Skip to main content
ENERGY STAR water heater model · PD 3845909

Friedrich PROH40 T0 FD120-M Water Heater Specifications (2.8 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Friedrich PROH40 T0 FD120-M (Electric) achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal First Hour Rating (rank #695 of 706, PD 3845909) and verifies as Pass: +0.50 / +21.7% for 2029 DOE floors. Rated annual electricity draw of 780 kWh/yr equates to roughly $142/yr ($1,416 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem PROPH40 T0 RH120-M (2.8 UEF).

Uniform Energy Factor
2.8 UEF
Cohort UEF Rank
#695 of 706
First Hour Rating
45 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.50 / +21.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Friedrich PROH40 T0 FD120-M at 2.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Friedrich PROH40 T0 FD120-M: 2.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH40 T0 FD120-M relative to the cohort median.
Efficiency comparison & rule summary

Friedrich PROH40 T0 FD120-M records 2.8 UEF efficiency, putting it #695 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Friedrich PROH40 T0 FD120-M exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +0.50 UEF (+21.7%). At EIA August 2026 national rates (18.16 cents/kWh), 780 kWh/yr for Friedrich PROH40 T0 FD120-M runs ~$142/yr vs. ~$431/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH40 T0 FD120-M: 10-year operating spend spans $1,141 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,680 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Friedrich PROH40 T0 FD120-M (2.8 UEF) are Rheem PROPH40 T0 RH120-M (2.8 UEF, at parity) and Richmond 10E40-HP120M (2.8 UEF, at parity).

What Physical and Thermal Ratings Define Friedrich PROH40 T0 FD120-M?

Positioning at #695 of 706 out of 706 Hybrid/Electric Heat Pump peers, Friedrich PROH40 T0 FD120-M pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3845909
Model NumberPROH40 T0 FD120-MDraw pattern: Low-UsagePROH40 T0 FD120-M
Uniform Energy Factor (UEF)2.8-0.90 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)45 gal-27 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use780 kWh/yr-292 kWh/yr vs. 1,072 kWh/yr medianEst. $142/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency387%-42.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.5" H x 16" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 4.5 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States

Why Do State Utility Rates Shift PROH40 T0 FD120-M Running Costs?

Consuming 780 kWh annually puts Friedrich PROH40 T0 FD120-M near $142/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (780 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$142.00/yrHawaii$368.00/yrCalifornia$232.00/yrTexas$124.00/yrWashington$114.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $142/yr $1,416 $2,895
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $368/yr $3,680 $7,520
California 29.75 ¢/kWh ($0.2975) $232/yr $2,320 $4,742
Texas 15.91 ¢/kWh ($0.1591) $124/yr $1,241 $2,536
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $114/yr $1,141 $2,332
Estimated electricity spend (780 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Friedrich Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Friedrich; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Friedrich PROH40 T0 FD120-M?

Homeowners cross-shopping Friedrich PROH40 T0 FD120-M frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem PROPH40 T0 RH120-M Hybrid/Electric Heat Pump 36 gal 45 gal 2.8 (at parity) 780
Richmond 10E40-HP120M Hybrid/Electric Heat Pump 36 gal 45 gal 2.8 (at parity) 780
Ruud PROUH40 T0 RU120-M Hybrid/Electric Heat Pump 36 gal 45 gal 2.8 (at parity) 780
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (+0.80) 902
Rheem PROPH40 T0 RH120-MSO Hybrid/Electric Heat Pump 36 gal 45 gal 2.8 (at parity) 780

What Are the Limitations of Friedrich PROH40 T0 FD120-M and Who Should Not Install It?

Before ordering Friedrich PROH40 T0 FD120-M (Hybrid/Electric Heat Pump, 2.8 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Friedrich PROH40 T0 FD120-M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Friedrich PROH40 T0 FD120-M directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Friedrich PROH40 T0 FD120-M Strong Fit — 2.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rheem PROPH40 T0 RH120-M footprint.

Sizing, Efficiency & Recall Answers for Friedrich PROH40 T0 FD120-M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Friedrich PROH40 T0 FD120-M pass the May 6, 2029 federal DOE efficiency rule?

Friedrich PROH40 T0 FD120-M carries a verified 2.8 UEF rating (Pass: +0.50 / +21.7%), ranking #695 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Friedrich PROH40 T0 FD120-M need?

Friedrich PROH40 T0 FD120-M stands 45.5 in. high with a 16 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Friedrich PROH40 T0 FD120-M require?

Friedrich PROH40 T0 FD120-M uses a 120V branch circuit at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Friedrich PROH40 T0 FD120-M cost per year to run?

Rated at 780 kWh/yr, Friedrich PROH40 T0 FD120-M costs about $142/yr ($1,420 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $114/yr in Washington hydro tiers up to $368/yr in Hawaii).

Who should NOT install Friedrich PROH40 T0 FD120-M, and what are its limits?

Friedrich PROH40 T0 FD120-M (2.8 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Friedrich PROH40 T0 FD120-M serve at peak demand?

Friedrich PROH40 T0 FD120-M achieves a 45 gal First Hour Rating (-27 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Friedrich PROH40 T0 FD120-M?

No active CPSC recalls matched Friedrich as of 2026-11-23. Always decode the serial tag on Friedrich PROH40 T0 FD120-M because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Friedrich PROH40 T0 FD120-M, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Rheem PROPH40 T0 RH120-M (2.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks