Gridless AYHW80G Water Heater Specifications (4 UEF)
With PD 3999583 certification, Gridless AYHW80G (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating, standing #106 of 706 across 706 peers with Pass: +1.50 / +60.0% for May 6, 2029. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).
- Uniform Energy Factor
- 4.0 UEF
- Cohort UEF Rank
- #106 of 706 (top 19.8%)
- First Hour Rating
- 91 gal
- Storage Volume
- 74 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.50 / +60.0%

ENERGY STAR certification places Gridless AYHW80G at 4.0 UEF (#106 of 706; +0.30 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Gridless AYHW80G stands +1.50 UEF (+60.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Gridless AYHW80G runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Gridless AYHW80G: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity) bracket Gridless AYHW80G.
Which Specs Set Gridless AYHW80G Apart From Cohort Averages?
Ranked #106 of 706 (top 19.8%) inside the 706-model Hybrid/Electric Heat Pump cohort, Gridless AYHW80G is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Gridless | 2 certified listings | ENERGY STAR PD 3999583 |
| Model Number | AYHW80G | Draw pattern: High-Usage | AYHW80G |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 91 gal | +19 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,240 kWh/yr | +168 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 41.7" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2025-03-07 | Certified 2025-03-07 | Markets: United States, Canada |
How Do Regional kWh Prices Impact AYHW80G Over 10 Years?
Using EIA Table 5.6.A benchmarks, Gridless AYHW80G's 1,240 kWh/yr draw translates to roughly $225/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,252 | $7,538 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $585/yr | $5,850 | $19,584 |
| California | 29.75 ¢/kWh ($0.2975) | $369/yr | $3,689 | $12,349 |
| Texas | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,973 | $6,604 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,814 | $6,073 |
What Should Gridless Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Gridless; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| 1HVAC ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| ACIQ ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| Bosch TR7000T - 80CA | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| Custom Comfort CCOHPWH80A | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| Bosch TR7000T - 80US | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
When Should Homeowners Skip Gridless AYHW80G (Hybrid/Electric Heat Pump)?
Check Gridless AYHW80G's mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +60.0% status—against typical residential installations.
Key Limitations & Exclusions
- Gridless AYHW80G needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Gridless AYHW80G directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Gridless AYHW80G
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Gridless AYHW80G stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 4.0 UEF, Gridless AYHW80G shows Pass: +1.50 / +60.0% relative to May 6, 2029 federal DOE limits while placing #106 of 706 (top 19.8%) among 706 Hybrid/Electric Heat Pump peers like 1HVAC ACIQ-80G-HP-WH.
Will Gridless AYHW80G fit through a standard utility door and 72-inch basement ceiling?
Measuring 41.7 in. tall by 21.8 in. diameter, Gridless AYHW80G notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Gridless AYHW80G during replacement?
Electrical specs for Gridless AYHW80G call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Gridless AYHW80G?
At 18.16 cents/kWh national residential pricing, Gridless AYHW80G's 1,240 kWh/yr draw equals roughly $225 annually or $2,250 across a 10-year horizon (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).
When is Gridless AYHW80G a poor fit for a residential replacement?
Avoid placing Gridless AYHW80G directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Gridless AYHW80G deliver?
With 91 gal FHR (+19 gal vs. 72 gal median), Gridless AYHW80G fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Gridless AYHW80G?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Gridless; verify exact manufacturing week for Gridless AYHW80G using the Serial Number Lookup tool.
Does Gridless AYHW80G qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Gridless AYHW80G. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)