Skip to main content
ENERGY STAR water heater model · PD 4682178

Midea CAN3-RSJ-15/300RDVN3-L4 Water Heater Specifications (4 UEF)

With PD 4682178 certification, Midea CAN3-RSJ-15/300RDVN3-L4 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First Hour Rating, standing #106 of 706 across 706 peers with Pass: +1.50 / +60.0% for May 6, 2029. Rated annual electricity draw of 1,230 kWh/yr equates to roughly $223/yr ($2,234 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP80 (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
75 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea CAN3-RSJ-15/300RDVN3-L4 at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Midea CAN3-RSJ-15/300RDVN3-L4: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea CAN3-RSJ-15/300RDVN3-L4 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Midea CAN3-RSJ-15/300RDVN3-L4 at 4.0 UEF (#106 of 706; +0.30 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Midea CAN3-RSJ-15/300RDVN3-L4 stands +1.50 UEF (+60.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,230 kWh/yr for Midea CAN3-RSJ-15/300RDVN3-L4 runs ~$223/yr vs. ~$971/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea CAN3-RSJ-15/300RDVN3-L4: 10-year operating spend spans $1,799 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,803 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Rinnai REHP80 (4.0 UEF, at parity) and Bradford White RE2HP80**-1NCTT (4.0 UEF, at parity) bracket Midea CAN3-RSJ-15/300RDVN3-L4.

Where Does Midea CAN3-RSJ-15/300RDVN3-L4 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Midea CAN3-RSJ-15/300RDVN3-L4 holds #106 of 706 (top 19.8%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 4682178
Model NumberCAN3-RSJ-15/300RDVN3-L4Draw pattern: High-UsageCAN3-RSJ-15/300RDVN3-L4
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,230 kWh/yr+158 kWh/yr vs. 1,072 kWh/yr medianEst. $223/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-07-31Certified 2026-07-31Markets: United States, Canada

How Much Electricity Does CAN3-RSJ-15/300RDVN3-L4 Use in Different States?

Estimated at $223/yr nationally (1,230 kWh/yr), 10-year utility spending for Midea CAN3-RSJ-15/300RDVN3-L4 shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,230 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$223.00/yrHawaii$580.00/yrCalifornia$366.00/yrTexas$196.00/yrWashington$180.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $223/yr $2,234 $7,478
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $580/yr $5,803 $19,429
California 29.75 ¢/kWh ($0.2975) $366/yr $3,659 $12,251
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,957 $6,552
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $180/yr $1,799 $6,025
Estimated electricity spend (1,230 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Midea Units?

No open CPSC recall alerts appeared for Midea as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to CAN3-RSJ-15/300RDVN3-L4?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Midea CAN3-RSJ-15/300RDVN3-L4's gallon capacity and 4.0 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rinnai REHP80 Hybrid/Electric Heat Pump 75 gal 91 gal 4.0 (at parity) 1,225
Bradford White RE2HP80**-1NCTT Hybrid/Electric Heat Pump 75 gal 88 gal 4.0 (at parity) 1,240
JETGLAS RE2HP80*-1NCTT Hybrid/Electric Heat Pump 75 gal 88 gal 4.0 (at parity) 1,240
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Rinnai REHP80BM Hybrid/Electric Heat Pump 75 gal 91 gal 4.0 (at parity) 1,225

What Installation Caveats Apply Before Buying Midea CAN3-RSJ-15/300RDVN3-L4?

Even high-UEF units like Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Midea CAN3-RSJ-15/300RDVN3-L4 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea CAN3-RSJ-15/300RDVN3-L4 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea CAN3-RSJ-15/300RDVN3-L4 Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rinnai REHP80 footprint.

Common Homeowner Questions for Midea CAN3-RSJ-15/300RDVN3-L4

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Midea CAN3-RSJ-15/300RDVN3-L4 eligible for continued manufacture past May 6, 2029?

At 4.0 UEF, Midea CAN3-RSJ-15/300RDVN3-L4 achieves Pass: +1.50 / +60.0% for the 2029 DOE standard and stands #106 of 706 (top 19.8%) against Rinnai REHP80 and Bradford White RE2HP80**-1NCTT.

How tall and wide is Midea CAN3-RSJ-15/300RDVN3-L4, and what service clearance is needed?

Physical dimensions for Midea CAN3-RSJ-15/300RDVN3-L4 are 41.7 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

Will Midea CAN3-RSJ-15/300RDVN3-L4 require upgrading household electrical panels or gas piping?

Midea CAN3-RSJ-15/300RDVN3-L4 draws 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Midea CAN3-RSJ-15/300RDVN3-L4 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $223/yr ($2,230 over 10 years) to power Midea CAN3-RSJ-15/300RDVN3-L4 at 1,230 kWh/yr under the 18.16 cents/kWh US average (ranging from $180/yr in Washington hydro tiers up to $580/yr in Hawaii).

Which installation bottlenecks limit Midea CAN3-RSJ-15/300RDVN3-L4?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Midea CAN3-RSJ-15/300RDVN3-L4 drops into resistance mode more often.

How does Midea CAN3-RSJ-15/300RDVN3-L4 handle simultaneous showers and laundry?

Delivering 91 gal in the first hour (+19 gal vs. 72 gal median), Midea CAN3-RSJ-15/300RDVN3-L4 combines 75 gal tank storage with rapid burner/element recovery.

How long is the warranty on Midea CAN3-RSJ-15/300RDVN3-L4 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Midea as of 2026-11-23. Confirm install proof and serial manufacture year on Midea CAN3-RSJ-15/300RDVN3-L4 before calling service.

How do 2026 post-OBBBA rebates affect buying Midea CAN3-RSJ-15/300RDVN3-L4?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP80 (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks