Skip to main content
ENERGY STAR water heater model · PD 3387600

Richmond 12GUH75-100FN Water Heater Specifications (0.88 UEF)

The Richmond 12GUH75-100FN (Gas-fired Storage Residential-duty Commercial, Natural Gas) achieves a certified 0.88 UEF rating across its 75-gallon nominal tank, 199 gal First Hour Rating, ranking #34 of 71 among 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models (PD 3387600). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.30 / +51.7%. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (26.3" d). Closest certified alternative is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).

Uniform Energy Factor
0.88 UEF
Cohort UEF Rank
#34 of 71
First Hour Rating
199 gal
Storage Volume
75 gal
Fuel / Type
Natural Gas / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.30 / +51.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking Richmond 12GUH75-100FN at 0.88 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58Richmond 12GUH75-100FN: 0.88
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Richmond 12GUH75-100FN relative to the cohort median.
Efficiency comparison & rule summary

Richmond 12GUH75-100FN (0.88 UEF) ranks #34 of 71 Gas-fired Storage Residential-duty Commercial models — 27-way tie; more efficient than 15.5% of Gas-fired Storage Residential-duty Commercial models, at the 0.88 UEF median.

Richmond 12guh75-100fn stores 75 gal nominal; 199 gal first hour rating (+63 gal vs. 136 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (26.3" d).

Peer comparison: Richmond 12GUH75-100FN (0.88 UEF) compares closely with Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF, at parity) and Rheem PROPG75-100P RH HE EC3 (0.88 UEF, at parity).

Where Does Richmond 12GUH75-100FN Rank Against Peer Gas-fired Storage Residential-duty Commercial Units?

Audited against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial listings, Richmond 12GUH75-100FN holds #34 of 71; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3387600
Model Number12GUH75-100FNDraw pattern: High-Usage12GUH75-100FN
Uniform Energy Factor (UEF)0.88At 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)199 gal+63 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency95%At 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.5" H x 26.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (26.3" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-05-08Certified 2025-05-08Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Richmond Units?

No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Gas-fired Storage Residential-duty Commercial Models Compare Closest to 12GUH75-100FN?

Compare five nearby ENERGY STAR Gas-fired Storage Residential-duty Commercial options matched closely to Richmond 12GUH75-100FN's gallon capacity and 0.88 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 75-100P FD HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (at parity) —
Rheem PROPG75-100P RH HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (at parity) —
Ruud PROUG75-100P RU HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (at parity) —
HTP PH100-80**** Gas-fired Storage Residential-duty Commercial 75 gal 132 gal 0.93 (+0.05) —
Friedrich 12PROG 75-100U FD HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (at parity) —

Who Is Richmond 12GUH75-100FN Best For — and When Should You Pick Friedrich 12PROG 75-100P FD HE EC3?

Evaluate whether Richmond 12GUH75-100FN's Gas-fired Storage Residential-duty Commercial architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Richmond 12GUH75-100FN logs 0.88 UEF (Pass: +0.30 / +51.7%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Richmond 12GUH75-100FN's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 199 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Richmond 12GUH75-100FN Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 75-100P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Common Homeowner Questions for Richmond 12GUH75-100FN

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Richmond 12GUH75-100FN (0.88 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Richmond 12GUH75-100FN records 0.88 UEF (Pass: +0.30 / +51.7%), placing #34 of 71 out of 71 certified Gas-fired Storage Residential-duty Commercial configurations.

Does Richmond 12GUH75-100FN fit inside a tight hallway closet or low-headroom utility room?

Richmond 12GUH75-100FN requires room for its 64.5 in. vertical shell and 26.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (26.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Richmond 12GUH75-100FN?

Installing Richmond 12GUH75-100FN on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for Richmond 12GUH75-100FN?

Rated 0.88 UEF on Natural Gas, Richmond 12GUH75-100FN carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas-fired Storage Residential-duty Commercial models.

What are the main drawbacks of Richmond 12GUH75-100FN (0.88 UEF)?

Buyers expecting endless simultaneous shower flow beyond 199 gal should compare condensing tankless units or larger-capacity tanks.

What hot-water delivery rating governs Richmond 12GUH75-100FN?

Rated for 199 gal FHR (+63 gal vs. 136 gal median), Richmond 12GUH75-100FN prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Richmond 12GUH75-100FN for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Richmond; use our browser-only serial decoder to inspect Richmond 12GUH75-100FN's age and warranty window.

What alternative models sit closest to Richmond 12GUH75-100FN in the Gas-fired Storage Residential-duty Commercial class?

Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks