ENERGY STAR water heater model · PD 3387967

Richmond 10CE80-HP5S30 Water Heater Specifications (4.07 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Richmond 10CE80-HP5S30 achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating and ranks #26 of 706 in its 706-model cohort (PD 3387967), recording Pass: +1.57 / +62.8% under 2029 DOE rules. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Uniform Energy Factor
4.07 UEF
Cohort UEF Rank
#26 of 706 (top 8.5%)
First Hour Rating
87 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.57 / +62.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10CE80-HP5S30 at 4.07 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Richmond 10CE80-HP5S30: 4.07
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10CE80-HP5S30 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Richmond 10CE80-HP5S30 logs 4.07 UEF and ranks #26 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Richmond 10CE80-HP5S30 holds a +1.57 UEF (+62.8%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Richmond 10CE80-HP5S30 runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10CE80-HP5S30: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Richmond 10CE80-HP5S30 (4.07 UEF)? Check Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Rheem CPROPH80 T2 RH375-SO (4.07 UEF, at parity).

How Complete Are the Certified Metrics for Richmond 10CE80-HP5S30?

Standing at #26 of 706 (top 8.5%) among 706 certified Hybrid/Electric Heat Pump heaters, Richmond 10CE80-HP5S30 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3387967
Model Number10CE80-HP5S30Draw pattern: High-Usage10CE80-HP5S30
Uniform Energy Factor (UEF)4.07+0.37 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)87 gal+15 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,213 kWh/yr+141 kWh/yr vs. 1,072 kWh/yr medianEst. $220/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency447%+18.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

What Is the Projected Utility Bill for 10CE80-HP5S30 by State?

At 1,213 kWh/yr, Richmond 10CE80-HP5S30 averages about $220/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,213 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$220.00/yrHawaii$572.00/yrCalifornia$361.00/yrTexas$193.00/yrWashington$177.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $220/yr $2,203 $7,542
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $572/yr $5,723 $19,594
California 29.75 ¢/kWh ($0.2975) $361/yr $3,609 $12,355
Texas 15.91 ¢/kWh ($0.1591) $193/yr $1,930 $6,607
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $177/yr $1,775 $6,076
Estimated electricity spend (1,213 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Richmond Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Richmond in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to 10CE80-HP5S30?

Ordered by minimal capacity and UEF spread relative to Richmond 10CE80-HP5S30, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD400-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
Rheem CPROPH80 T2 RH375-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
Ruud CPROPH80 T2 CD375-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
LG APHWC802D Hybrid/Electric Heat Pump 72 gal 91 gal 4.1 (+0.03) 1,210
Friedrich PROH80 T2 FD400-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213

What Installation Caveats Apply Before Buying Richmond 10CE80-HP5S30?

Even high-UEF units like Richmond 10CE80-HP5S30 (4.07 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Richmond 10CE80-HP5S30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10CE80-HP5S30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10CE80-HP5S30 Strong Fit — 4.07 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-30 footprint.

Practical Specs & Code Questions for Richmond 10CE80-HP5S30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Richmond 10CE80-HP5S30 eligible for continued manufacture past May 6, 2029?

At 4.07 UEF, Richmond 10CE80-HP5S30 achieves Pass: +1.57 / +62.8% for the 2029 DOE standard and stands #26 of 706 (top 8.5%) against Friedrich PROH80 T2 FD400-30 and Rheem CPROPH80 T2 RH375-SO.

How tall and wide is Richmond 10CE80-HP5S30, and what service clearance is needed?

Physical dimensions for Richmond 10CE80-HP5S30 are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

Will Richmond 10CE80-HP5S30 require upgrading household electrical panels or gas piping?

Richmond 10CE80-HP5S30 draws 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Richmond 10CE80-HP5S30 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $220/yr ($2,200 over 10 years) to power Richmond 10CE80-HP5S30 at 1,213 kWh/yr under the 18.16 cents/kWh US average (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii).

Which installation bottlenecks limit Richmond 10CE80-HP5S30?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Richmond 10CE80-HP5S30 drops into resistance mode more often.

How does Richmond 10CE80-HP5S30 handle simultaneous showers and laundry?

Delivering 87 gal in the first hour (+15 gal vs. 72 gal median), Richmond 10CE80-HP5S30 combines 72 gal tank storage with rapid burner/element recovery.

How long is the warranty on Richmond 10CE80-HP5S30 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Richmond as of 2026-11-23. Confirm install proof and serial manufacture year on Richmond 10CE80-HP5S30 before calling service.

How do 2026 post-OBBBA rebates affect buying Richmond 10CE80-HP5S30?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks