Skip to main content
ENERGY STAR water heater model · PD 3845916

Friedrich PROH80 T0 FD120-MSO Water Heater Specifications (3.46 UEF)

Certified at 3.46 UEF across its 72-gallon nominal tank, 84 gal First Hour Rating, Friedrich PROH80 T0 FD120-MSO (Hybrid/Electric Heat Pump, Electric) places #549 of 706 out of 706 ENERGY STAR models (PD 3845916). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.96 / +38.4%. Rated annual electricity draw of 1,403 kWh/yr equates to roughly $255/yr ($2,548 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem PROPH80 T0 RH120-M (3.46 UEF).

Uniform Energy Factor
3.46 UEF
Cohort UEF Rank
#549 of 706
First Hour Rating
84 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.96 / +38.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Friedrich PROH80 T0 FD120-MSO at 3.46 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Friedrich PROH80 T0 FD120-MSO: 3.46
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH80 T0 FD120-MSO relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.46 UEF, Friedrich PROH80 T0 FD120-MSO places #549 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.24 UEF vs. 3.70 UEF median).

Friedrich PROH80 T0 FD120-MSO clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.96 UEF (+38.4% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,403 kWh/yr for Friedrich PROH80 T0 FD120-MSO runs ~$255/yr vs. ~$958/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH80 T0 FD120-MSO: 10-year operating spend spans $2,053 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,619 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Friedrich PROH80 T0 FD120-MSO include Rheem PROPH80 T0 RH120-M (3.46 UEF, at parity) alongside Richmond 10E80-HP120M (3.46 UEF, at parity).

How Complete Are the Certified Metrics for Friedrich PROH80 T0 FD120-MSO?

Standing at #549 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Friedrich PROH80 T0 FD120-MSO brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3845916
Model NumberPROH80 T0 FD120-MSODraw pattern: High-UsagePROH80 T0 FD120-MSO
Uniform Energy Factor (UEF)3.46-0.24 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)84 gal+12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,403 kWh/yr+331 kWh/yr vs. 1,072 kWh/yr medianEst. $255/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency393%-36.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57.8" H x 20" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 12 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States, Canada

What Is the Projected Utility Bill for PROH80 T0 FD120-MSO by State?

At 1,403 kWh/yr, Friedrich PROH80 T0 FD120-MSO averages about $255/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,403 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$255.00/yrHawaii$662.00/yrCalifornia$417.00/yrTexas$223.00/yrWashington$205.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $255/yr $2,548 $7,033
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $662/yr $6,619 $18,273
California 29.75 ¢/kWh ($0.2975) $417/yr $4,174 $11,522
Texas 15.91 ¢/kWh ($0.1591) $223/yr $2,232 $6,162
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $205/yr $2,053 $5,666
Estimated electricity spend (1,403 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Friedrich Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Friedrich in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to PROH80 T0 FD120-MSO?

Ordered by minimal capacity and UEF spread relative to Friedrich PROH80 T0 FD120-MSO, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem PROPH80 T0 RH120-M Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (at parity) 1,403
Richmond 10E80-HP120M Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (at parity) 1,403
Ruud PROUH80 T0 RU120-M Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (at parity) 1,403
LG APHWC801D Hybrid/Electric Heat Pump 72 gal 94 gal 3.9 (+0.44) 1,272
Rheem PROPH80 T0 RH120-MSO Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (at parity) 1,403

When Should Homeowners Skip Friedrich PROH80 T0 FD120-MSO (Hybrid/Electric Heat Pump)?

Check Friedrich PROH80 T0 FD120-MSO's mechanical constraints—including utility space, Electric capacity, and Pass: +0.96 / +38.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Friedrich PROH80 T0 FD120-MSO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Friedrich PROH80 T0 FD120-MSO directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Friedrich PROH80 T0 FD120-MSO Strong Fit — 3.46 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rheem PROPH80 T0 RH120-M footprint.

Practical Specs & Code Questions for Friedrich PROH80 T0 FD120-MSO

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Friedrich PROH80 T0 FD120-MSO stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.46 UEF, Friedrich PROH80 T0 FD120-MSO shows Pass: +0.96 / +38.4% relative to May 6, 2029 federal DOE limits while placing #549 of 706 among 706 Hybrid/Electric Heat Pump peers like Rheem PROPH80 T0 RH120-M.

Will Friedrich PROH80 T0 FD120-MSO fit through a standard utility door and 72-inch basement ceiling?

Measuring 57.8 in. tall by 20 in. diameter, Friedrich PROH80 T0 FD120-MSO notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Friedrich PROH80 T0 FD120-MSO during replacement?

Electrical specs for Friedrich PROH80 T0 FD120-MSO call for 120V at 12A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Friedrich PROH80 T0 FD120-MSO?

At 18.16 cents/kWh national residential pricing, Friedrich PROH80 T0 FD120-MSO's 1,403 kWh/yr draw equals roughly $255 annually or $2,550 across a 10-year horizon (ranging from $205/yr in Washington hydro tiers up to $662/yr in Hawaii).

When is Friedrich PROH80 T0 FD120-MSO a poor fit for a residential replacement?

Avoid placing Friedrich PROH80 T0 FD120-MSO directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Friedrich PROH80 T0 FD120-MSO deliver?

With 84 gal FHR (+12 gal vs. 72 gal median), Friedrich PROH80 T0 FD120-MSO fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Friedrich PROH80 T0 FD120-MSO?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Friedrich; verify exact manufacturing week for Friedrich PROH80 T0 FD120-MSO using the Serial Number Lookup tool.

Does Friedrich PROH80 T0 FD120-MSO qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Friedrich PROH80 T0 FD120-MSO. Closest peer in Hybrid/Electric Heat Pump is Rheem PROPH80 T0 RH120-M (3.46 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks