Skip to main content
ENERGY STAR water heater model · PD 3543522

Midea US3-RSJ-15/300RDVN3-L3 Water Heater Specifications (4 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Midea US3-RSJ-15/300RDVN3-L3 achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating and ranks #106 of 706 in its 706-model cohort (PD 3543522), recording Pass: +1.50 / +60.0% under 2029 DOE rules. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
74 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea US3-RSJ-15/300RDVN3-L3 at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Midea US3-RSJ-15/300RDVN3-L3: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea US3-RSJ-15/300RDVN3-L3 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Midea US3-RSJ-15/300RDVN3-L3 logs 4.0 UEF and ranks #106 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Midea US3-RSJ-15/300RDVN3-L3 holds a +1.50 UEF (+60.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Midea US3-RSJ-15/300RDVN3-L3 runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea US3-RSJ-15/300RDVN3-L3: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Midea US3-RSJ-15/300RDVN3-L3 (4.0 UEF)? Check 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity).

Which Specs Set Midea US3-RSJ-15/300RDVN3-L3 Apart From Cohort Averages?

Ranked #106 of 706 (top 19.8%) inside the 706-model Hybrid/Electric Heat Pump cohort, Midea US3-RSJ-15/300RDVN3-L3 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 3543522
Model NumberUS3-RSJ-15/300RDVN3-L3Draw pattern: High-UsageUS3-RSJ-15/300RDVN3-L3
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-04Certified 2024-11-04Markets: United States, Canada

How Do Regional kWh Prices Impact US3-RSJ-15/300RDVN3-L3 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Midea US3-RSJ-15/300RDVN3-L3's 1,240 kWh/yr draw translates to roughly $225/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,538
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $19,584
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $12,349
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,604
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $6,073
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Midea Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Midea; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
ACIQ ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80CA Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Custom Comfort CCOHPWH80A Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80US Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240

What Are the Limitations of Midea US3-RSJ-15/300RDVN3-L3 and Who Should Not Install It?

Before ordering Midea US3-RSJ-15/300RDVN3-L3 (Hybrid/Electric Heat Pump, 4.0 UEF), weigh space clearances, fuel piping, noise (49 dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Midea US3-RSJ-15/300RDVN3-L3 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea US3-RSJ-15/300RDVN3-L3 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea US3-RSJ-15/300RDVN3-L3 Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-80G-HP-WH footprint.

Frequently Asked Technical Questions: Midea US3-RSJ-15/300RDVN3-L3

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Midea US3-RSJ-15/300RDVN3-L3 pass the May 6, 2029 federal DOE efficiency rule?

Midea US3-RSJ-15/300RDVN3-L3 carries a verified 4.0 UEF rating (Pass: +1.50 / +60.0%), ranking #106 of 706 (top 19.8%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Midea US3-RSJ-15/300RDVN3-L3 need?

Midea US3-RSJ-15/300RDVN3-L3 stands 41.7 in. high with a 21.8 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Midea US3-RSJ-15/300RDVN3-L3 require?

Midea US3-RSJ-15/300RDVN3-L3 uses a 240V branch circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Midea US3-RSJ-15/300RDVN3-L3 cost per year to run?

Rated at 1,240 kWh/yr, Midea US3-RSJ-15/300RDVN3-L3 costs about $225/yr ($2,250 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).

Who should NOT install Midea US3-RSJ-15/300RDVN3-L3, and what are its limits?

Midea US3-RSJ-15/300RDVN3-L3 (4.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Midea US3-RSJ-15/300RDVN3-L3 serve at peak demand?

Midea US3-RSJ-15/300RDVN3-L3 achieves a 91 gal First Hour Rating (+19 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Midea US3-RSJ-15/300RDVN3-L3?

No active CPSC recalls matched Midea as of 2026-11-23. Always decode the serial tag on Midea US3-RSJ-15/300RDVN3-L3 because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Midea US3-RSJ-15/300RDVN3-L3, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks