem PRO+G40-50P RH HE EC1 (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.
Is Rheem PRO+G40-50P RH HE EC1 economical to operate at 18.16 cents/kWh US electric rates?
Fuel bills for Rheem PRO+G40-50P RH HE EC1 (Propane, 0.9 UEF) hinge on household gallon demand and local gas utility tariffs compared with Friedrich 12PROG 40-50P FD HE EC3.
Which installation bottlenecks limit Rheem PRO+G40-50P RH HE EC1?
Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.32 / +55.2%) and physical doorway clearances before choosing Rheem PRO+G40-50P RH HE EC1 over Friedrich 12PROG 40-50P FD HE EC3.
How does Rheem PRO+G40-50P RH HE EC1 handle simultaneous showers and laundry?
Delivering 88 gal in the first hour (-7 gal vs. 95 gal median), Rheem PRO+G40-50P RH HE EC1 combines 40 gal tank storage with rapid burner/element recovery.
How long is the warranty on Rheem PRO+G40-50P RH HE EC1 and how do you decode its serial?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying Rheem PRO+G40-50P RH HE EC1?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Storage is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)