Skip to main content
ENERGY STAR water heater model · PD 3722157

Midea MAWH80D2AKH Water Heater Specifications (4 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Midea MAWH80D2AKH achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating and ranks #106 of 706 in its 706-model cohort (PD 3722157), recording Pass: +1.50 / +60.0% under 2029 DOE rules. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
74 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea MAWH80D2AKH at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Midea MAWH80D2AKH: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea MAWH80D2AKH relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Midea MAWH80D2AKH logs 4.0 UEF and ranks #106 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Midea MAWH80D2AKH holds a +1.50 UEF (+60.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Midea MAWH80D2AKH runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea MAWH80D2AKH: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Midea MAWH80D2AKH (4.0 UEF)? Check 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity).

How Do Midea MAWH80D2AKH Specs Compare to Hybrid/Electric Heat Pump Medians?

Midea MAWH80D2AKH places #106 of 706 (top 19.8%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 3722157
Model NumberMAWH80D2AKHDraw pattern: High-UsageMAWH80D2AKH
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-04Certified 2024-11-04Markets: United States, Canada

What Does MAWH80D2AKH Cost to Operate Across State Electricity Rates?

At 1,240 kWh/yr, Midea MAWH80D2AKH runs roughly $225/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,538
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $19,584
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $12,349
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,604
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $6,073
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Midea Water Heaters?

Zero active CPSC recalls matched Midea in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match MAWH80D2AKH Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Midea MAWH80D2AKH by storage capacity and 4.0 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
ACIQ ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80CA Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Custom Comfort CCOHPWH80A Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80US Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240

What Are the Limitations of Midea MAWH80D2AKH and Who Should Not Install It?

Before ordering Midea MAWH80D2AKH (Hybrid/Electric Heat Pump, 4.0 UEF), weigh space clearances, fuel piping, noise (49 dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Midea MAWH80D2AKH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea MAWH80D2AKH directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea MAWH80D2AKH Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-80G-HP-WH footprint.

What Are the Key Questions About Midea MAWH80D2AKH?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Midea MAWH80D2AKH pass the May 6, 2029 federal DOE efficiency rule?

Midea MAWH80D2AKH carries a verified 4.0 UEF rating (Pass: +1.50 / +60.0%), ranking #106 of 706 (top 19.8%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Midea MAWH80D2AKH need?

Midea MAWH80D2AKH stands 41.7 in. high with a 21.8 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Midea MAWH80D2AKH require?

Midea MAWH80D2AKH uses a 240V branch circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Midea MAWH80D2AKH cost per year to run?

Rated at 1,240 kWh/yr, Midea MAWH80D2AKH costs about $225/yr ($2,250 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).

Who should NOT install Midea MAWH80D2AKH, and what are its limits?

Midea MAWH80D2AKH (4.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Midea MAWH80D2AKH serve at peak demand?

Midea MAWH80D2AKH achieves a 91 gal First Hour Rating (+19 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Midea MAWH80D2AKH?

No active CPSC recalls matched Midea as of 2026-11-23. Always decode the serial tag on Midea MAWH80D2AKH because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Midea MAWH80D2AKH, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks