HTP PH76-80**** Water Heater Specifications (0.87 UEF)
Certified at 0.87 UEF across its 77-gallon nominal tank, 206 gal First Hour Rating, HTP PH76-80**** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) places #61 of 71 out of 71 ENERGY STAR models (PD 2408476). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.29 / +50.0%. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (23" d). Closest certified alternative is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).
- Uniform Energy Factor
- 0.87 UEF
- Cohort UEF Rank
- #61 of 71
- First Hour Rating
- 206 gal
- Storage Volume
- 77 gal
- Fuel / Type
- Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
- DOE 2029 Rule Status
- Pass: +0.29 / +50.0%

Tested at 0.87 UEF, HTP PH76-80**** places #61 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations (-0.01 UEF vs. 0.88 UEF median).
Htp ph76-80**** stores 77 gal nominal; 206 gal first hour rating (+70 gal vs. 136 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (23" d).
Closest alternatives to HTP PH76-80**** include Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF, delta +0.01) alongside Rheem PROPG75-100P RH HE EC3 (0.88 UEF, delta +0.01).
Which Specs Set HTP PH76-80**** Apart From Cohort Averages?
Ranked #61 of 71 inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, HTP PH76-80**** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | HTP | 6 certified listings | ENERGY STAR PD 2408476 |
| Model Number | PH76-80**** | Draw pattern: High-Usage | PH76-80**** |
| Uniform Energy Factor (UEF) | 0.87 | -0.01 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 206 gal | +70 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 94% | -1.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 23" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 0.7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-12 | Certified 2024-11-12 | Markets: United States, Canada |
What Should HTP Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for HTP; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?
Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich 12PROG 75-100P FD HE EC3 | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (+0.01) | — |
| Rheem PROPG75-100P RH HE EC3 | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (+0.01) | — |
| Richmond 12GUH75-100FN | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (+0.01) | — |
| Ruud PROUG75-100P RU HE EC3 | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (+0.01) | — |
| Friedrich 12PROG 75-100U FD HE EC3 | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (+0.01) | — |
When Should Homeowners Skip HTP PH76-80**** (Gas-fired Storage Residential-duty Commercial)?
Check HTP PH76-80****'s mechanical constraints—including utility space, Natural Gas, Propane capacity, and Pass: +0.29 / +50.0% status—against typical residential installations.
Key Limitations & Exclusions
- HTP PH76-80**** logs 0.87 UEF (Pass: +0.29 / +50.0%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect HTP PH76-80****'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 206 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: HTP PH76-80****
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will HTP PH76-80**** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 0.87 UEF, HTP PH76-80**** shows Pass: +0.29 / +50.0% relative to May 6, 2029 federal DOE limits while placing #61 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers like Friedrich 12PROG 75-100P FD HE EC3.
Will HTP PH76-80**** fit through a standard utility door and 72-inch basement ceiling?
Measuring 69 in. tall by 23 in. diameter, HTP PH76-80**** notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support HTP PH76-80**** during replacement?
Fueled by Natural Gas, Propane, HTP PH76-80**** specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.
What is the estimated 10-year operating spend for HTP PH76-80****?
Because HTP PH76-80**** burns Natural Gas, Propane at 0.87 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 71 peers.
When is HTP PH76-80**** a poor fit for a residential replacement?
Avoid HTP PH76-80**** if household peak demand surpasses 206 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.
What First Hour Rating or flow capacity does HTP PH76-80**** deliver?
With 206 gal FHR (+70 gal vs. 136 gal median), HTP PH76-80**** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on HTP PH76-80****?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for HTP; verify exact manufacturing week for HTP PH76-80**** using the Serial Number Lookup tool.
Does HTP PH76-80**** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for HTP PH76-80****. Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)