Skip to main content
ENERGY STAR water heater model · PD 3543847

Midea MAHW-80VN3A Water Heater Specifications (4 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Midea MAHW-80VN3A achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating and ranks #106 of 706 in its 706-model cohort (PD 3543847), recording Pass: +1.50 / +60.0% under 2029 DOE rules. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
74 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea MAHW-80VN3A at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Midea MAHW-80VN3A: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea MAHW-80VN3A relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Midea MAHW-80VN3A logs 4.0 UEF and ranks #106 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Midea MAHW-80VN3A holds a +1.50 UEF (+60.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Midea MAHW-80VN3A runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea MAHW-80VN3A: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Midea MAHW-80VN3A (4.0 UEF)? Check 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity).

Where Does Midea MAHW-80VN3A Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Midea MAHW-80VN3A holds #106 of 706 (top 19.8%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 3543847
Model NumberMAHW-80VN3ADraw pattern: High-UsageMAHW-80VN3A
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-04Certified 2024-11-04Markets: United States, Canada

How Much Electricity Does MAHW-80VN3A Use in Different States?

Estimated at $225/yr nationally (1,240 kWh/yr), 10-year utility spending for Midea MAHW-80VN3A shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,538
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $19,584
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $12,349
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,604
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $6,073
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Midea Units?

No open CPSC recall alerts appeared for Midea as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to MAHW-80VN3A?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Midea MAHW-80VN3A's gallon capacity and 4.0 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
ACIQ ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80CA Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Custom Comfort CCOHPWH80A Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80US Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240

When Should Homeowners Skip Midea MAHW-80VN3A (Hybrid/Electric Heat Pump)?

Check Midea MAHW-80VN3A's mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +60.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Midea MAHW-80VN3A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea MAHW-80VN3A directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea MAHW-80VN3A Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-80G-HP-WH footprint.

Common Homeowner Questions for Midea MAHW-80VN3A

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Midea MAHW-80VN3A stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.0 UEF, Midea MAHW-80VN3A shows Pass: +1.50 / +60.0% relative to May 6, 2029 federal DOE limits while placing #106 of 706 (top 19.8%) among 706 Hybrid/Electric Heat Pump peers like 1HVAC ACIQ-80G-HP-WH.

Will Midea MAHW-80VN3A fit through a standard utility door and 72-inch basement ceiling?

Measuring 41.7 in. tall by 21.8 in. diameter, Midea MAHW-80VN3A notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Midea MAHW-80VN3A during replacement?

Electrical specs for Midea MAHW-80VN3A call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Midea MAHW-80VN3A?

At 18.16 cents/kWh national residential pricing, Midea MAHW-80VN3A's 1,240 kWh/yr draw equals roughly $225 annually or $2,250 across a 10-year horizon (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).

When is Midea MAHW-80VN3A a poor fit for a residential replacement?

Avoid placing Midea MAHW-80VN3A directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Midea MAHW-80VN3A deliver?

With 91 gal FHR (+19 gal vs. 72 gal median), Midea MAHW-80VN3A fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Midea MAHW-80VN3A?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Midea; verify exact manufacturing week for Midea MAHW-80VN3A using the Serial Number Lookup tool.

Does Midea MAHW-80VN3A qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Midea MAHW-80VN3A. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks