Engineered as a Electric Hybrid/Electric Heat Pump unit, GE Profile PH50S10BNY01 achieves a certified 4.5 UEF rating across its 50-gallon nominal tank, 75 gal First Hour Rating and ranks #1 of 706 in its 706-model cohort (PD 4016267), recording Pass: +2.20 / +95.7% under 2029 DOE rules. Rated annual electricity draw of 1,102 kWh/yr equates to roughly $200/yr ($2,001 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

Uniform Energy Factor
4.5 UEF
Cohort UEF Rank
#1 of 706 (top 0.4%)
First Hour Rating
75 gal
Storage Volume
50 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +2.20 / +95.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking GE Profile PH50S10BNY01 at 4.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30GE Profile PH50S10BNY01: 4.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PH50S10BNY01 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, GE Profile PH50S10BNY01 logs 4.5 UEF and ranks #1 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), GE Profile PH50S10BNY01 holds a +2.20 UEF (+95.7%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,102 kWh/yr for GE Profile PH50S10BNY01 runs ~$200/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PH50S10BNY01: 10-year operating spend spans $1,612 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,199 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping GE Profile PH50S10BNY01 (4.5 UEF)? Check A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF, delta -0.95) and American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF, delta -0.95).

Which Specs Set GE Profile PH50S10BNY01 Apart From Cohort Averages?

Ranked #1 of 706 (top 0.4%) inside the 706-model Hybrid/Electric Heat Pump cohort, GE Profile PH50S10BNY01 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGE Profile18 certified listingsENERGY STAR PD 4016267
Model NumberPH50S10BNY01Draw pattern: High-UsagePH50S10BNY01
Uniform Energy Factor (UEF)4.5+0.80 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)75 gal+3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,102 kWh/yr+30 kWh/yr vs. 1,072 kWh/yr medianEst. $200/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency491%+62.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)48.1" H x 18.5" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 23 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR1234YFLower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level41 dBAtop 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-05-28Certified 2025-05-28Markets: United States

How Do Regional kWh Prices Impact PH50S10BNY01 Over 10 Years?

Using EIA Table 5.6.A benchmarks, GE Profile PH50S10BNY01's 1,102 kWh/yr draw translates to roughly $200/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,102 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$200.00/yrHawaii$520.00/yrCalifornia$328.00/yrTexas$175.00/yrWashington$161.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $200/yr $2,001 $7,787
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $520/yr $5,199 $20,231
California 29.75 ¢/kWh ($0.2975) $328/yr $3,278 $12,757
Texas 15.91 ¢/kWh ($0.1591) $175/yr $1,753 $6,822
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $161/yr $1,612 $6,273
Estimated electricity spend (1,102 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should GE Profile Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for GE Profile; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.95) 915
American MHPCO-45 1**+MXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.95) 915
Giant GTHPCO-45 1**+GTXST-50LBTTP 1* Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.95) 915
GSW WATER HEATERS GHPCO-45 1**+GXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.95) 915
A. O. Smith HPACO-45C 1**+AXST-50LBCTTP 1* Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.95) 915

Which Home Setups Are NOT a Fit for GE Profile PH50S10BNY01?

Comparing GE Profile PH50S10BNY01 against A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • GE Profile PH50S10BNY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 41 dBA; avoid mounting GE Profile PH50S10BNY01 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing GE Profile PH50S10BNY01 Strong Fit — 4.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** footprint.

Frequently Asked Technical Questions: GE Profile PH50S10BNY01

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does GE Profile PH50S10BNY01 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; GE Profile PH50S10BNY01 logs 4.5 UEF (Pass: +2.20 / +95.7%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing GE Profile PH50S10BNY01?

With a 48.1 in. height and 18.5 in. diameter, GE Profile PH50S10BNY01 fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits GE Profile PH50S10BNY01?

Powered via 240V at 23A max, GE Profile PH50S10BNY01 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for GE Profile PH50S10BNY01?

Annual electric spend for GE Profile PH50S10BNY01 (1,102 kWh/yr) averages $200/yr nationwide (ranging from $161/yr in Washington hydro tiers up to $520/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing GE Profile PH50S10BNY01?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on GE Profile PH50S10BNY01.

Is GE Profile PH50S10BNY01 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies GE Profile PH50S10BNY01 at 75 gal First Hour Rating (+3 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does GE Profile have active CPSC SaferProducts notices affecting PH50S10BNY01?

Zero CPSC recall alerts matched GE Profile (2026-11-23 check). Keep your GE Profile PH50S10BNY01 serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches GE Profile PH50S10BNY01 (4.5 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for GE Profile PH50S10BNY01. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks