Skip to main content
ENERGY STAR water heater model · PD 2853717

Heliodyne HPAK 1 406 GT 65 ACD Z Water Heater Specifications (99 SUEF)

Engineered as a Natural Gas Solar with Gas Backup unit, Heliodyne HPAK 1 406 GT 65 ACD Z achieves a certified 99.0 SUEF rating across its 65-gallon nominal tank and ranks #1 of 25 in its 25-model cohort (PD 2853717), recording Exempt — Solar SUEF under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is SAMMLER A208 (99.0 SUEF).

Solar UEF (SUEF)
99.0 SUEF
Cohort SUEF Rank
#1 of 25
First Hour Rating
On-Demand
Storage Volume
65 gal
Fuel / Type
Natural Gas / Solar with Gas Backup
DOE 2029 Rule Status
Exempt — Solar SUEF
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units)Distribution of certified SUEF ratings across 25 units in Solar with Gas Backup, marking Heliodyne HPAK 1 406 GT 65 ACD Z at 99.0 SUEF.9112121.90 SUEF99.00 SUEFMedian 84.50Heliodyne HPAK 1 406 GT 65 ACD Z: 99.00
Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units). Highlighted pin shows Heliodyne HPAK 1 406 GT 65 ACD Z relative to the cohort median.
Efficiency comparison & rule summary

Within the 25-unit Solar with Gas Backup cohort, Heliodyne HPAK 1 406 GT 65 ACD Z logs 99.0 SUEF and ranks #1 of 25.

Solar collector & storage profile, OG-300 #30004381 for Heliodyne HPAK 1 406 GT 65 ACD Z: Indirect Forced Circulation architecture; 26.9 sq ft Flat Plate collector; 65 gal storage tank; freeze limit -58 deg F.

Cross-shopping Heliodyne HPAK 1 406 GT 65 ACD Z (99.0 SUEF)? Check SAMMLER A208 (99.0 SUEF, at parity) and GREENoneTEC Double GT (6.7 SUEF, delta -92.30).

How Do Heliodyne HPAK 1 406 GT 65 ACD Z Specs Compare to Solar with Gas Backup Medians?

Heliodyne HPAK 1 406 GT 65 ACD Z places #1 of 25 across 25 certified Solar with Gas Backup configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 25 ENERGY STAR Solar with Gas Backup peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandHeliodyne6 certified listingsENERGY STAR PD 2853717
Model NumberHPAK 1 406 GT 65 ACD ZDraw pattern: Low-UsageHPAK 1 406 GT 65 ACD Z
Solar Uniform Energy Factor (SUEF)99.0+14.50 SUEF vs. 84.50 SUEF median10 CFR 430 Test Method
Solar System & CollectorIndirect Forced Circulation (Flat Plate)26.9 sq ft apertureOG-300 #30004381
Collector Freeze Tolerance-58 °FSRCC freeze protection ratingENERGY STAR Solar Dataset
Certification Date2023-12-13Certified 2023-12-13Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Heliodyne Water Heaters?

Zero active CPSC recalls matched Heliodyne in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match HPAK 1 406 GT 65 ACD Z Most Closely?

These 5 competing Solar with Gas Backup units sit nearest to Heliodyne HPAK 1 406 GT 65 ACD Z by storage capacity and 99.0 SUEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRSUEF (Δ)kWh/yr
SAMMLER A208 Solar with Gas Backup 53 gal — 99.0 (at parity) —
GREENoneTEC Double GT Solar with Gas Backup 51 gal — 6.7 (-92.30) —
AET B-DBS-G2-80-64 Solar with Gas Backup 80 gal — 1.9 (-97.10) —
Rheem RS80-40BP-TG Solar with Gas Backup 80 gal — 8.0 (-91.00) —
SAMMLER A228 Solar with Gas Backup 53 gal — 99.0 (at parity) —

What Are the Limitations of Heliodyne HPAK 1 406 GT 65 ACD Z and Who Should Not Install It?

Before ordering Heliodyne HPAK 1 406 GT 65 ACD Z (Solar with Gas Backup, 99.0 SUEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Heliodyne HPAK 1 406 GT 65 ACD Z logs 99.0 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Heliodyne HPAK 1 406 GT 65 ACD Z's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 65 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Heliodyne HPAK 1 406 GT 65 ACD Z Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like SAMMLER A208.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

What Are the Key Questions About Heliodyne HPAK 1 406 GT 65 ACD Z?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Heliodyne HPAK 1 406 GT 65 ACD Z pass the May 6, 2029 federal DOE efficiency rule?

Heliodyne HPAK 1 406 GT 65 ACD Z is a solar thermal collector system rated at 99.0 SUEF. Solar thermal assemblies remain outside residential electric storage and gas tankless UEF floors under 10 CFR 430.32.

What doorway width and ceiling height does Heliodyne HPAK 1 406 GT 65 ACD Z need?

Heliodyne HPAK 1 406 GT 65 ACD Z mounts as a solar with gas backup without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

What gas pipe size or electrical breaker does Heliodyne HPAK 1 406 GT 65 ACD Z require?

Heliodyne HPAK 1 406 GT 65 ACD Z runs on Natural Gas (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does Heliodyne HPAK 1 406 GT 65 ACD Z cost per year to run?

ENERGY STAR rates Heliodyne HPAK 1 406 GT 65 ACD Z as a Natural Gas heater (99.0 SUEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Solar with Gas Backup draw.

Who should NOT install Heliodyne HPAK 1 406 GT 65 ACD Z, and what are its limits?

Heliodyne HPAK 1 406 GT 65 ACD Z (99.0 SUEF) is not suited for multi-bath marathon draws exceeding its 65 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

How many bathrooms or people can Heliodyne HPAK 1 406 GT 65 ACD Z serve at peak demand?

Heliodyne HPAK 1 406 GT 65 ACD Z provides continuous Solar with Gas Backup delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.

Are there CPSC safety recalls or serial checks for Heliodyne HPAK 1 406 GT 65 ACD Z?

No active CPSC recalls matched Heliodyne as of 2026-11-23. Always decode the serial tag on Heliodyne HPAK 1 406 GT 65 ACD Z because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Heliodyne HPAK 1 406 GT 65 ACD Z, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Solar with Gas Backup is SAMMLER A208 (99.0 SUEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks