Skip to main content
ENERGY STAR water heater model · PD 3462859

Rinnai REHP80BM Water Heater Specifications (4 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Rinnai REHP80BM (Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First Hour Rating (rank #106 of 706, PD 3462859) and verifies as Pass: +1.50 / +60.0% for 2029 DOE floors. Rated annual electricity draw of 1,225 kWh/yr equates to roughly $222/yr ($2,225 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
75 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rinnai REHP80BM at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rinnai REHP80BM: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rinnai REHP80BM relative to the cohort median.
Efficiency comparison & rule summary

Rinnai REHP80BM records 4.0 UEF efficiency, putting it #106 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Rinnai REHP80BM exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.50 UEF (+60.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,225 kWh/yr for Rinnai REHP80BM runs ~$222/yr vs. ~$967/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Rinnai REHP80BM: 10-year operating spend spans $1,792 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,780 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Rinnai REHP80BM (4.0 UEF) are Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF, at parity) and Bradford White RE2HP80**-1NCTT (4.0 UEF, at parity).

Which Specs Set Rinnai REHP80BM Apart From Cohort Averages?

Ranked #106 of 706 (top 19.8%) inside the 706-model Hybrid/Electric Heat Pump cohort, Rinnai REHP80BM is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRinnai25 certified listingsENERGY STAR PD 3462859
Model NumberREHP80BMDraw pattern: High-UsageREHP80BM
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,225 kWh/yr+153 kWh/yr vs. 1,072 kWh/yr medianEst. $222/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency454%+25.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 25.7" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (25.7" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-03-24Certified 2026-03-24Markets: United States, Canada

How Do Regional kWh Prices Impact REHP80BM Over 10 Years?

Using EIA Table 5.6.A benchmarks, Rinnai REHP80BM's 1,225 kWh/yr draw translates to roughly $222/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,225 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$222.00/yrHawaii$578.00/yrCalifornia$364.00/yrTexas$195.00/yrWashington$179.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $222/yr $2,225 $7,447
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $578/yr $5,780 $19,349
California 29.75 ¢/kWh ($0.2975) $364/yr $3,644 $12,200
Texas 15.91 ¢/kWh ($0.1591) $195/yr $1,949 $6,525
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $179/yr $1,792 $6,000
Estimated electricity spend (1,225 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Rinnai Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Rinnai; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Midea CAN3-RSJ-15/300RDVN3-L4 Hybrid/Electric Heat Pump 75 gal 91 gal 4.0 (at parity) 1,230
Bradford White RE2HP80**-1NCTT Hybrid/Electric Heat Pump 75 gal 88 gal 4.0 (at parity) 1,240
JETGLAS RE2HP80*-1NCTT Hybrid/Electric Heat Pump 75 gal 88 gal 4.0 (at parity) 1,240
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Midea MAHW-80VN3B Hybrid/Electric Heat Pump 75 gal 91 gal 4.0 (at parity) 1,230

When Should Homeowners Skip Rinnai REHP80BM (Hybrid/Electric Heat Pump)?

Check Rinnai REHP80BM's mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +60.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Rinnai REHP80BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rinnai REHP80BM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rinnai REHP80BM Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Midea CAN3-RSJ-15/300RDVN3-L4 footprint.

Frequently Asked Technical Questions: Rinnai REHP80BM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Rinnai REHP80BM stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.0 UEF, Rinnai REHP80BM shows Pass: +1.50 / +60.0% relative to May 6, 2029 federal DOE limits while placing #106 of 706 (top 19.8%) among 706 Hybrid/Electric Heat Pump peers like Midea CAN3-RSJ-15/300RDVN3-L4.

Will Rinnai REHP80BM fit through a standard utility door and 72-inch basement ceiling?

Measuring 74.2 in. tall by 25.7 in. diameter, Rinnai REHP80BM notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (25.7" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Rinnai REHP80BM during replacement?

Electrical specs for Rinnai REHP80BM call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Rinnai REHP80BM?

At 18.16 cents/kWh national residential pricing, Rinnai REHP80BM's 1,225 kWh/yr draw equals roughly $222 annually or $2,220 across a 10-year horizon (ranging from $179/yr in Washington hydro tiers up to $578/yr in Hawaii).

When is Rinnai REHP80BM a poor fit for a residential replacement?

Avoid placing Rinnai REHP80BM directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Rinnai REHP80BM deliver?

With 91 gal FHR (+19 gal vs. 72 gal median), Rinnai REHP80BM fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Rinnai REHP80BM?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Rinnai; verify exact manufacturing week for Rinnai REHP80BM using the Serial Number Lookup tool.

Does Rinnai REHP80BM qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rinnai REHP80BM. Closest peer in Hybrid/Electric Heat Pump is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks