RELIANCE WATER HEATERS 10-80-DHPTS 2** Water Heater Specifications (3.88 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, RELIANCE WATER HEATERS 10-80-DHPTS 2** (Electric) achieves a certified 3.88 UEF rating across its 82-gallon nominal tank, 95 gal First Hour Rating (rank #165 of 706, PD 2408834) and verifies as Pass: +1.38 / +55.2% for 2029 DOE floors. Rated annual electricity draw of 1,279 kWh/yr equates to roughly $232/yr ($2,323 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).
- Uniform Energy Factor
- 3.88 UEF
- Cohort UEF Rank
- #165 of 706 (top 30.6%)
- First Hour Rating
- 95 gal
- Storage Volume
- 82 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.38 / +55.2%

RELIANCE WATER HEATERS 10-80-DHPTS 2** records 3.88 UEF efficiency, putting it #165 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: RELIANCE WATER HEATERS 10-80-DHPTS 2** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.38 UEF (+55.2%). At EIA August 2026 national rates (18.16 cents/kWh), 1,279 kWh/yr for RELIANCE WATER HEATERS 10-80-DHPTS 2** runs ~$232/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for RELIANCE WATER HEATERS 10-80-DHPTS 2**: 10-year operating spend spans $1,871 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside RELIANCE WATER HEATERS 10-80-DHPTS 2** (3.88 UEF) are A. O. Smith HPS10-80H45DV 2** (3.88 UEF, at parity) and American HPS10280H045DV 2** (3.88 UEF, at parity).
How Do RELIANCE WATER HEATERS 10-80-DHPTS 2** Specs Compare to Hybrid/Electric Heat Pump Medians?
RELIANCE WATER HEATERS 10-80-DHPTS 2** places #165 of 706 (top 30.6%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | RELIANCE WATER HEATERS | 71 certified listings | ENERGY STAR PD 2408834 |
| Model Number | 10-80-DHPTS 2** | Draw pattern: High-Usage | 10-80-DHPTS 2** |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 95 gal | +23 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,279 kWh/yr | +207 kWh/yr vs. 1,072 kWh/yr median | Est. $232/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
What Does 10-80-DHPTS 2** Cost to Operate Across State Electricity Rates?
At 1,279 kWh/yr, RELIANCE WATER HEATERS 10-80-DHPTS 2** runs roughly $232/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $232/yr | $2,323 | $7,473 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $603/yr | $6,034 | $19,415 |
| California | 29.75 ¢/kWh ($0.2975) | $381/yr | $3,805 | $12,242 |
| Texas | 15.91 ¢/kWh ($0.1591) | $203/yr | $2,035 | $6,547 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $187/yr | $1,871 | $6,020 |
Are There Active CPSC Safety Recalls for RELIANCE WATER HEATERS Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 3 brand-level recall notices associated with RELIANCE WATER HEATERS; match your serial plate before repair. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
Which Certified Water Heaters Match 10-80-DHPTS 2** Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to RELIANCE WATER HEATERS 10-80-DHPTS 2** by storage capacity and 3.88 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPS10-80H45DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
| American HPS10280H045DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
| Lochinvar HPSA080KD 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
| State HPSX-80-DHPT 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
| A. O. Smith HPSN10-80H45DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
What Are the Limitations of RELIANCE WATER HEATERS 10-80-DHPTS 2** and Who Should Not Install It?
Before ordering RELIANCE WATER HEATERS 10-80-DHPTS 2** (Hybrid/Electric Heat Pump, 3.88 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- RELIANCE WATER HEATERS 10-80-DHPTS 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 10-80-DHPTS 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About RELIANCE WATER HEATERS 10-80-DHPTS 2**?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does RELIANCE WATER HEATERS 10-80-DHPTS 2** pass the May 6, 2029 federal DOE efficiency rule?
RELIANCE WATER HEATERS 10-80-DHPTS 2** carries a verified 3.88 UEF rating (Pass: +1.38 / +55.2%), ranking #165 of 706 (top 30.6%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does RELIANCE WATER HEATERS 10-80-DHPTS 2** need?
RELIANCE WATER HEATERS 10-80-DHPTS 2** stands 69 in. high with a 27 in. diameter; verify 72 in. vertical headroom; tight at 28 in. door (27" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does RELIANCE WATER HEATERS 10-80-DHPTS 2** require?
RELIANCE WATER HEATERS 10-80-DHPTS 2** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does RELIANCE WATER HEATERS 10-80-DHPTS 2** cost per year to run?
Rated at 1,279 kWh/yr, RELIANCE WATER HEATERS 10-80-DHPTS 2** costs about $232/yr ($2,320 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $187/yr in Washington hydro tiers up to $603/yr in Hawaii).
Who should NOT install RELIANCE WATER HEATERS 10-80-DHPTS 2**, and what are its limits?
RELIANCE WATER HEATERS 10-80-DHPTS 2** (3.88 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can RELIANCE WATER HEATERS 10-80-DHPTS 2** serve at peak demand?
RELIANCE WATER HEATERS 10-80-DHPTS 2** achieves a 95 gal First Hour Rating (+23 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for RELIANCE WATER HEATERS 10-80-DHPTS 2**?
CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to RELIANCE WATER HEATERS 10-80-DHPTS 2**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)