Richmond 10E50-HP120 Water Heater Specifications (3 UEF)
With PD 2408488 certification, Richmond 10E50-HP120 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 51 gal First Hour Rating, standing #666 of 706 across 706 peers with Pass: +0.70 / +30.4% for May 6, 2029. Rated annual electricity draw of 1,082 kWh/yr equates to roughly $196/yr ($1,965 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T0 FD120 (3.0 UEF).
- Uniform Energy Factor
- 3.0 UEF
- Cohort UEF Rank
- #666 of 706
- First Hour Rating
- 51 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.70 / +30.4%

ENERGY STAR certification places Richmond 10E50-HP120 at 3.0 UEF (#666 of 706; -0.70 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Richmond 10E50-HP120 stands +0.70 UEF (+30.4%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,082 kWh/yr for Richmond 10E50-HP120 runs ~$196/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10E50-HP120: 10-year operating spend spans $1,583 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,105 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Friedrich PROH50 T0 FD120 (3.0 UEF, at parity) and Rheem PROPH50 T0 RH120 (3.0 UEF, at parity) bracket Richmond 10E50-HP120.
Where Does Richmond 10E50-HP120 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10E50-HP120 holds #666 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 2408488 |
| Model Number | 10E50-HP120 | Draw pattern: Medium-Usage | 10E50-HP120 |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 51 gal | -21 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,082 kWh/yr | +10 kWh/yr vs. 1,072 kWh/yr median | Est. $196/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 350% | -79.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 65" H x 22.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 15 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |
How Much Electricity Does 10E50-HP120 Use in Different States?
Estimated at $196/yr nationally (1,082 kWh/yr), 10-year utility spending for Richmond 10E50-HP120 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $196/yr | $1,965 | $4,442 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $510/yr | $5,105 | $11,540 |
| California | 29.75 ¢/kWh ($0.2975) | $322/yr | $3,219 | $7,277 |
| Texas | 15.91 ¢/kWh ($0.1591) | $172/yr | $1,721 | $3,892 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $158/yr | $1,583 | $3,578 |
Does CPSC Flag Any Safety Notices on Richmond Units?
No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10E50-HP120?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10E50-HP120's gallon capacity and 3.0 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH50 T0 FD120 | Hybrid/Electric Heat Pump | 46 gal | 51 gal | 3.0 (at parity) | 1,082 |
| Rheem PROPH50 T0 RH120 | Hybrid/Electric Heat Pump | 46 gal | 51 gal | 3.0 (at parity) | 1,082 |
| Ruud PROUH50 T0 RU120 | Hybrid/Electric Heat Pump | 46 gal | 51 gal | 3.0 (at parity) | 1,082 |
| A. O. Smith HPTV-50 2** | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| Rheem XE50T10H15U0 | Hybrid/Electric Heat Pump | 46 gal | 51 gal | 3.0 (at parity) | 1,082 |
When Should Homeowners Skip Richmond 10E50-HP120 (Hybrid/Electric Heat Pump)?
Check Richmond 10E50-HP120's mechanical constraints—including utility space, Electric capacity, and Pass: +0.70 / +30.4% status—against typical residential installations.
Key Limitations & Exclusions
- Richmond 10E50-HP120 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E50-HP120 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Richmond 10E50-HP120
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Richmond 10E50-HP120 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.0 UEF, Richmond 10E50-HP120 shows Pass: +0.70 / +30.4% relative to May 6, 2029 federal DOE limits while placing #666 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH50 T0 FD120.
Will Richmond 10E50-HP120 fit through a standard utility door and 72-inch basement ceiling?
Measuring 65 in. tall by 22.3 in. diameter, Richmond 10E50-HP120 notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (22.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Richmond 10E50-HP120 during replacement?
Electrical specs for Richmond 10E50-HP120 call for 120V at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Richmond 10E50-HP120?
At 18.16 cents/kWh national residential pricing, Richmond 10E50-HP120's 1,082 kWh/yr draw equals roughly $196 annually or $1,960 across a 10-year horizon (ranging from $158/yr in Washington hydro tiers up to $510/yr in Hawaii).
When is Richmond 10E50-HP120 a poor fit for a residential replacement?
Avoid placing Richmond 10E50-HP120 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Richmond 10E50-HP120 deliver?
With 51 gal FHR (-21 gal vs. 72 gal median), Richmond 10E50-HP120 fits 1–3 person or moderate-draw homes cleanly.
How do you verify manufacturing age and recall status on Richmond 10E50-HP120?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10E50-HP120 using the Serial Number Lookup tool.
Does Richmond 10E50-HP120 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10E50-HP120. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T0 FD120 (3.0 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)