John Wood JWHPCO-45 1**+JWXST-66TTP 1** Water Heater Specifications (3.7 UEF)
With PD 4529408 certification, John Wood JWHPCO-45 1**+JWXST-66TTP 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 60-gallon nominal tank, 82 gal First Hour Rating, standing #347 of 706 across 706 peers with Pass: +1.20 / +48.0% for May 6, 2029. Rated annual electricity draw of 1,341 kWh/yr equates to roughly $244/yr ($2,435 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).
- Uniform Energy Factor
- 3.7 UEF
- Cohort UEF Rank
- #347 of 706
- First Hour Rating
- 82 gal
- Storage Volume
- 60 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +48.0%

ENERGY STAR certification places John Wood JWHPCO-45 1**+JWXST-66TTP 1** at 3.7 UEF (#347 of 706; At 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: John Wood JWHPCO-45 1**+JWXST-66TTP 1** stands +1.20 UEF (+48.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,341 kWh/yr for John Wood JWHPCO-45 1**+JWXST-66TTP 1** runs ~$244/yr vs. ~$979/yr for a 0.92 UEF electric tank.
State electric sensitivity for John Wood JWHPCO-45 1**+JWXST-66TTP 1**: 10-year operating spend spans $1,962 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,327 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF, at parity) and American MHPCO-45 1**+MXST-66 1** (3.7 UEF, at parity) bracket John Wood JWHPCO-45 1**+JWXST-66TTP 1**.
Where Does John Wood JWHPCO-45 1**+JWXST-66TTP 1** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, John Wood JWHPCO-45 1**+JWXST-66TTP 1** holds #347 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | John Wood | 17 certified listings | ENERGY STAR PD 4529408 |
| Model Number | JWHPCO-45 1**+JWXST-66TTP 1** | Draw pattern: High-Usage | JWHPCO-45 1**+JWXST-66TTP 1** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,341 kWh/yr | +269 kWh/yr vs. 1,072 kWh/yr median | Est. $244/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 59" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-03-19 | Certified 2026-03-19 | Markets: United States, Canada |
How Much Electricity Does JWHPCO-45 1**+JWXST-66TTP 1** Use in Different States?
Estimated at $244/yr nationally (1,341 kWh/yr), 10-year utility spending for John Wood JWHPCO-45 1**+JWXST-66TTP 1** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $244/yr | $2,435 | $7,358 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $633/yr | $6,327 | $19,117 |
| California | 29.75 ¢/kWh ($0.2975) | $399/yr | $3,989 | $12,055 |
| Texas | 15.91 ¢/kWh ($0.1591) | $213/yr | $2,134 | $6,447 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $196/yr | $1,962 | $5,928 |
Does CPSC Flag Any Safety Notices on John Wood Units?
No open CPSC recall alerts appeared for John Wood as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to JWHPCO-45 1**+JWXST-66TTP 1**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to John Wood JWHPCO-45 1**+JWXST-66TTP 1**'s gallon capacity and 3.7 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| American MHPCO-45 1**+MXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| Giant GTHPCO-45 1**+GTXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| A. O. Smith HPACO-45 1**+AXST-66TTP 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
When Should Homeowners Skip John Wood JWHPCO-45 1**+JWXST-66TTP 1** (Hybrid/Electric Heat Pump)?
Check John Wood JWHPCO-45 1**+JWXST-66TTP 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.
Key Limitations & Exclusions
- John Wood JWHPCO-45 1**+JWXST-66TTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting John Wood JWHPCO-45 1**+JWXST-66TTP 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for John Wood JWHPCO-45 1**+JWXST-66TTP 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will John Wood JWHPCO-45 1**+JWXST-66TTP 1** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.7 UEF, John Wood JWHPCO-45 1**+JWXST-66TTP 1** shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPACO-45 1**+AXST-66 1**.
Will John Wood JWHPCO-45 1**+JWXST-66TTP 1** fit through a standard utility door and 72-inch basement ceiling?
Measuring 59 in. tall by 18 in. diameter, John Wood JWHPCO-45 1**+JWXST-66TTP 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support John Wood JWHPCO-45 1**+JWXST-66TTP 1** during replacement?
Electrical specs for John Wood JWHPCO-45 1**+JWXST-66TTP 1** call for 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for John Wood JWHPCO-45 1**+JWXST-66TTP 1**?
At 18.16 cents/kWh national residential pricing, John Wood JWHPCO-45 1**+JWXST-66TTP 1**'s 1,341 kWh/yr draw equals roughly $244 annually or $2,440 across a 10-year horizon (ranging from $196/yr in Washington hydro tiers up to $633/yr in Hawaii).
When is John Wood JWHPCO-45 1**+JWXST-66TTP 1** a poor fit for a residential replacement?
Avoid placing John Wood JWHPCO-45 1**+JWXST-66TTP 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does John Wood JWHPCO-45 1**+JWXST-66TTP 1** deliver?
With 82 gal FHR (+10 gal vs. 72 gal median), John Wood JWHPCO-45 1**+JWXST-66TTP 1** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on John Wood JWHPCO-45 1**+JWXST-66TTP 1**?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for John Wood; verify exact manufacturing week for John Wood JWHPCO-45 1**+JWXST-66TTP 1** using the Serial Number Lookup tool.
Does John Wood JWHPCO-45 1**+JWXST-66TTP 1** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for John Wood JWHPCO-45 1**+JWXST-66TTP 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)