Skip to main content
ENERGY STAR water heater model · PD 3845908

Friedrich PROH50 T0 FD120 Water Heater Specifications (3 UEF)

With PD 3845908 certification, Friedrich PROH50 T0 FD120 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 51 gal First Hour Rating, standing #666 of 706 across 706 peers with Pass: +0.70 / +30.4% for May 6, 2029. Rated annual electricity draw of 1,082 kWh/yr equates to roughly $196/yr ($1,965 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem PROPH50 T0 RH120 (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
51 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +30.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Friedrich PROH50 T0 FD120 at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Friedrich PROH50 T0 FD120: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH50 T0 FD120 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Friedrich PROH50 T0 FD120 at 3.0 UEF (#666 of 706; -0.70 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Friedrich PROH50 T0 FD120 stands +0.70 UEF (+30.4%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,082 kWh/yr for Friedrich PROH50 T0 FD120 runs ~$196/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH50 T0 FD120: 10-year operating spend spans $1,583 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,105 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Rheem PROPH50 T0 RH120 (3.0 UEF, at parity) and Richmond 10E50-HP120 (3.0 UEF, at parity) bracket Friedrich PROH50 T0 FD120.

What Physical and Thermal Ratings Define Friedrich PROH50 T0 FD120?

Positioning at #666 of 706 out of 706 Hybrid/Electric Heat Pump peers, Friedrich PROH50 T0 FD120 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3845908
Model NumberPROH50 T0 FD120Draw pattern: Medium-UsagePROH50 T0 FD120
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)51 gal-21 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,082 kWh/yr+10 kWh/yr vs. 1,072 kWh/yr medianEst. $196/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency350%-79.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.3" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States

Why Do State Utility Rates Shift PROH50 T0 FD120 Running Costs?

Consuming 1,082 kWh annually puts Friedrich PROH50 T0 FD120 near $196/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,082 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$196.00/yrHawaii$510.00/yrCalifornia$322.00/yrTexas$172.00/yrWashington$158.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $196/yr $1,965 $4,442
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $510/yr $5,105 $11,540
California 29.75 ¢/kWh ($0.2975) $322/yr $3,219 $7,277
Texas 15.91 ¢/kWh ($0.1591) $172/yr $1,721 $3,892
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $158/yr $1,583 $3,578
Estimated electricity spend (1,082 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Friedrich Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Friedrich; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Friedrich PROH50 T0 FD120?

Homeowners cross-shopping Friedrich PROH50 T0 FD120 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem PROPH50 T0 RH120 Hybrid/Electric Heat Pump 46 gal 51 gal 3.0 (at parity) 1,082
Richmond 10E50-HP120 Hybrid/Electric Heat Pump 46 gal 51 gal 3.0 (at parity) 1,082
Ruud PROUH50 T0 RU120 Hybrid/Electric Heat Pump 46 gal 51 gal 3.0 (at parity) 1,082
A. O. Smith HPTV-50 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
Rheem XE50T10H15U0 Hybrid/Electric Heat Pump 46 gal 51 gal 3.0 (at parity) 1,082

Who Is Friedrich PROH50 T0 FD120 Best For — and When Should You Pick Rheem PROPH50 T0 RH120?

Evaluate whether Friedrich PROH50 T0 FD120's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Friedrich PROH50 T0 FD120 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Friedrich PROH50 T0 FD120 directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Friedrich PROH50 T0 FD120 Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rheem PROPH50 T0 RH120 footprint.

Sizing, Efficiency & Recall Answers for Friedrich PROH50 T0 FD120

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Friedrich PROH50 T0 FD120 (3.0 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Friedrich PROH50 T0 FD120 records 3.0 UEF (Pass: +0.70 / +30.4%), placing #666 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Friedrich PROH50 T0 FD120 fit inside a tight hallway closet or low-headroom utility room?

Friedrich PROH50 T0 FD120 requires room for its 45.3 in. vertical shell and 18 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Friedrich PROH50 T0 FD120?

For Friedrich PROH50 T0 FD120, plan a 120V circuit at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Friedrich PROH50 T0 FD120?

Using 1,082 kWh/yr, Friedrich PROH50 T0 FD120 generates an estimated $196/yr electric bill at 18.16 cents/kWh (ranging from $158/yr in Washington hydro tiers up to $510/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Friedrich PROH50 T0 FD120 (3.0 UEF)?

Friedrich PROH50 T0 FD120 requires >=450 cu ft air space, 120V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Rheem PROPH50 T0 RH120.

What hot-water delivery rating governs Friedrich PROH50 T0 FD120?

Rated for 51 gal FHR (-21 gal vs. 72 gal median), Friedrich PROH50 T0 FD120 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Friedrich PROH50 T0 FD120 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Friedrich; use our browser-only serial decoder to inspect Friedrich PROH50 T0 FD120's age and warranty window.

What alternative models sit closest to Friedrich PROH50 T0 FD120 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Rheem PROPH50 T0 RH120 (3.0 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks