GE Profile PH50S10BPY01 Water Heater Specifications (4.3 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, GE Profile PH50S10BPY01 (Electric) achieves a certified 4.3 UEF rating across its 50-gallon nominal tank, 77 gal First Hour Rating (rank #5 of 706, PD 4020929) and verifies as Pass: +2.00 / +87.0% for 2029 DOE floors. Rated annual electricity draw of 1,154 kWh/yr equates to roughly $210/yr ($2,096 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

Uniform Energy Factor
4.3 UEF
Cohort UEF Rank
#5 of 706 (top 1%)
First Hour Rating
77 gal
Storage Volume
50 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +2.00 / +87.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking GE Profile PH50S10BPY01 at 4.3 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30GE Profile PH50S10BPY01: 4.30
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PH50S10BPY01 relative to the cohort median.
Efficiency comparison & rule summary

GE Profile PH50S10BPY01 records 4.3 UEF efficiency, putting it #5 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: GE Profile PH50S10BPY01 exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +2.00 UEF (+87.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,154 kWh/yr for GE Profile PH50S10BPY01 runs ~$210/yr vs. ~$980/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PH50S10BPY01: 10-year operating spend spans $1,688 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,445 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside GE Profile PH50S10BPY01 (4.3 UEF) are A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF, delta -0.75) and American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF, delta -0.75).

How Complete Are the Certified Metrics for GE Profile PH50S10BPY01?

Standing at #5 of 706 (top 1%) among 706 certified Hybrid/Electric Heat Pump heaters, GE Profile PH50S10BPY01 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGE Profile18 certified listingsENERGY STAR PD 4020929
Model NumberPH50S10BPY01Draw pattern: High-UsagePH50S10BPY01
Uniform Energy Factor (UEF)4.3+0.60 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)77 gal+5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,154 kWh/yr+82 kWh/yr vs. 1,072 kWh/yr medianEst. $210/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency472%+43.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)48.1" H x 18.5" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 23 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR1234YFLower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level41 dBAtop 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-05-28Certified 2025-05-28Markets: United States

What Is the Projected Utility Bill for PH50S10BPY01 by State?

At 1,154 kWh/yr, GE Profile PH50S10BPY01 averages about $210/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,154 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$210.00/yrHawaii$544.00/yrCalifornia$343.00/yrTexas$184.00/yrWashington$169.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $210/yr $2,096 $7,700
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $544/yr $5,445 $20,004
California 29.75 ¢/kWh ($0.2975) $343/yr $3,433 $12,614
Texas 15.91 ¢/kWh ($0.1591) $184/yr $1,836 $6,746
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $169/yr $1,688 $6,203
Estimated electricity spend (1,154 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are GE Profile Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched GE Profile in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to PH50S10BPY01?

Ordered by minimal capacity and UEF spread relative to GE Profile PH50S10BPY01, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.75) 915
American MHPCO-45 1**+MXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.75) 915
Giant GTHPCO-45 1**+GTXST-50LBTTP 1* Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.75) 915
GSW WATER HEATERS GHPCO-45 1**+GXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.75) 915
A. O. Smith HPACO-45C 1**+AXST-50LBCTTP 1* Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (-0.75) 915

What Installation Caveats Apply Before Buying GE Profile PH50S10BPY01?

Even high-UEF units like GE Profile PH50S10BPY01 (4.3 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • GE Profile PH50S10BPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 41 dBA; avoid mounting GE Profile PH50S10BPY01 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing GE Profile PH50S10BPY01 Strong Fit — 4.3 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** footprint.

Practical Specs & Code Questions for GE Profile PH50S10BPY01

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is GE Profile PH50S10BPY01 eligible for continued manufacture past May 6, 2029?

At 4.3 UEF, GE Profile PH50S10BPY01 achieves Pass: +2.00 / +87.0% for the 2029 DOE standard and stands #5 of 706 (top 1%) against A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** and American MHPCO-45 1**+MXST-50LBTTP 1**.

How tall and wide is GE Profile PH50S10BPY01, and what service clearance is needed?

Physical dimensions for GE Profile PH50S10BPY01 are 48.1 in. height and 18.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" d)); verify stair turns and drain pan width before delivery.

Will GE Profile PH50S10BPY01 require upgrading household electrical panels or gas piping?

GE Profile PH50S10BPY01 draws 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is GE Profile PH50S10BPY01 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $210/yr ($2,100 over 10 years) to power GE Profile PH50S10BPY01 at 1,154 kWh/yr under the 18.16 cents/kWh US average (ranging from $169/yr in Washington hydro tiers up to $544/yr in Hawaii).

Which installation bottlenecks limit GE Profile PH50S10BPY01?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, GE Profile PH50S10BPY01 drops into resistance mode more often.

How does GE Profile PH50S10BPY01 handle simultaneous showers and laundry?

Delivering 77 gal in the first hour (+5 gal vs. 72 gal median), GE Profile PH50S10BPY01 combines 50 gal tank storage with rapid burner/element recovery.

How long is the warranty on GE Profile PH50S10BPY01 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for GE Profile as of 2026-11-23. Confirm install proof and serial manufacture year on GE Profile PH50S10BPY01 before calling service.

How do 2026 post-OBBBA rebates affect buying GE Profile PH50S10BPY01?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks