Skip to main content
ENERGY STAR water heater model · PD 2408829

HTP PH100-119**** Water Heater Specifications (0.9 UEF)

In the 71-unit Gas-fired Storage Residential-duty Commercial class, HTP PH100-119**** (Natural Gas, Propane) achieves a certified 0.9 UEF rating across its 112-gallon nominal tank, 178 gal First Hour Rating (rank #2 of 71, PD 2408829) and verifies as Pass: +0.32 / +55.2% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and needs >72 in. overhead clearance; tight at 28 in. door (27" d). Closest certified alternative is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#2 of 71 (top 9.9%)
First Hour Rating
178 gal
Storage Volume
112 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking HTP PH100-119**** at 0.9 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58HTP PH100-119****: 0.90
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows HTP PH100-119**** relative to the cohort median.
Efficiency comparison & rule summary

HTP PH100-119**** records 0.9 UEF efficiency, putting it #2 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers.

Htp ph100-119**** stores 112 gal nominal; 178 gal first hour rating (+42 gal vs. 136 gal median); needs >72 in. overhead clearance; tight at 28 in. door (27" d).

Competing options beside HTP PH100-119**** (0.9 UEF) are Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF, delta -0.02) and Rheem PROPG75-100P RH HE EC3 (0.88 UEF, delta -0.02).

Which Specs Set HTP PH100-119**** Apart From Cohort Averages?

Ranked #2 of 71 (top 9.9%) inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, HTP PH100-119**** is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandHTP6 certified listingsENERGY STAR PD 2408829
Model NumberPH100-119****Draw pattern: High-UsagePH100-119****
Uniform Energy Factor (UEF)0.9+0.02 UEF vs. 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)178 gal+42 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency96%+1.0 pts vs. 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74" H x 27" DNeeds >72 in. overhead clearance; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements1 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-12Certified 2024-11-12Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should HTP Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for HTP; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?

Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 75-100P FD HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.02) —
Rheem PROPG75-100P RH HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.02) —
Richmond 12GUH75-100FN Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.02) —
Ruud PROUG75-100P RU HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.02) —
Friedrich 12PROG 75-100U FD HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.02) —

Who Is HTP PH100-119**** Best For — and When Should You Pick Friedrich 12PROG 75-100P FD HE EC3?

Evaluate whether HTP PH100-119****'s Gas-fired Storage Residential-duty Commercial architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • HTP PH100-119**** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect HTP PH100-119****'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 178 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for HTP PH100-119**** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 75-100P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Frequently Asked Technical Questions: HTP PH100-119****

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does HTP PH100-119**** (0.9 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, HTP PH100-119**** records 0.9 UEF (Pass: +0.32 / +55.2%), placing #2 of 71 (top 9.9%) out of 71 certified Gas-fired Storage Residential-duty Commercial configurations.

Does HTP PH100-119**** fit inside a tight hallway closet or low-headroom utility room?

HTP PH100-119**** requires room for its 74 in. vertical shell and 27 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (27" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern HTP PH100-119****?

Installing HTP PH100-119**** on Natural Gas, Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for HTP PH100-119****?

Rated 0.9 UEF on Natural Gas, Propane, HTP PH100-119**** carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas-fired Storage Residential-duty Commercial models.

What are the main drawbacks of HTP PH100-119**** (0.9 UEF)?

Buyers expecting endless simultaneous shower flow beyond 178 gal should compare condensing tankless units or larger-capacity tanks.

What hot-water delivery rating governs HTP PH100-119****?

Rated for 178 gal FHR (+42 gal vs. 136 gal median), HTP PH100-119**** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen HTP PH100-119**** for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for HTP; use our browser-only serial decoder to inspect HTP PH100-119****'s age and warranty window.

What alternative models sit closest to HTP PH100-119**** in the Gas-fired Storage Residential-duty Commercial class?

Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks