Skip to main content
ENERGY STAR water heater model · PD 2408830

HTP PH100-80**** Water Heater Specifications (0.93 UEF)

The HTP PH100-80**** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.93 UEF rating across its 75-gallon nominal tank, 132 gal First Hour Rating, ranking #1 of 71 among 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models (PD 2408830). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.35 / +60.3%. Annual fuel cost depends on regional gas/fuel tariffs and needs >72 in. overhead clearance; clears 28 in. utility doorway (23" d). Closest certified alternative is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).

Uniform Energy Factor
0.93 UEF
Cohort UEF Rank
#1 of 71 (top 1.4%)
First Hour Rating
132 gal
Storage Volume
75 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.35 / +60.3%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking HTP PH100-80**** at 0.93 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58HTP PH100-80****: 0.93
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows HTP PH100-80**** relative to the cohort median.
Efficiency comparison & rule summary

HTP PH100-80**** (0.93 UEF) ranks #1 of 71 Gas-fired Storage Residential-duty Commercial models — top 1.4%, more efficient than 98.6% of Gas-fired Storage Residential-duty Commercial models, +0.05 UEF above the 0.88 UEF median.

Htp ph100-80**** stores 75 gal nominal; 132 gal first hour rating (-4 gal vs. 136 gal median); needs >72 in. overhead clearance; clears 28 in. utility doorway (23" d).

Peer comparison: HTP PH100-80**** (0.93 UEF) compares closely with Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF, delta -0.05) and Rheem PROPG75-100P RH HE EC3 (0.88 UEF, delta -0.05).

How Do HTP PH100-80**** Specs Compare to Gas-fired Storage Residential-duty Commercial Medians?

HTP PH100-80**** places #1 of 71 (top 1.4%) across 71 certified Gas-fired Storage Residential-duty Commercial configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandHTP6 certified listingsENERGY STAR PD 2408830
Model NumberPH100-80****Draw pattern: High-UsagePH100-80****
Uniform Energy Factor (UEF)0.93+0.05 UEF vs. 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)132 gal-4 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency99%+4.0 pts vs. 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)72" H x 23" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements1 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-12Certified 2024-11-12Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for HTP Water Heaters?

Zero active CPSC recalls matched HTP in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match PH100-80**** Most Closely?

These 5 competing Gas-fired Storage Residential-duty Commercial units sit nearest to HTP PH100-80**** by storage capacity and 0.93 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 75-100P FD HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.05) —
Rheem PROPG75-100P RH HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.05) —
Richmond 12GUH75-100FN Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.05) —
Ruud PROUG75-100P RU HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.05) —
Friedrich 12PROG 75-100U FD HE EC3 Gas-fired Storage Residential-duty Commercial 75 gal 199 gal 0.88 (-0.05) —

What Are the Limitations of HTP PH100-80**** and Who Should Not Install It?

Before ordering HTP PH100-80**** (Gas-fired Storage Residential-duty Commercial, 0.93 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • HTP PH100-80**** logs 0.93 UEF (Pass: +0.35 / +60.3%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect HTP PH100-80****'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 132 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for HTP PH100-80**** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 75-100P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

What Are the Key Questions About HTP PH100-80****?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does HTP PH100-80**** pass the May 6, 2029 federal DOE efficiency rule?

HTP PH100-80**** carries a verified 0.93 UEF rating (Pass: +0.35 / +60.3%), ranking #1 of 71 (top 1.4%) across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.

What doorway width and ceiling height does HTP PH100-80**** need?

HTP PH100-80**** stands 72 in. high with a 23 in. diameter; needs >72 in. overhead clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does HTP PH100-80**** require?

HTP PH100-80**** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does HTP PH100-80**** cost per year to run?

ENERGY STAR rates HTP PH100-80**** as a Natural Gas, Propane heater (0.93 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.

Who should NOT install HTP PH100-80****, and what are its limits?

HTP PH100-80**** (0.93 UEF) is not suited for multi-bath marathon draws exceeding its 132 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

How many bathrooms or people can HTP PH100-80**** serve at peak demand?

HTP PH100-80**** achieves a 132 gal First Hour Rating (-4 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for HTP PH100-80****?

No active CPSC recalls matched HTP as of 2026-11-23. Always decode the serial tag on HTP PH100-80**** because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to HTP PH100-80****, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks