Skip to main content
ENERGY STAR water heater model · PD 3554249

Friedrich PROH80 T2 FD400-SO Water Heater Specifications (4.07 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Friedrich PROH80 T2 FD400-SO (Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating (rank #26 of 706, PD 3554249) and verifies as Pass: +1.57 / +62.8% for 2029 DOE floors. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH80 T2 RH375-SO (4.07 UEF).

Uniform Energy Factor
4.07 UEF
Cohort UEF Rank
#26 of 706 (top 8.5%)
First Hour Rating
87 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.57 / +62.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Friedrich PROH80 T2 FD400-SO at 4.07 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Friedrich PROH80 T2 FD400-SO: 4.07
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH80 T2 FD400-SO relative to the cohort median.
Efficiency comparison & rule summary

Friedrich PROH80 T2 FD400-SO records 4.07 UEF efficiency, putting it #26 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Friedrich PROH80 T2 FD400-SO exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.57 UEF (+62.8%). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Friedrich PROH80 T2 FD400-SO runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH80 T2 FD400-SO: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Friedrich PROH80 T2 FD400-SO (4.07 UEF) are Rheem CPROPH80 T2 RH375-SO (4.07 UEF, at parity) and Richmond 10CE80-HP5S30 (4.07 UEF, at parity).

Where Does Friedrich PROH80 T2 FD400-SO Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Friedrich PROH80 T2 FD400-SO holds #26 of 706 (top 8.5%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3554249
Model NumberPROH80 T2 FD400-SODraw pattern: High-UsagePROH80 T2 FD400-SO
Uniform Energy Factor (UEF)4.07+0.37 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)87 gal+15 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,213 kWh/yr+141 kWh/yr vs. 1,072 kWh/yr medianEst. $220/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency447%+18.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

How Much Electricity Does PROH80 T2 FD400-SO Use in Different States?

Estimated at $220/yr nationally (1,213 kWh/yr), 10-year utility spending for Friedrich PROH80 T2 FD400-SO shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,213 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$220.00/yrHawaii$572.00/yrCalifornia$361.00/yrTexas$193.00/yrWashington$177.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $220/yr $2,203 $7,542
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $572/yr $5,723 $19,594
California 29.75 ¢/kWh ($0.2975) $361/yr $3,609 $12,355
Texas 15.91 ¢/kWh ($0.1591) $193/yr $1,930 $6,607
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $177/yr $1,775 $6,076
Estimated electricity spend (1,213 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Friedrich Units?

No open CPSC recall alerts appeared for Friedrich as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PROH80 T2 FD400-SO?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Friedrich PROH80 T2 FD400-SO's gallon capacity and 4.07 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem CPROPH80 T2 RH375-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
Richmond 10CE80-HP5S30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
Ruud CPROPH80 T2 CD375-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
LG APHWC802D Hybrid/Electric Heat Pump 72 gal 91 gal 4.1 (+0.03) 1,210
Rheem CPROPH80 T2 RH400-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213

Which Home Setups Are NOT a Fit for Friedrich PROH80 T2 FD400-SO?

Comparing Friedrich PROH80 T2 FD400-SO against Rheem CPROPH80 T2 RH375-SO requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Friedrich PROH80 T2 FD400-SO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Friedrich PROH80 T2 FD400-SO directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Friedrich PROH80 T2 FD400-SO Strong Fit — 4.07 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rheem CPROPH80 T2 RH375-SO footprint.

Common Homeowner Questions for Friedrich PROH80 T2 FD400-SO

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Friedrich PROH80 T2 FD400-SO score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Friedrich PROH80 T2 FD400-SO logs 4.07 UEF (Pass: +1.57 / +62.8%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Friedrich PROH80 T2 FD400-SO?

With a 74.2 in. height and 24.3 in. diameter, Friedrich PROH80 T2 FD400-SO fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Friedrich PROH80 T2 FD400-SO?

Powered via 240V at 21A max, Friedrich PROH80 T2 FD400-SO requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Friedrich PROH80 T2 FD400-SO?

Annual electric spend for Friedrich PROH80 T2 FD400-SO (1,213 kWh/yr) averages $220/yr nationwide (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Friedrich PROH80 T2 FD400-SO?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Friedrich PROH80 T2 FD400-SO.

Is Friedrich PROH80 T2 FD400-SO sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Friedrich PROH80 T2 FD400-SO at 87 gal First Hour Rating (+15 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Friedrich have active CPSC SaferProducts notices affecting PROH80 T2 FD400-SO?

Zero CPSC recall alerts matched Friedrich (2026-11-23 check). Keep your Friedrich PROH80 T2 FD400-SO serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Friedrich PROH80 T2 FD400-SO (4.07 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Friedrich PROH80 T2 FD400-SO. Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH80 T2 RH375-SO (4.07 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks