Skip to main content
ENERGY STAR water heater model · PD 3555205

Friedrich 8PROG 40-50U FD HE EC1 Water Heater Specifications (0.9 UEF)

The Friedrich 8PROG 40-50U FD HE EC1 (Gas Storage, Natural Gas) achieves a certified 0.9 UEF rating across its 40-gallon nominal tank, 88 gal First Hour Rating, ranking #1 of 71 among 71 ENERGY STAR Gas Storage models (PD 3555205). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.32 / +55.2%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Rheem ECE G40-50U CN HE* (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
88 gal
Storage Volume
40 gal
Fuel / Type
Natural Gas / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking Friedrich 8PROG 40-50U FD HE EC1 at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58Friedrich 8PROG 40-50U FD HE EC1: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Friedrich 8PROG 40-50U FD HE EC1 relative to the cohort median.
Efficiency comparison & rule summary

Friedrich 8PROG 40-50U FD HE EC1 (0.9 UEF) ranks #1 of 71 Gas Storage models — 51-way tie; more efficient than 28.2% of Gas Storage models, at the 0.90 UEF median.

Friedrich 8prog 40-50u fd he ec1 stores 40 gal nominal; 88 gal first hour rating (-7 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d).

Peer comparison: Friedrich 8PROG 40-50U FD HE EC1 (0.9 UEF) compares closely with Rheem ECE G40-50U CN HE* (0.9 UEF, at parity) and Richmond 12GUH40-50F* (0.9 UEF, at parity).

Which Specs Set Friedrich 8PROG 40-50U FD HE EC1 Apart From Cohort Averages?

Ranked #1 of 71 inside the 71-model Gas Storage cohort, Friedrich 8PROG 40-50U FD HE EC1 is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3555205
Model Number8PROG 40-50U FD HE EC1Draw pattern: High-Usage8PROG 40-50U FD HE EC1
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)88 gal-7 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency97%+3.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)54.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-04Certified 2024-11-04Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Friedrich Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Friedrich; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Gas Storage Models Stack Up?

Five alternative Gas Storage units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem ECE G40-50U CN HE* Gas Storage 40 gal 88 gal 0.9 (at parity) —
Richmond 12GUH40-50F* Gas Storage 40 gal 88 gal 0.9 (at parity) —
Ruud PRO+G40-50P RU HE EC1 Gas Storage 40 gal 88 gal 0.9 (at parity) —
A. O. Smith GC6-PS4050*V 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Rheem PRO+G40-50P RH HE EC1 Gas Storage 40 gal 88 gal 0.9 (at parity) —

Who Is Friedrich 8PROG 40-50U FD HE EC1 Best For — and When Should You Pick Rheem ECE G40-50U CN HE*?

Evaluate whether Friedrich 8PROG 40-50U FD HE EC1's Gas Storage architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Friedrich 8PROG 40-50U FD HE EC1 logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Friedrich 8PROG 40-50U FD HE EC1's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 88 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Friedrich 8PROG 40-50U FD HE EC1 Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Rheem ECE G40-50U CN HE*.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Frequently Asked Technical Questions: Friedrich 8PROG 40-50U FD HE EC1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Friedrich 8PROG 40-50U FD HE EC1 (0.9 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Friedrich 8PROG 40-50U FD HE EC1 records 0.9 UEF (Pass: +0.32 / +55.2%), placing #1 of 71 out of 71 certified Gas Storage configurations.

Does Friedrich 8PROG 40-50U FD HE EC1 fit inside a tight hallway closet or low-headroom utility room?

Friedrich 8PROG 40-50U FD HE EC1 requires room for its 54.5 in. vertical shell and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Friedrich 8PROG 40-50U FD HE EC1?

Installing Friedrich 8PROG 40-50U FD HE EC1 on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for Friedrich 8PROG 40-50U FD HE EC1?

Rated 0.9 UEF on Natural Gas, Friedrich 8PROG 40-50U FD HE EC1 carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas Storage models.

What are the main drawbacks of Friedrich 8PROG 40-50U FD HE EC1 (0.9 UEF)?

Buyers expecting endless simultaneous shower flow beyond 88 gal should compare condensing tankless units or larger-capacity tanks.

What hot-water delivery rating governs Friedrich 8PROG 40-50U FD HE EC1?

Rated for 88 gal FHR (-7 gal vs. 95 gal median), Friedrich 8PROG 40-50U FD HE EC1 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Friedrich 8PROG 40-50U FD HE EC1 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Friedrich; use our browser-only serial decoder to inspect Friedrich 8PROG 40-50U FD HE EC1's age and warranty window.

What alternative models sit closest to Friedrich 8PROG 40-50U FD HE EC1 in the Gas Storage class?

Closest peer in Gas Storage is Rheem ECE G40-50U CN HE* (0.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks