Skip to main content
ENERGY STAR water heater model · PD 4682180

Midea US3-RSJ-15/300RDVN3-L4 Water Heater Specifications (4 UEF)

The Midea US3-RSJ-15/300RDVN3-L4 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First Hour Rating, ranking #106 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4682180). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.50 / +60.0%. Rated annual electricity draw of 1,230 kWh/yr equates to roughly $223/yr ($2,234 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP80 (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
75 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea US3-RSJ-15/300RDVN3-L4 at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Midea US3-RSJ-15/300RDVN3-L4: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea US3-RSJ-15/300RDVN3-L4 relative to the cohort median.
Efficiency comparison & rule summary

Midea US3-RSJ-15/300RDVN3-L4 (4.0 UEF) ranks #106 of 706 Hybrid/Electric Heat Pump models — 35-way tie; top 19.8%, more efficient than 80.2% of Hybrid/Electric Heat Pump models, +0.30 UEF above the 3.70 UEF median.

Federal 2029 margin for Midea US3-RSJ-15/300RDVN3-L4: +1.50 UEF (+60.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,230 kWh/yr for Midea US3-RSJ-15/300RDVN3-L4 runs ~$223/yr vs. ~$971/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea US3-RSJ-15/300RDVN3-L4: 10-year operating spend spans $1,799 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,803 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Midea US3-RSJ-15/300RDVN3-L4 (4.0 UEF) compares closely with Rinnai REHP80 (4.0 UEF, at parity) and Bradford White RE2HP80**-1NCTT (4.0 UEF, at parity).

How Complete Are the Certified Metrics for Midea US3-RSJ-15/300RDVN3-L4?

Standing at #106 of 706 (top 19.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Midea US3-RSJ-15/300RDVN3-L4 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 4682180
Model NumberUS3-RSJ-15/300RDVN3-L4Draw pattern: High-UsageUS3-RSJ-15/300RDVN3-L4
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,230 kWh/yr+158 kWh/yr vs. 1,072 kWh/yr medianEst. $223/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-07-31Certified 2026-07-31Markets: United States, Canada

What Is the Projected Utility Bill for US3-RSJ-15/300RDVN3-L4 by State?

At 1,230 kWh/yr, Midea US3-RSJ-15/300RDVN3-L4 averages about $223/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,230 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$223.00/yrHawaii$580.00/yrCalifornia$366.00/yrTexas$196.00/yrWashington$180.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $223/yr $2,234 $7,478
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $580/yr $5,803 $19,429
California 29.75 ¢/kWh ($0.2975) $366/yr $3,659 $12,251
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,957 $6,552
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $180/yr $1,799 $6,025
Estimated electricity spend (1,230 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Midea Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Midea in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to US3-RSJ-15/300RDVN3-L4?

Ordered by minimal capacity and UEF spread relative to Midea US3-RSJ-15/300RDVN3-L4, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rinnai REHP80 Hybrid/Electric Heat Pump 75 gal 91 gal 4.0 (at parity) 1,225
Bradford White RE2HP80**-1NCTT Hybrid/Electric Heat Pump 75 gal 88 gal 4.0 (at parity) 1,240
JETGLAS RE2HP80*-1NCTT Hybrid/Electric Heat Pump 75 gal 88 gal 4.0 (at parity) 1,240
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Rinnai REHP80BM Hybrid/Electric Heat Pump 75 gal 91 gal 4.0 (at parity) 1,225

Which Home Setups Are NOT a Fit for Midea US3-RSJ-15/300RDVN3-L4?

Comparing Midea US3-RSJ-15/300RDVN3-L4 against Rinnai REHP80 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Midea US3-RSJ-15/300RDVN3-L4 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea US3-RSJ-15/300RDVN3-L4 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea US3-RSJ-15/300RDVN3-L4 Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rinnai REHP80 footprint.

Practical Specs & Code Questions for Midea US3-RSJ-15/300RDVN3-L4

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Midea US3-RSJ-15/300RDVN3-L4 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Midea US3-RSJ-15/300RDVN3-L4 logs 4.0 UEF (Pass: +1.50 / +60.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Midea US3-RSJ-15/300RDVN3-L4?

With a 41.7 in. height and 21.8 in. diameter, Midea US3-RSJ-15/300RDVN3-L4 fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Midea US3-RSJ-15/300RDVN3-L4?

Powered via 240V at 24A max, Midea US3-RSJ-15/300RDVN3-L4 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Midea US3-RSJ-15/300RDVN3-L4?

Annual electric spend for Midea US3-RSJ-15/300RDVN3-L4 (1,230 kWh/yr) averages $223/yr nationwide (ranging from $180/yr in Washington hydro tiers up to $580/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Midea US3-RSJ-15/300RDVN3-L4?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Midea US3-RSJ-15/300RDVN3-L4.

Is Midea US3-RSJ-15/300RDVN3-L4 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Midea US3-RSJ-15/300RDVN3-L4 at 91 gal First Hour Rating (+19 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Midea have active CPSC SaferProducts notices affecting US3-RSJ-15/300RDVN3-L4?

Zero CPSC recall alerts matched Midea (2026-11-23 check). Keep your Midea US3-RSJ-15/300RDVN3-L4 serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Midea US3-RSJ-15/300RDVN3-L4 (4.0 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Midea US3-RSJ-15/300RDVN3-L4. Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP80 (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks