Friedrich PROH40 T0 FD120-MSO Water Heater Specifications (2.8 UEF)
The Friedrich PROH40 T0 FD120-MSO (Hybrid/Electric Heat Pump, Electric) achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal First Hour Rating, ranking #695 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3845910). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.50 / +21.7%. Rated annual electricity draw of 780 kWh/yr equates to roughly $142/yr ($1,416 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem PROPH40 T0 RH120-M (2.8 UEF).
- Uniform Energy Factor
- 2.8 UEF
- Cohort UEF Rank
- #695 of 706
- First Hour Rating
- 45 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.50 / +21.7%

Friedrich PROH40 T0 FD120-MSO (2.8 UEF) ranks #695 of 706 Hybrid/Electric Heat Pump models — 10-way tie; more efficient than 0.3% of Hybrid/Electric Heat Pump models, -0.90 UEF below the 3.70 UEF median.
Federal 2029 margin for Friedrich PROH40 T0 FD120-MSO: +0.50 UEF (+21.7%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 780 kWh/yr for Friedrich PROH40 T0 FD120-MSO runs ~$142/yr vs. ~$431/yr for a 0.92 UEF electric tank.
State electric sensitivity for Friedrich PROH40 T0 FD120-MSO: 10-year operating spend spans $1,141 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,680 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Friedrich PROH40 T0 FD120-MSO (2.8 UEF) compares closely with Rheem PROPH40 T0 RH120-M (2.8 UEF, at parity) and Richmond 10E40-HP120M (2.8 UEF, at parity).
Which Specs Set Friedrich PROH40 T0 FD120-MSO Apart From Cohort Averages?
Ranked #695 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Friedrich PROH40 T0 FD120-MSO is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Friedrich | 61 certified listings | ENERGY STAR PD 3845910 |
| Model Number | PROH40 T0 FD120-MSO | Draw pattern: Low-Usage | PROH40 T0 FD120-MSO |
| Uniform Energy Factor (UEF) | 2.8 | -0.90 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 45 gal | -27 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 780 kWh/yr | -292 kWh/yr vs. 1,072 kWh/yr median | Est. $142/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 387% | -42.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.5" H x 16" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 4.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |
How Do Regional kWh Prices Impact PROH40 T0 FD120-MSO Over 10 Years?
Using EIA Table 5.6.A benchmarks, Friedrich PROH40 T0 FD120-MSO's 780 kWh/yr draw translates to roughly $142/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $142/yr | $1,416 | $2,895 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $368/yr | $3,680 | $7,520 |
| California | 29.75 ¢/kWh ($0.2975) | $232/yr | $2,320 | $4,742 |
| Texas | 15.91 ¢/kWh ($0.1591) | $124/yr | $1,241 | $2,536 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $114/yr | $1,141 | $2,332 |
What Should Friedrich Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Friedrich; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Rheem PROPH40 T0 RH120-M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| Richmond 10E40-HP120M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| Ruud PROUH40 T0 RU120-M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.80) | 902 |
| Rheem PROPH40 T0 RH120-MSO | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
When Should Homeowners Skip Friedrich PROH40 T0 FD120-MSO (Hybrid/Electric Heat Pump)?
Check Friedrich PROH40 T0 FD120-MSO's mechanical constraints—including utility space, Electric capacity, and Pass: +0.50 / +21.7% status—against typical residential installations.
Key Limitations & Exclusions
- Friedrich PROH40 T0 FD120-MSO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH40 T0 FD120-MSO directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Friedrich PROH40 T0 FD120-MSO
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Friedrich PROH40 T0 FD120-MSO stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 2.8 UEF, Friedrich PROH40 T0 FD120-MSO shows Pass: +0.50 / +21.7% relative to May 6, 2029 federal DOE limits while placing #695 of 706 among 706 Hybrid/Electric Heat Pump peers like Rheem PROPH40 T0 RH120-M.
Will Friedrich PROH40 T0 FD120-MSO fit through a standard utility door and 72-inch basement ceiling?
Measuring 45.5 in. tall by 16 in. diameter, Friedrich PROH40 T0 FD120-MSO notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Friedrich PROH40 T0 FD120-MSO during replacement?
Electrical specs for Friedrich PROH40 T0 FD120-MSO call for 120V at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Friedrich PROH40 T0 FD120-MSO?
At 18.16 cents/kWh national residential pricing, Friedrich PROH40 T0 FD120-MSO's 780 kWh/yr draw equals roughly $142 annually or $1,420 across a 10-year horizon (ranging from $114/yr in Washington hydro tiers up to $368/yr in Hawaii).
When is Friedrich PROH40 T0 FD120-MSO a poor fit for a residential replacement?
Avoid placing Friedrich PROH40 T0 FD120-MSO directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Friedrich PROH40 T0 FD120-MSO deliver?
With 45 gal FHR (-27 gal vs. 72 gal median), Friedrich PROH40 T0 FD120-MSO fits 1–3 person or moderate-draw homes cleanly.
How do you verify manufacturing age and recall status on Friedrich PROH40 T0 FD120-MSO?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Friedrich; verify exact manufacturing week for Friedrich PROH40 T0 FD120-MSO using the Serial Number Lookup tool.
Does Friedrich PROH40 T0 FD120-MSO qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Friedrich PROH40 T0 FD120-MSO. Closest peer in Hybrid/Electric Heat Pump is Rheem PROPH40 T0 RH120-M (2.8 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)