Skip to main content
ENERGY STAR water heater model · PD 4689619

A. O. Smith CAHP-50 2** Water Heater Specifications (3.68 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith CAHP-50 2** (Electric) achieves a certified 3.68 UEF rating across its 46-gallon nominal tank, 65 gal First Hour Rating (rank #389 of 706, PD 4689619) and verifies as Pass: +1.38 / +60.0% for 2029 DOE floors. Rated annual electricity draw of 883 kWh/yr equates to roughly $160/yr ($1,604 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPA10250H045DV 2** (3.68 UEF).

Uniform Energy Factor
3.68 UEF
Cohort UEF Rank
#389 of 706
First Hour Rating
65 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.38 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith CAHP-50 2** at 3.68 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30A. O. Smith CAHP-50 2**: 3.68
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith CAHP-50 2** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith CAHP-50 2** records 3.68 UEF efficiency, putting it #389 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: A. O. Smith CAHP-50 2** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.38 UEF (+60.0%). At EIA August 2026 national rates (18.16 cents/kWh), 883 kWh/yr for A. O. Smith CAHP-50 2** runs ~$160/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith CAHP-50 2**: 10-year operating spend spans $1,292 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,166 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside A. O. Smith CAHP-50 2** (3.68 UEF) are American HPA10250H045DV 2** (3.68 UEF, at parity) and Lochinvar CHPA-50 2** (3.68 UEF, at parity).

How Do A. O. Smith CAHP-50 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

A. O. Smith CAHP-50 2** places #389 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4689619
Model NumberCAHP-50 2**Draw pattern: Medium-UsageCAHP-50 2**
Uniform Energy Factor (UEF)3.68-0.02 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use883 kWh/yr-189 kWh/yr vs. 1,072 kWh/yr medianEst. $160/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency416%-13.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-08-13Certified 2026-08-13Markets: United States

What Does CAHP-50 2** Cost to Operate Across State Electricity Rates?

At 883 kWh/yr, A. O. Smith CAHP-50 2** runs roughly $160/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (883 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$160.00/yrHawaii$417.00/yrCalifornia$263.00/yrTexas$140.00/yrWashington$129.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $160/yr $1,604 $4,811
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $417/yr $4,166 $12,498
California 29.75 ¢/kWh ($0.2975) $263/yr $2,627 $7,881
Texas 15.91 ¢/kWh ($0.1591) $140/yr $1,405 $4,215
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $129/yr $1,292 $3,875
Estimated electricity spend (883 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match CAHP-50 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith CAHP-50 2** by storage capacity and 3.68 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPA10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
Lochinvar CHPA-50 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
RELIANCE WATER HEATERS 10-50-DHPTA 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
State CSHP-50 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
Lochinvar HPPA050KD 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883

When Should Homeowners Skip A. O. Smith CAHP-50 2** (Hybrid/Electric Heat Pump)?

Check A. O. Smith CAHP-50 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.38 / +60.0% status—against typical residential installations.

Key Limitations & Exclusions

  • A. O. Smith CAHP-50 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith CAHP-50 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith CAHP-50 2** Strong Fit — 3.68 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPA10250H045DV 2** footprint.

What Are the Key Questions About A. O. Smith CAHP-50 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will A. O. Smith CAHP-50 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.68 UEF, A. O. Smith CAHP-50 2** shows Pass: +1.38 / +60.0% relative to May 6, 2029 federal DOE limits while placing #389 of 706 among 706 Hybrid/Electric Heat Pump peers like American HPA10250H045DV 2**.

Will A. O. Smith CAHP-50 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 63 in. tall by 15 in. diameter, A. O. Smith CAHP-50 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support A. O. Smith CAHP-50 2** during replacement?

Electrical specs for A. O. Smith CAHP-50 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for A. O. Smith CAHP-50 2**?

At 18.16 cents/kWh national residential pricing, A. O. Smith CAHP-50 2**'s 883 kWh/yr draw equals roughly $160 annually or $1,600 across a 10-year horizon (ranging from $129/yr in Washington hydro tiers up to $417/yr in Hawaii).

When is A. O. Smith CAHP-50 2** a poor fit for a residential replacement?

Avoid placing A. O. Smith CAHP-50 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does A. O. Smith CAHP-50 2** deliver?

With 65 gal FHR (-7 gal vs. 72 gal median), A. O. Smith CAHP-50 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on A. O. Smith CAHP-50 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does A. O. Smith CAHP-50 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith CAHP-50 2**. Closest peer in Hybrid/Electric Heat Pump is American HPA10250H045DV 2** (3.68 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks