Rinnai REHP80BM Water Heater Specifications (4 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Rinnai REHP80BM (Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First Hour Rating (rank #106 of 706, PD 3462859) and verifies as Pass: +1.50 / +60.0% for 2029 DOE floors. Rated annual electricity draw of 1,225 kWh/yr equates to roughly $222/yr ($2,225 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).
- Uniform Energy Factor
- 4.0 UEF
- Cohort UEF Rank
- #106 of 706 (top 19.8%)
- First Hour Rating
- 91 gal
- Storage Volume
- 75 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.50 / +60.0%

Rinnai REHP80BM records 4.0 UEF efficiency, putting it #106 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Rinnai REHP80BM exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.50 UEF (+60.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,225 kWh/yr for Rinnai REHP80BM runs ~$222/yr vs. ~$967/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Rinnai REHP80BM: 10-year operating spend spans $1,792 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,780 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Rinnai REHP80BM (4.0 UEF) are Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF, at parity) and Bradford White RE2HP80**-1NCTT (4.0 UEF, at parity).
Which Specs Set Rinnai REHP80BM Apart From Cohort Averages?
Ranked #106 of 706 (top 19.8%) inside the 706-model Hybrid/Electric Heat Pump cohort, Rinnai REHP80BM is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rinnai | 25 certified listings | ENERGY STAR PD 3462859 |
| Model Number | REHP80BM | Draw pattern: High-Usage | REHP80BM |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 91 gal | +19 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,225 kWh/yr | +153 kWh/yr vs. 1,072 kWh/yr median | Est. $222/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 454% | +25.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 25.7" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (25.7" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2026-03-24 | Certified 2026-03-24 | Markets: United States, Canada |
How Do Regional kWh Prices Impact REHP80BM Over 10 Years?
Using EIA Table 5.6.A benchmarks, Rinnai REHP80BM's 1,225 kWh/yr draw translates to roughly $222/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $222/yr | $2,225 | $7,447 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $578/yr | $5,780 | $19,349 |
| California | 29.75 ¢/kWh ($0.2975) | $364/yr | $3,644 | $12,200 |
| Texas | 15.91 ¢/kWh ($0.1591) | $195/yr | $1,949 | $6,525 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $179/yr | $1,792 | $6,000 |
What Should Rinnai Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Rinnai; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Midea CAN3-RSJ-15/300RDVN3-L4 | Hybrid/Electric Heat Pump | 75 gal | 91 gal | 4.0 (at parity) | 1,230 |
| Bradford White RE2HP80**-1NCTT | Hybrid/Electric Heat Pump | 75 gal | 88 gal | 4.0 (at parity) | 1,240 |
| JETGLAS RE2HP80*-1NCTT | Hybrid/Electric Heat Pump | 75 gal | 88 gal | 4.0 (at parity) | 1,240 |
| 1HVAC ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| Midea MAHW-80VN3B | Hybrid/Electric Heat Pump | 75 gal | 91 gal | 4.0 (at parity) | 1,230 |
When Should Homeowners Skip Rinnai REHP80BM (Hybrid/Electric Heat Pump)?
Check Rinnai REHP80BM's mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +60.0% status—against typical residential installations.
Key Limitations & Exclusions
- Rinnai REHP80BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rinnai REHP80BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Rinnai REHP80BM
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Rinnai REHP80BM stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 4.0 UEF, Rinnai REHP80BM shows Pass: +1.50 / +60.0% relative to May 6, 2029 federal DOE limits while placing #106 of 706 (top 19.8%) among 706 Hybrid/Electric Heat Pump peers like Midea CAN3-RSJ-15/300RDVN3-L4.
Will Rinnai REHP80BM fit through a standard utility door and 72-inch basement ceiling?
Measuring 74.2 in. tall by 25.7 in. diameter, Rinnai REHP80BM notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (25.7" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Rinnai REHP80BM during replacement?
Electrical specs for Rinnai REHP80BM call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Rinnai REHP80BM?
At 18.16 cents/kWh national residential pricing, Rinnai REHP80BM's 1,225 kWh/yr draw equals roughly $222 annually or $2,220 across a 10-year horizon (ranging from $179/yr in Washington hydro tiers up to $578/yr in Hawaii).
When is Rinnai REHP80BM a poor fit for a residential replacement?
Avoid placing Rinnai REHP80BM directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Rinnai REHP80BM deliver?
With 91 gal FHR (+19 gal vs. 72 gal median), Rinnai REHP80BM fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Rinnai REHP80BM?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Rinnai; verify exact manufacturing week for Rinnai REHP80BM using the Serial Number Lookup tool.
Does Rinnai REHP80BM qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rinnai REHP80BM. Closest peer in Hybrid/Electric Heat Pump is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)