Skip to main content
ENERGY STAR water heater model · PD 4689624

Lochinvar CHPA-50 2** Water Heater Specifications (3.68 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Lochinvar CHPA-50 2** (Electric) achieves a certified 3.68 UEF rating across its 46-gallon nominal tank, 65 gal First Hour Rating (rank #389 of 706, PD 4689624) and verifies as Pass: +1.38 / +60.0% for 2029 DOE floors. Rated annual electricity draw of 883 kWh/yr equates to roughly $160/yr ($1,604 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-50 2** (3.68 UEF).

Uniform Energy Factor
3.68 UEF
Cohort UEF Rank
#389 of 706
First Hour Rating
65 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.38 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar CHPA-50 2** at 3.68 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lochinvar CHPA-50 2**: 3.68
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar CHPA-50 2** relative to the cohort median.
Efficiency comparison & rule summary

Lochinvar CHPA-50 2** records 3.68 UEF efficiency, putting it #389 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Lochinvar CHPA-50 2** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.38 UEF (+60.0%). At EIA August 2026 national rates (18.16 cents/kWh), 883 kWh/yr for Lochinvar CHPA-50 2** runs ~$160/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar CHPA-50 2**: 10-year operating spend spans $1,292 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,166 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Lochinvar CHPA-50 2** (3.68 UEF) are A. O. Smith CAHP-50 2** (3.68 UEF, at parity) and American HPA10250H045DV 2** (3.68 UEF, at parity).

How Do Lochinvar CHPA-50 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

Lochinvar CHPA-50 2** places #389 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 4689624
Model NumberCHPA-50 2**Draw pattern: Medium-UsageCHPA-50 2**
Uniform Energy Factor (UEF)3.68-0.02 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use883 kWh/yr-189 kWh/yr vs. 1,072 kWh/yr medianEst. $160/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency416%-13.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-08-13Certified 2026-08-13Markets: United States

What Does CHPA-50 2** Cost to Operate Across State Electricity Rates?

At 883 kWh/yr, Lochinvar CHPA-50 2** runs roughly $160/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (883 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$160.00/yrHawaii$417.00/yrCalifornia$263.00/yrTexas$140.00/yrWashington$129.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $160/yr $1,604 $4,811
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $417/yr $4,166 $12,498
California 29.75 ¢/kWh ($0.2975) $263/yr $2,627 $7,881
Texas 15.91 ¢/kWh ($0.1591) $140/yr $1,405 $4,215
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $129/yr $1,292 $3,875
Estimated electricity spend (883 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Lochinvar Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 1 brand-level recall notice associated with Lochinvar; match your serial plate before repair. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Certified Water Heaters Match CHPA-50 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Lochinvar CHPA-50 2** by storage capacity and 3.68 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-50 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
American HPA10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
RELIANCE WATER HEATERS 10-50-DHPTA 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
State CSHP-50 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
A. O. Smith HPA10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883

Which Home Setups Are NOT a Fit for Lochinvar CHPA-50 2**?

Comparing Lochinvar CHPA-50 2** against A. O. Smith CAHP-50 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Lochinvar CHPA-50 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar CHPA-50 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar CHPA-50 2** Strong Fit — 3.68 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-50 2** footprint.

What Are the Key Questions About Lochinvar CHPA-50 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Lochinvar CHPA-50 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Lochinvar CHPA-50 2** logs 3.68 UEF (Pass: +1.38 / +60.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Lochinvar CHPA-50 2**?

With a 63 in. height and 15 in. diameter, Lochinvar CHPA-50 2** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Lochinvar CHPA-50 2**?

Powered via 240V at 22A max, Lochinvar CHPA-50 2** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Lochinvar CHPA-50 2**?

Annual electric spend for Lochinvar CHPA-50 2** (883 kWh/yr) averages $160/yr nationwide (ranging from $129/yr in Washington hydro tiers up to $417/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Lochinvar CHPA-50 2**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Lochinvar CHPA-50 2**.

Is Lochinvar CHPA-50 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Lochinvar CHPA-50 2** at 65 gal First Hour Rating (-7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Lochinvar have active CPSC SaferProducts notices affecting CHPA-50 2**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches Lochinvar CHPA-50 2** (3.68 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Lochinvar CHPA-50 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-50 2** (3.68 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks