ENERGY STAR water heater model · PD 3417487

Lochinvar HPPA050KD 2** Water Heater Specifications (3.68 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Lochinvar HPPA050KD 2** achieves a certified 3.68 UEF rating across its 46-gallon nominal tank, 65 gal First Hour Rating and ranks #389 of 706 in its 706-model cohort (PD 3417487), recording Pass: +1.38 / +60.0% under 2029 DOE rules. Rated annual electricity draw of 883 kWh/yr equates to roughly $160/yr ($1,604 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-50 2** (3.68 UEF).

Uniform Energy Factor
3.68 UEF
Cohort UEF Rank
#389 of 706
First Hour Rating
65 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.38 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPPA050KD 2** at 3.68 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lochinvar HPPA050KD 2**: 3.68
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPPA050KD 2** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Lochinvar HPPA050KD 2** logs 3.68 UEF and ranks #389 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Lochinvar HPPA050KD 2** holds a +1.38 UEF (+60.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 883 kWh/yr for Lochinvar HPPA050KD 2** runs ~$160/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar HPPA050KD 2**: 10-year operating spend spans $1,292 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,166 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Lochinvar HPPA050KD 2** (3.68 UEF)? Check A. O. Smith CAHP-50 2** (3.68 UEF, at parity) and American HPA10250H045DV 2** (3.68 UEF, at parity).

What Physical and Thermal Ratings Define Lochinvar HPPA050KD 2**?

Positioning at #389 of 706 out of 706 Hybrid/Electric Heat Pump peers, Lochinvar HPPA050KD 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 3417487
Model NumberHPPA050KD 2**Draw pattern: Medium-UsageHPPA050KD 2**
Uniform Energy Factor (UEF)3.68-0.02 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use883 kWh/yr-189 kWh/yr vs. 1,072 kWh/yr medianEst. $160/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency416%-13.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

Why Do State Utility Rates Shift HPPA050KD 2** Running Costs?

Consuming 883 kWh annually puts Lochinvar HPPA050KD 2** near $160/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (883 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$160.00/yrHawaii$417.00/yrCalifornia$263.00/yrTexas$140.00/yrWashington$129.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $160/yr $1,604 $4,811
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $417/yr $4,166 $12,498
California 29.75 ¢/kWh ($0.2975) $263/yr $2,627 $7,881
Texas 15.91 ¢/kWh ($0.1591) $140/yr $1,405 $4,215
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $129/yr $1,292 $3,875
Estimated electricity spend (883 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Lochinvar Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 1 brand notice under Lochinvar; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

What Are 5 Direct Alternatives to Lochinvar HPPA050KD 2**?

Homeowners cross-shopping Lochinvar HPPA050KD 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-50 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
American HPA10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
RELIANCE WATER HEATERS 10-50-DHPTA 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
State CSHP-50 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883
A. O. Smith HPA10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.68 (at parity) 883

What Installation Caveats Apply Before Buying Lochinvar HPPA050KD 2**?

Even high-UEF units like Lochinvar HPPA050KD 2** (3.68 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Lochinvar HPPA050KD 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar HPPA050KD 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPPA050KD 2** Strong Fit — 3.68 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-50 2** footprint.

Sizing, Efficiency & Recall Answers for Lochinvar HPPA050KD 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Lochinvar HPPA050KD 2** eligible for continued manufacture past May 6, 2029?

At 3.68 UEF, Lochinvar HPPA050KD 2** achieves Pass: +1.38 / +60.0% for the 2029 DOE standard and stands #389 of 706 against A. O. Smith CAHP-50 2** and American HPA10250H045DV 2**.

How tall and wide is Lochinvar HPPA050KD 2**, and what service clearance is needed?

Physical dimensions for Lochinvar HPPA050KD 2** are 63 in. height and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)); verify stair turns and drain pan width before delivery.

Will Lochinvar HPPA050KD 2** require upgrading household electrical panels or gas piping?

Lochinvar HPPA050KD 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Lochinvar HPPA050KD 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $160/yr ($1,600 over 10 years) to power Lochinvar HPPA050KD 2** at 883 kWh/yr under the 18.16 cents/kWh US average (ranging from $129/yr in Washington hydro tiers up to $417/yr in Hawaii).

Which installation bottlenecks limit Lochinvar HPPA050KD 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Lochinvar HPPA050KD 2** drops into resistance mode more often.

How does Lochinvar HPPA050KD 2** handle simultaneous showers and laundry?

Delivering 65 gal in the first hour (-7 gal vs. 72 gal median), Lochinvar HPPA050KD 2** combines 46 gal tank storage with rapid burner/element recovery.

How long is the warranty on Lochinvar HPPA050KD 2** and how do you decode its serial?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Lochinvar HPPA050KD 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-50 2** (3.68 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks