Skip to main content
ENERGY STAR water heater model · PD 4529406

Giant GTHPCO-45 1**+GTXST-66TTP 1** Water Heater Specifications (3.7 UEF)

Certified at 3.7 UEF across its 60-gallon nominal tank, 82 gal First Hour Rating, Giant GTHPCO-45 1**+GTXST-66TTP 1** (Hybrid/Electric Heat Pump, Electric) places #347 of 706 out of 706 ENERGY STAR models (PD 4529406). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.20 / +48.0%. Rated annual electricity draw of 1,341 kWh/yr equates to roughly $244/yr ($2,435 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
82 gal
Storage Volume
60 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Giant GTHPCO-45 1**+GTXST-66TTP 1** at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Giant GTHPCO-45 1**+GTXST-66TTP 1**: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Giant GTHPCO-45 1**+GTXST-66TTP 1** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.7 UEF, Giant GTHPCO-45 1**+GTXST-66TTP 1** places #347 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (At 3.70 UEF median).

Giant GTHPCO-45 1**+GTXST-66TTP 1** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.20 UEF (+48.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,341 kWh/yr for Giant GTHPCO-45 1**+GTXST-66TTP 1** runs ~$244/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for Giant GTHPCO-45 1**+GTXST-66TTP 1**: 10-year operating spend spans $1,962 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,327 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Giant GTHPCO-45 1**+GTXST-66TTP 1** include A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF, at parity) alongside American MHPCO-45 1**+MXST-66 1** (3.7 UEF, at parity).

How Complete Are the Certified Metrics for Giant GTHPCO-45 1**+GTXST-66TTP 1**?

Standing at #347 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Giant GTHPCO-45 1**+GTXST-66TTP 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGiant12 certified listingsENERGY STAR PD 4529406
Model NumberGTHPCO-45 1**+GTXST-66TTP 1**Draw pattern: High-UsageGTHPCO-45 1**+GTXST-66TTP 1**
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,341 kWh/yr+269 kWh/yr vs. 1,072 kWh/yr medianEst. $244/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)59" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-03-19Certified 2026-03-19Markets: United States, Canada

What Is the Projected Utility Bill for GTHPCO-45 1**+GTXST-66TTP 1** by State?

At 1,341 kWh/yr, Giant GTHPCO-45 1**+GTXST-66TTP 1** averages about $244/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,341 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$244.00/yrHawaii$633.00/yrCalifornia$399.00/yrTexas$213.00/yrWashington$196.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $244/yr $2,435 $7,358
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $633/yr $6,327 $19,117
California 29.75 ¢/kWh ($0.2975) $399/yr $3,989 $12,055
Texas 15.91 ¢/kWh ($0.1591) $213/yr $2,134 $6,447
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $196/yr $1,962 $5,928
Estimated electricity spend (1,341 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Giant Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Giant in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to GTHPCO-45 1**+GTXST-66TTP 1**?

Ordered by minimal capacity and UEF spread relative to Giant GTHPCO-45 1**+GTXST-66TTP 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
American MHPCO-45 1**+MXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
GSW WATER HEATERS GHPCO-45 1**+GXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
John Wood JWHPCO-45 1**+JWXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
A. O. Smith HPACO-45 1**+AXST-66TTP 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341

What Installation Caveats Apply Before Buying Giant GTHPCO-45 1**+GTXST-66TTP 1**?

Even high-UEF units like Giant GTHPCO-45 1**+GTXST-66TTP 1** (3.7 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Giant GTHPCO-45 1**+GTXST-66TTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Giant GTHPCO-45 1**+GTXST-66TTP 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Giant GTHPCO-45 1**+GTXST-66TTP 1** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-66 1** footprint.

Practical Specs & Code Questions for Giant GTHPCO-45 1**+GTXST-66TTP 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Giant GTHPCO-45 1**+GTXST-66TTP 1** eligible for continued manufacture past May 6, 2029?

At 3.7 UEF, Giant GTHPCO-45 1**+GTXST-66TTP 1** achieves Pass: +1.20 / +48.0% for the 2029 DOE standard and stands #347 of 706 against A. O. Smith HPACO-45 1**+AXST-66 1** and American MHPCO-45 1**+MXST-66 1**.

How tall and wide is Giant GTHPCO-45 1**+GTXST-66TTP 1**, and what service clearance is needed?

Physical dimensions for Giant GTHPCO-45 1**+GTXST-66TTP 1** are 59 in. height and 18 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d)); verify stair turns and drain pan width before delivery.

Will Giant GTHPCO-45 1**+GTXST-66TTP 1** require upgrading household electrical panels or gas piping?

Giant GTHPCO-45 1**+GTXST-66TTP 1** draws 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Giant GTHPCO-45 1**+GTXST-66TTP 1** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $244/yr ($2,440 over 10 years) to power Giant GTHPCO-45 1**+GTXST-66TTP 1** at 1,341 kWh/yr under the 18.16 cents/kWh US average (ranging from $196/yr in Washington hydro tiers up to $633/yr in Hawaii).

Which installation bottlenecks limit Giant GTHPCO-45 1**+GTXST-66TTP 1**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Giant GTHPCO-45 1**+GTXST-66TTP 1** drops into resistance mode more often.

How does Giant GTHPCO-45 1**+GTXST-66TTP 1** handle simultaneous showers and laundry?

Delivering 82 gal in the first hour (+10 gal vs. 72 gal median), Giant GTHPCO-45 1**+GTXST-66TTP 1** combines 60 gal tank storage with rapid burner/element recovery.

How long is the warranty on Giant GTHPCO-45 1**+GTXST-66TTP 1** and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Giant as of 2026-11-23. Confirm install proof and serial manufacture year on Giant GTHPCO-45 1**+GTXST-66TTP 1** before calling service.

How do 2026 post-OBBBA rebates affect buying Giant GTHPCO-45 1**+GTXST-66TTP 1**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks