Skip to main content
ENERGY STAR water heater model · PD 3417478

Lochinvar HPPA040KD 2** Water Heater Specifications (3.6 UEF)

With PD 3417478 certification, Lochinvar HPPA040KD 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.6 UEF rating across its 36-gallon nominal tank, 55 gal First Hour Rating, standing #401 of 706 across 706 peers with Pass: +1.30 / +56.5% for May 6, 2029. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-40 2** (3.6 UEF).

Uniform Energy Factor
3.6 UEF
Cohort UEF Rank
#401 of 706
First Hour Rating
55 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +56.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPPA040KD 2** at 3.6 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lochinvar HPPA040KD 2**: 3.60
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPPA040KD 2** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Lochinvar HPPA040KD 2** at 3.6 UEF (#401 of 706; -0.10 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Lochinvar HPPA040KD 2** stands +1.30 UEF (+56.5%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for Lochinvar HPPA040KD 2** runs ~$164/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar HPPA040KD 2**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith CAHP-40 2** (3.6 UEF, at parity) and American HPA10240H045DV 2** (3.6 UEF, at parity) bracket Lochinvar HPPA040KD 2**.

Where Does Lochinvar HPPA040KD 2** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Lochinvar HPPA040KD 2** holds #401 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 3417478
Model NumberHPPA040KD 2**Draw pattern: Medium-UsageHPPA040KD 2**
Uniform Energy Factor (UEF)3.6-0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)55 gal-17 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use902 kWh/yr-170 kWh/yr vs. 1,072 kWh/yr medianEst. $164/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency426%-3.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)66" H x 20" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Much Electricity Does HPPA040KD 2** Use in Different States?

Estimated at $164/yr nationally (902 kWh/yr), 10-year utility spending for Lochinvar HPPA040KD 2** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (902 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$164.00/yrHawaii$426.00/yrCalifornia$268.00/yrTexas$144.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $164/yr $1,638 $4,772
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $426/yr $4,256 $12,399
California 29.75 ¢/kWh ($0.2975) $268/yr $2,683 $7,818
Texas 15.91 ¢/kWh ($0.1591) $144/yr $1,435 $4,181
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,320 $3,845
Estimated electricity spend (902 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Lochinvar Units?

Checking 2026-11-23 SaferProducts data shows 1 notice mentioning Lochinvar; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPPA040KD 2**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Lochinvar HPPA040KD 2**'s gallon capacity and 3.6 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
American HPA10240H045DV 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
RELIANCE WATER HEATERS 10-40-DHPTA 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
State CSHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
A. O. Smith HPA10-40H45DV 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902

What Installation Caveats Apply Before Buying Lochinvar HPPA040KD 2**?

Even high-UEF units like Lochinvar HPPA040KD 2** (3.6 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Lochinvar HPPA040KD 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar HPPA040KD 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPPA040KD 2** Strong Fit — 3.6 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-40 2** footprint.

Common Homeowner Questions for Lochinvar HPPA040KD 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Lochinvar HPPA040KD 2** eligible for continued manufacture past May 6, 2029?

At 3.6 UEF, Lochinvar HPPA040KD 2** achieves Pass: +1.30 / +56.5% for the 2029 DOE standard and stands #401 of 706 against A. O. Smith CAHP-40 2** and American HPA10240H045DV 2**.

How tall and wide is Lochinvar HPPA040KD 2**, and what service clearance is needed?

Physical dimensions for Lochinvar HPPA040KD 2** are 66 in. height and 20 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (20" d)); verify stair turns and drain pan width before delivery.

Will Lochinvar HPPA040KD 2** require upgrading household electrical panels or gas piping?

Lochinvar HPPA040KD 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Lochinvar HPPA040KD 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $164/yr ($1,640 over 10 years) to power Lochinvar HPPA040KD 2** at 902 kWh/yr under the 18.16 cents/kWh US average (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii).

Which installation bottlenecks limit Lochinvar HPPA040KD 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Lochinvar HPPA040KD 2** drops into resistance mode more often.

How does Lochinvar HPPA040KD 2** handle simultaneous showers and laundry?

Delivering 55 gal in the first hour (-17 gal vs. 72 gal median), Lochinvar HPPA040KD 2** combines 36 gal tank storage with rapid burner/element recovery.

How long is the warranty on Lochinvar HPPA040KD 2** and how do you decode its serial?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Lochinvar HPPA040KD 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-40 2** (3.6 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks