Richmond 12GUH75-100FN Water Heater Specifications (0.88 UEF)
The Richmond 12GUH75-100FN (Gas-fired Storage Residential-duty Commercial, Natural Gas) achieves a certified 0.88 UEF rating across its 75-gallon nominal tank, 199 gal First Hour Rating, ranking #34 of 71 among 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models (PD 3387600). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.30 / +51.7%. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (26.3" d). Closest certified alternative is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).
- Uniform Energy Factor
- 0.88 UEF
- Cohort UEF Rank
- #34 of 71
- First Hour Rating
- 199 gal
- Storage Volume
- 75 gal
- Fuel / Type
- Natural Gas / Gas-fired Storage Residential-duty Commercial
- DOE 2029 Rule Status
- Pass: +0.30 / +51.7%

Richmond 12GUH75-100FN (0.88 UEF) ranks #34 of 71 Gas-fired Storage Residential-duty Commercial models — 27-way tie; more efficient than 15.5% of Gas-fired Storage Residential-duty Commercial models, at the 0.88 UEF median.
Richmond 12guh75-100fn stores 75 gal nominal; 199 gal first hour rating (+63 gal vs. 136 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (26.3" d).
Peer comparison: Richmond 12GUH75-100FN (0.88 UEF) compares closely with Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF, at parity) and Rheem PROPG75-100P RH HE EC3 (0.88 UEF, at parity).
Where Does Richmond 12GUH75-100FN Rank Against Peer Gas-fired Storage Residential-duty Commercial Units?
Audited against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial listings, Richmond 12GUH75-100FN holds #34 of 71; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3387600 |
| Model Number | 12GUH75-100FN | Draw pattern: High-Usage | 12GUH75-100FN |
| Uniform Energy Factor (UEF) | 0.88 | At 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 199 gal | +63 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 95% | At 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.5" H x 26.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (26.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-05-08 | Certified 2025-05-08 | Markets: United States |
Does CPSC Flag Any Safety Notices on Richmond Units?
No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Gas-fired Storage Residential-duty Commercial Models Compare Closest to 12GUH75-100FN?
Compare five nearby ENERGY STAR Gas-fired Storage Residential-duty Commercial options matched closely to Richmond 12GUH75-100FN's gallon capacity and 0.88 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich 12PROG 75-100P FD HE EC3 | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (at parity) | — |
| Rheem PROPG75-100P RH HE EC3 | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (at parity) | — |
| Ruud PROUG75-100P RU HE EC3 | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (at parity) | — |
| HTP PH100-80**** | Gas-fired Storage Residential-duty Commercial | 75 gal | 132 gal | 0.93 (+0.05) | — |
| Friedrich 12PROG 75-100U FD HE EC3 | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (at parity) | — |
Who Is Richmond 12GUH75-100FN Best For — and When Should You Pick Friedrich 12PROG 75-100P FD HE EC3?
Evaluate whether Richmond 12GUH75-100FN's Gas-fired Storage Residential-duty Commercial architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Richmond 12GUH75-100FN logs 0.88 UEF (Pass: +0.30 / +51.7%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Richmond 12GUH75-100FN's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 199 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Common Homeowner Questions for Richmond 12GUH75-100FN
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Richmond 12GUH75-100FN (0.88 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Richmond 12GUH75-100FN records 0.88 UEF (Pass: +0.30 / +51.7%), placing #34 of 71 out of 71 certified Gas-fired Storage Residential-duty Commercial configurations.
Does Richmond 12GUH75-100FN fit inside a tight hallway closet or low-headroom utility room?
Richmond 12GUH75-100FN requires room for its 64.5 in. vertical shell and 26.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (26.3" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Richmond 12GUH75-100FN?
Installing Richmond 12GUH75-100FN on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.
What annual utility bill should homeowners budget for Richmond 12GUH75-100FN?
Rated 0.88 UEF on Natural Gas, Richmond 12GUH75-100FN carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas-fired Storage Residential-duty Commercial models.
What are the main drawbacks of Richmond 12GUH75-100FN (0.88 UEF)?
Buyers expecting endless simultaneous shower flow beyond 199 gal should compare condensing tankless units or larger-capacity tanks.
What hot-water delivery rating governs Richmond 12GUH75-100FN?
Rated for 199 gal FHR (+63 gal vs. 136 gal median), Richmond 12GUH75-100FN prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Richmond 12GUH75-100FN for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Richmond; use our browser-only serial decoder to inspect Richmond 12GUH75-100FN's age and warranty window.
What alternative models sit closest to Richmond 12GUH75-100FN in the Gas-fired Storage Residential-duty Commercial class?
Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)