The A. O. Smith HPS10-80H45DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.88 UEF rating across its 82-gallon nominal tank, 95 gal First Hour Rating, ranking #165 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408840). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.38 / +55.2%. Rated annual electricity draw of 1,279 kWh/yr equates to roughly $232/yr ($2,323 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPS10280H045DV 2** (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
95 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.38 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPS10-80H45DV 2** at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPS10-80H45DV 2**: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPS10-80H45DV 2** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPS10-80H45DV 2** (3.88 UEF) ranks #165 of 706 Hybrid/Electric Heat Pump models — 52-way tie; top 30.6%, more efficient than 69.4% of Hybrid/Electric Heat Pump models, +0.18 UEF above the 3.70 UEF median.

Federal 2029 margin for A. O. Smith HPS10-80H45DV 2**: +1.38 UEF (+55.2%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,279 kWh/yr for A. O. Smith HPS10-80H45DV 2** runs ~$232/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPS10-80H45DV 2**: 10-year operating spend spans $1,871 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: A. O. Smith HPS10-80H45DV 2** (3.88 UEF) compares closely with American HPS10280H045DV 2** (3.88 UEF, at parity) and Lochinvar HPSA080KD 2** (3.88 UEF, at parity).

How Do A. O. Smith HPS10-80H45DV 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

A. O. Smith HPS10-80H45DV 2** places #165 of 706 (top 30.6%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2408840
Model NumberHPS10-80H45DV 2**Draw pattern: High-UsageHPS10-80H45DV 2**
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,279 kWh/yr+207 kWh/yr vs. 1,072 kWh/yr medianEst. $232/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

What Does HPS10-80H45DV 2** Cost to Operate Across State Electricity Rates?

At 1,279 kWh/yr, A. O. Smith HPS10-80H45DV 2** runs roughly $232/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,279 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$232.00/yrHawaii$603.00/yrCalifornia$381.00/yrTexas$203.00/yrWashington$187.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $232/yr $2,323 $7,473
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $603/yr $6,034 $19,415
California 29.75 ¢/kWh ($0.2975) $381/yr $3,805 $12,242
Texas 15.91 ¢/kWh ($0.1591) $203/yr $2,035 $6,547
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $187/yr $1,871 $6,020
Estimated electricity spend (1,279 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match HPS10-80H45DV 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith HPS10-80H45DV 2** by storage capacity and 3.88 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPS10280H045DV 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (at parity) 1,279
Lochinvar HPSA080KD 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (at parity) 1,279
RELIANCE WATER HEATERS 10-80-DHPTS 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (at parity) 1,279
State HPSX-80-DHPT 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (at parity) 1,279
American HPHE10280H045DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (-0.43) 1,387

When Should Homeowners Skip A. O. Smith HPS10-80H45DV 2** (Hybrid/Electric Heat Pump)?

Check A. O. Smith HPS10-80H45DV 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.38 / +55.2% status—against typical residential installations.

Key Limitations & Exclusions

  • A. O. Smith HPS10-80H45DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPS10-80H45DV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPS10-80H45DV 2** Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPS10280H045DV 2** footprint.

What Are the Key Questions About A. O. Smith HPS10-80H45DV 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will A. O. Smith HPS10-80H45DV 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.88 UEF, A. O. Smith HPS10-80H45DV 2** shows Pass: +1.38 / +55.2% relative to May 6, 2029 federal DOE limits while placing #165 of 706 (top 30.6%) among 706 Hybrid/Electric Heat Pump peers like American HPS10280H045DV 2**.

Will A. O. Smith HPS10-80H45DV 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 69 in. tall by 27 in. diameter, A. O. Smith HPS10-80H45DV 2** notes: verify 72 in. vertical headroom; tight at 28 in. door (27" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support A. O. Smith HPS10-80H45DV 2** during replacement?

Electrical specs for A. O. Smith HPS10-80H45DV 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for A. O. Smith HPS10-80H45DV 2**?

At 18.16 cents/kWh national residential pricing, A. O. Smith HPS10-80H45DV 2**'s 1,279 kWh/yr draw equals roughly $232 annually or $2,320 across a 10-year horizon (ranging from $187/yr in Washington hydro tiers up to $603/yr in Hawaii).

When is A. O. Smith HPS10-80H45DV 2** a poor fit for a residential replacement?

Avoid placing A. O. Smith HPS10-80H45DV 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does A. O. Smith HPS10-80H45DV 2** deliver?

With 95 gal FHR (+23 gal vs. 72 gal median), A. O. Smith HPS10-80H45DV 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on A. O. Smith HPS10-80H45DV 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does A. O. Smith HPS10-80H45DV 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith HPS10-80H45DV 2**. Closest peer in Hybrid/Electric Heat Pump is American HPS10280H045DV 2** (3.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks