Skip to main content
ENERGY STAR water heater model · PD 4529477

Giant GTHPCO-45 1**+GTXST-50STTP 1** Water Heater Specifications (3.52 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Giant GTHPCO-45 1**+GTXST-50STTP 1** achieves a certified 3.52 UEF rating across its 46-gallon nominal tank, 70 gal First Hour Rating and ranks #441 of 706 in its 706-model cohort (PD 4529477), recording Pass: +1.22 / +53.0% under 2029 DOE rules. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
70 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Giant GTHPCO-45 1**+GTXST-50STTP 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Giant GTHPCO-45 1**+GTXST-50STTP 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Giant GTHPCO-45 1**+GTXST-50STTP 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Giant GTHPCO-45 1**+GTXST-50STTP 1** logs 3.52 UEF and ranks #441 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Giant GTHPCO-45 1**+GTXST-50STTP 1** holds a +1.22 UEF (+53.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for Giant GTHPCO-45 1**+GTXST-50STTP 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Giant GTHPCO-45 1**+GTXST-50STTP 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Giant GTHPCO-45 1**+GTXST-50STTP 1** (3.52 UEF)? Check A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50S 1** (3.52 UEF, at parity).

How Do Giant GTHPCO-45 1**+GTXST-50STTP 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

Giant GTHPCO-45 1**+GTXST-50STTP 1** places #441 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGiant12 certified listingsENERGY STAR PD 4529477
Model NumberGTHPCO-45 1**+GTXST-50STTP 1**Draw pattern: Medium-UsageGTHPCO-45 1**+GTXST-50STTP 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)70 gal-2 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency429%At 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)46.6" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-03-19Certified 2026-03-19Markets: United States, Canada

What Does GTHPCO-45 1**+GTXST-50STTP 1** Cost to Operate Across State Electricity Rates?

At 923 kWh/yr, Giant GTHPCO-45 1**+GTXST-50STTP 1** runs roughly $168/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Giant Water Heaters?

Zero active CPSC recalls matched Giant in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match GTHPCO-45 1**+GTXST-50STTP 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Giant GTHPCO-45 1**+GTXST-50STTP 1** by storage capacity and 3.52 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
American MHPCO-45 1**+MXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
GSW WATER HEATERS GHPCO-45 1**+GXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
John Wood JWHPCO-45 1**+JWXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
A. O. Smith HPACO-45 1**+AXST-50STTP 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923

Which Home Setups Are NOT a Fit for Giant GTHPCO-45 1**+GTXST-50STTP 1**?

Comparing Giant GTHPCO-45 1**+GTXST-50STTP 1** against A. O. Smith HPACO-45 1**+AXST-50S 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Giant GTHPCO-45 1**+GTXST-50STTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Giant GTHPCO-45 1**+GTXST-50STTP 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Giant GTHPCO-45 1**+GTXST-50STTP 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50S 1** footprint.

What Are the Key Questions About Giant GTHPCO-45 1**+GTXST-50STTP 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Giant GTHPCO-45 1**+GTXST-50STTP 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Giant GTHPCO-45 1**+GTXST-50STTP 1** logs 3.52 UEF (Pass: +1.22 / +53.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Giant GTHPCO-45 1**+GTXST-50STTP 1**?

With a 46.6 in. height and 18 in. diameter, Giant GTHPCO-45 1**+GTXST-50STTP 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Giant GTHPCO-45 1**+GTXST-50STTP 1**?

Powered via 240V at 20.2A max, Giant GTHPCO-45 1**+GTXST-50STTP 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Giant GTHPCO-45 1**+GTXST-50STTP 1**?

Annual electric spend for Giant GTHPCO-45 1**+GTXST-50STTP 1** (923 kWh/yr) averages $168/yr nationwide (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Giant GTHPCO-45 1**+GTXST-50STTP 1**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Giant GTHPCO-45 1**+GTXST-50STTP 1**.

Is Giant GTHPCO-45 1**+GTXST-50STTP 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Giant GTHPCO-45 1**+GTXST-50STTP 1** at 70 gal First Hour Rating (-2 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Giant have active CPSC SaferProducts notices affecting GTHPCO-45 1**+GTXST-50STTP 1**?

Zero CPSC recall alerts matched Giant (2026-11-23 check). Keep your Giant GTHPCO-45 1**+GTXST-50STTP 1** serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Giant GTHPCO-45 1**+GTXST-50STTP 1** (3.52 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Giant GTHPCO-45 1**+GTXST-50STTP 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks