Skip to main content
ENERGY STAR water heater model · PD 3555264

Richmond 10E40-HP120M Water Heater Specifications (2.8 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Richmond 10E40-HP120M (Electric) achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal First Hour Rating (rank #695 of 706, PD 3555264) and verifies as Pass: +0.50 / +21.7% for 2029 DOE floors. Rated annual electricity draw of 780 kWh/yr equates to roughly $142/yr ($1,416 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T0 FD120-M (2.8 UEF).

Uniform Energy Factor
2.8 UEF
Cohort UEF Rank
#695 of 706
First Hour Rating
45 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.50 / +21.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E40-HP120M at 2.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Richmond 10E40-HP120M: 2.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E40-HP120M relative to the cohort median.
Efficiency comparison & rule summary

Richmond 10E40-HP120M records 2.8 UEF efficiency, putting it #695 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Richmond 10E40-HP120M exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +0.50 UEF (+21.7%). At EIA August 2026 national rates (18.16 cents/kWh), 780 kWh/yr for Richmond 10E40-HP120M runs ~$142/yr vs. ~$431/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E40-HP120M: 10-year operating spend spans $1,141 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,680 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Richmond 10E40-HP120M (2.8 UEF) are Friedrich PROH40 T0 FD120-M (2.8 UEF, at parity) and Rheem PROPH40 T0 RH120-M (2.8 UEF, at parity).

Which Specs Set Richmond 10E40-HP120M Apart From Cohort Averages?

Ranked #695 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Richmond 10E40-HP120M is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3555264
Model Number10E40-HP120MDraw pattern: Low-Usage10E40-HP120M
Uniform Energy Factor (UEF)2.8-0.90 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)45 gal-27 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use780 kWh/yr-292 kWh/yr vs. 1,072 kWh/yr medianEst. $142/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency387%-42.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 4.5 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States

How Do Regional kWh Prices Impact 10E40-HP120M Over 10 Years?

Using EIA Table 5.6.A benchmarks, Richmond 10E40-HP120M's 780 kWh/yr draw translates to roughly $142/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (780 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$142.00/yrHawaii$368.00/yrCalifornia$232.00/yrTexas$124.00/yrWashington$114.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $142/yr $1,416 $2,895
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $368/yr $3,680 $7,520
California 29.75 ¢/kWh ($0.2975) $232/yr $2,320 $4,742
Texas 15.91 ¢/kWh ($0.1591) $124/yr $1,241 $2,536
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $114/yr $1,141 $2,332
Estimated electricity spend (780 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Richmond Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Richmond; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T0 FD120-M Hybrid/Electric Heat Pump 36 gal 45 gal 2.8 (at parity) 780
Rheem PROPH40 T0 RH120-M Hybrid/Electric Heat Pump 36 gal 45 gal 2.8 (at parity) 780
Ruud PROUH40 T0 RU120-M Hybrid/Electric Heat Pump 36 gal 45 gal 2.8 (at parity) 780
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (+0.80) 902
Friedrich PROH40 T0 FD120-MSO Hybrid/Electric Heat Pump 36 gal 45 gal 2.8 (at parity) 780

Which Home Setups Are NOT a Fit for Richmond 10E40-HP120M?

Comparing Richmond 10E40-HP120M against Friedrich PROH40 T0 FD120-M requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Richmond 10E40-HP120M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E40-HP120M directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E40-HP120M Strong Fit — 2.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T0 FD120-M footprint.

Frequently Asked Technical Questions: Richmond 10E40-HP120M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Richmond 10E40-HP120M score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Richmond 10E40-HP120M logs 2.8 UEF (Pass: +0.50 / +21.7%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Richmond 10E40-HP120M?

With a 62.3 in. height and 20.3 in. diameter, Richmond 10E40-HP120M fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Richmond 10E40-HP120M?

Powered via 120V at 4.5A max, Richmond 10E40-HP120M requires: 120V plug-in retrofit circuit; slower heat-pump-only recovery. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Richmond 10E40-HP120M?

Annual electric spend for Richmond 10E40-HP120M (780 kWh/yr) averages $142/yr nationwide (ranging from $114/yr in Washington hydro tiers up to $368/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Richmond 10E40-HP120M?

Homes lacking a condensate drain or 120V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Richmond 10E40-HP120M.

Is Richmond 10E40-HP120M sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Richmond 10E40-HP120M at 45 gal First Hour Rating (-27 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Richmond have active CPSC SaferProducts notices affecting 10E40-HP120M?

Zero CPSC recall alerts matched Richmond (2026-11-23 check). Keep your Richmond 10E40-HP120M serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Richmond 10E40-HP120M (2.8 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Richmond 10E40-HP120M. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T0 FD120-M (2.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks