LG APHWC801D Water Heater Specifications (3.9 UEF)

The LG APHWC801D (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.9 UEF rating across its 72-gallon nominal tank, 94 gal First Hour Rating, ranking #144 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3417700). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.40 / +56.0%. Rated annual electricity draw of 1,272 kWh/yr equates to roughly $231/yr ($2,310 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Uniform Energy Factor
3.9 UEF
Cohort UEF Rank
#144 of 706 (top 22.9%)
First Hour Rating
94 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.40 / +56.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking LG APHWC801D at 3.9 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50LG APHWC801D: 3.90
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows LG APHWC801D relative to the cohort median.
Efficiency comparison & rule summary

LG APHWC801D (3.9 UEF) ranks #144 of 706 Hybrid/Electric Heat Pump models — 19-way tie; top 22.9%, more efficient than 77.1% of Hybrid/Electric Heat Pump models, +0.20 UEF above the 3.70 UEF median.

Federal 2029 margin for LG APHWC801D: +1.40 UEF (+56.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,272 kWh/yr for LG APHWC801D runs ~$231/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for LG APHWC801D: 10-year operating spend spans $1,861 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,001 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: LG APHWC801D (3.9 UEF) compares closely with Friedrich PROH80 T2 FD400-30 (4.07 UEF, delta +0.17) and Rheem CPROPH80 T2 RH375-SO (4.07 UEF, delta +0.17).

Which Specs Set LG APHWC801D Apart From Cohort Averages?

Ranked #144 of 706 (top 22.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, LG APHWC801D is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLG12 certified listingsENERGY STAR PD 3417700
Model NumberAPHWC801DDraw pattern: High-UsageAPHWC801D
Uniform Energy Factor (UEF)3.9+0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)94 gal+22 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,272 kWh/yr+200 kWh/yr vs. 1,072 kWh/yr medianEst. $231/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency410%-19.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.7" H x 19.7" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2024-03-05Certified 2024-03-05Markets: United States

How Do Regional kWh Prices Impact APHWC801D Over 10 Years?

Using EIA Table 5.6.A benchmarks, LG APHWC801D's 1,272 kWh/yr draw translates to roughly $231/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,272 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$231.00/yrHawaii$600.00/yrCalifornia$378.00/yrTexas$202.00/yrWashington$186.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $231/yr $2,310 $7,482
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $600/yr $6,001 $19,438
California 29.75 ¢/kWh ($0.2975) $378/yr $3,784 $12,257
Texas 15.91 ¢/kWh ($0.1591) $202/yr $2,024 $6,555
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $186/yr $1,861 $6,028
Estimated electricity spend (1,272 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should LG Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for LG; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD400-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (+0.17) 1,213
Rheem CPROPH80 T2 RH375-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (+0.17) 1,213
Richmond 10CE80-HP5S30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (+0.17) 1,213
Ruud CPROPH80 T2 CD375-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (+0.17) 1,213
Friedrich PROH80 T2 FD400-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (+0.17) 1,213

Which Home Setups Are NOT a Fit for LG APHWC801D?

Comparing LG APHWC801D against Friedrich PROH80 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • LG APHWC801D needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting LG APHWC801D directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing LG APHWC801D Strong Fit — 3.9 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-30 footprint.

Frequently Asked Technical Questions: LG APHWC801D

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does LG APHWC801D score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; LG APHWC801D logs 3.9 UEF (Pass: +1.40 / +56.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing LG APHWC801D?

With a 62.7 in. height and 19.7 in. diameter, LG APHWC801D fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits LG APHWC801D?

Powered via 240V at 24A max, LG APHWC801D requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for LG APHWC801D?

Annual electric spend for LG APHWC801D (1,272 kWh/yr) averages $231/yr nationwide (ranging from $186/yr in Washington hydro tiers up to $600/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing LG APHWC801D?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on LG APHWC801D.

Is LG APHWC801D sized adequately for a 2-to-4-person household?

ENERGY STAR certifies LG APHWC801D at 94 gal First Hour Rating (+22 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does LG have active CPSC SaferProducts notices affecting APHWC801D?

Zero CPSC recall alerts matched LG (2026-11-23 check). Keep your LG APHWC801D serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches LG APHWC801D (3.9 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for LG APHWC801D. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks