Skip to main content
ENERGY STAR water heater model · PD 4682184

Midea MAHW-80VN3B Water Heater Specifications (4 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Midea MAHW-80VN3B (Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First Hour Rating (rank #106 of 706, PD 4682184) and verifies as Pass: +1.50 / +60.0% for 2029 DOE floors. Rated annual electricity draw of 1,230 kWh/yr equates to roughly $223/yr ($2,234 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP80 (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
75 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea MAHW-80VN3B at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Midea MAHW-80VN3B: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea MAHW-80VN3B relative to the cohort median.
Efficiency comparison & rule summary

Midea MAHW-80VN3B records 4.0 UEF efficiency, putting it #106 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Midea MAHW-80VN3B exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.50 UEF (+60.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,230 kWh/yr for Midea MAHW-80VN3B runs ~$223/yr vs. ~$971/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea MAHW-80VN3B: 10-year operating spend spans $1,799 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,803 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Midea MAHW-80VN3B (4.0 UEF) are Rinnai REHP80 (4.0 UEF, at parity) and Bradford White RE2HP80**-1NCTT (4.0 UEF, at parity).

What Physical and Thermal Ratings Define Midea MAHW-80VN3B?

Positioning at #106 of 706 (top 19.8%) out of 706 Hybrid/Electric Heat Pump peers, Midea MAHW-80VN3B pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 4682184
Model NumberMAHW-80VN3BDraw pattern: High-UsageMAHW-80VN3B
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,230 kWh/yr+158 kWh/yr vs. 1,072 kWh/yr medianEst. $223/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-07-31Certified 2026-07-31Markets: United States, Canada

Why Do State Utility Rates Shift MAHW-80VN3B Running Costs?

Consuming 1,230 kWh annually puts Midea MAHW-80VN3B near $223/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,230 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$223.00/yrHawaii$580.00/yrCalifornia$366.00/yrTexas$196.00/yrWashington$180.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $223/yr $2,234 $7,478
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $580/yr $5,803 $19,429
California 29.75 ¢/kWh ($0.2975) $366/yr $3,659 $12,251
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,957 $6,552
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $180/yr $1,799 $6,025
Estimated electricity spend (1,230 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Midea Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Midea; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Midea MAHW-80VN3B?

Homeowners cross-shopping Midea MAHW-80VN3B frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rinnai REHP80 Hybrid/Electric Heat Pump 75 gal 91 gal 4.0 (at parity) 1,225
Bradford White RE2HP80**-1NCTT Hybrid/Electric Heat Pump 75 gal 88 gal 4.0 (at parity) 1,240
JETGLAS RE2HP80*-1NCTT Hybrid/Electric Heat Pump 75 gal 88 gal 4.0 (at parity) 1,240
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Rinnai REHP80BM Hybrid/Electric Heat Pump 75 gal 91 gal 4.0 (at parity) 1,225

When Should Homeowners Skip Midea MAHW-80VN3B (Hybrid/Electric Heat Pump)?

Check Midea MAHW-80VN3B's mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +60.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Midea MAHW-80VN3B needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea MAHW-80VN3B directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea MAHW-80VN3B Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rinnai REHP80 footprint.

Sizing, Efficiency & Recall Answers for Midea MAHW-80VN3B

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Midea MAHW-80VN3B stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.0 UEF, Midea MAHW-80VN3B shows Pass: +1.50 / +60.0% relative to May 6, 2029 federal DOE limits while placing #106 of 706 (top 19.8%) among 706 Hybrid/Electric Heat Pump peers like Rinnai REHP80.

Will Midea MAHW-80VN3B fit through a standard utility door and 72-inch basement ceiling?

Measuring 41.7 in. tall by 21.8 in. diameter, Midea MAHW-80VN3B notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Midea MAHW-80VN3B during replacement?

Electrical specs for Midea MAHW-80VN3B call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Midea MAHW-80VN3B?

At 18.16 cents/kWh national residential pricing, Midea MAHW-80VN3B's 1,230 kWh/yr draw equals roughly $223 annually or $2,230 across a 10-year horizon (ranging from $180/yr in Washington hydro tiers up to $580/yr in Hawaii).

When is Midea MAHW-80VN3B a poor fit for a residential replacement?

Avoid placing Midea MAHW-80VN3B directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Midea MAHW-80VN3B deliver?

With 91 gal FHR (+19 gal vs. 72 gal median), Midea MAHW-80VN3B fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Midea MAHW-80VN3B?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Midea; verify exact manufacturing week for Midea MAHW-80VN3B using the Serial Number Lookup tool.

Does Midea MAHW-80VN3B qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Midea MAHW-80VN3B. Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP80 (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks