RELIANCE WATER HEATERS 8-75-*TPDT 4** Water Heater Specifications (0.86 UEF)
Certified at 0.86 UEF across its 74-gallon nominal tank, 150 gal First Hour Rating, RELIANCE WATER HEATERS 8-75-*TPDT 4** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) places #62 of 71 out of 71 ENERGY STAR models (PD 4518081). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.28 / +48.3%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Closest certified alternative is A. O. Smith HDHE-75 4** (0.86 UEF).
- Uniform Energy Factor
- 0.86 UEF
- Cohort UEF Rank
- #62 of 71
- First Hour Rating
- 150 gal
- Storage Volume
- 74 gal
- Fuel / Type
- Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
- DOE 2029 Rule Status
- Pass: +0.28 / +48.3%

Tested at 0.86 UEF, RELIANCE WATER HEATERS 8-75-*TPDT 4** places #62 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations (-0.02 UEF vs. 0.88 UEF median).
Reliance water heaters 8-75-*tpdt 4** stores 74 gal nominal; 150 gal first hour rating (+14 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d).
Closest alternatives to RELIANCE WATER HEATERS 8-75-*TPDT 4** include A. O. Smith HDHE-75 4** (0.86 UEF, at parity) alongside American VG8275T100*V (0.86 UEF, at parity).
Where Does RELIANCE WATER HEATERS 8-75-*TPDT 4** Rank Against Peer Gas-fired Storage Residential-duty Commercial Units?
Audited against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial listings, RELIANCE WATER HEATERS 8-75-*TPDT 4** holds #62 of 71; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | RELIANCE WATER HEATERS | 71 certified listings | ENERGY STAR PD 4518081 |
| Model Number | 8-75-*TPDT 4** | Draw pattern: High-Usage | 8-75-*TPDT 4** |
| Uniform Energy Factor (UEF) | 0.86 | -0.02 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 150 gal | +14 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +2.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 51.9" H x 22.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
Does CPSC Flag Any Safety Notices on RELIANCE WATER HEATERS Units?
Checking 2026-11-23 SaferProducts data shows 3 notices mentioning RELIANCE WATER HEATERS; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
Which Competing Gas-fired Storage Residential-duty Commercial Models Compare Closest to 8-75-*TPDT 4**?
Compare five nearby ENERGY STAR Gas-fired Storage Residential-duty Commercial options matched closely to RELIANCE WATER HEATERS 8-75-*TPDT 4**'s gallon capacity and 0.86 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HDHE-75 4** | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| American VG8275T100*V | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| GSW WATER HEATERS 8G-75100*PDV-H06* 4** | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| State GP-8-75-*TPDT 4** | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| A. O. Smith GDHE-75 3** | Gas-fired Storage Residential-duty Commercial | 74 gal | 130 gal | 0.86 (at parity) | — |
What Are the Limitations of RELIANCE WATER HEATERS 8-75-*TPDT 4** and Who Should Not Install It?
Before ordering RELIANCE WATER HEATERS 8-75-*TPDT 4** (Gas-fired Storage Residential-duty Commercial, 0.86 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- RELIANCE WATER HEATERS 8-75-*TPDT 4** logs 0.86 UEF (Pass: +0.28 / +48.3%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect RELIANCE WATER HEATERS 8-75-*TPDT 4**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 150 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Common Homeowner Questions for RELIANCE WATER HEATERS 8-75-*TPDT 4**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does RELIANCE WATER HEATERS 8-75-*TPDT 4** pass the May 6, 2029 federal DOE efficiency rule?
RELIANCE WATER HEATERS 8-75-*TPDT 4** carries a verified 0.86 UEF rating (Pass: +0.28 / +48.3%), ranking #62 of 71 across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.
What doorway width and ceiling height does RELIANCE WATER HEATERS 8-75-*TPDT 4** need?
RELIANCE WATER HEATERS 8-75-*TPDT 4** stands 51.9 in. high with a 22.5 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does RELIANCE WATER HEATERS 8-75-*TPDT 4** require?
RELIANCE WATER HEATERS 8-75-*TPDT 4** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.
How much electricity or energy does RELIANCE WATER HEATERS 8-75-*TPDT 4** cost per year to run?
ENERGY STAR rates RELIANCE WATER HEATERS 8-75-*TPDT 4** as a Natural Gas, Propane heater (0.86 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.
Who should NOT install RELIANCE WATER HEATERS 8-75-*TPDT 4**, and what are its limits?
RELIANCE WATER HEATERS 8-75-*TPDT 4** (0.86 UEF) is not suited for multi-bath marathon draws exceeding its 150 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.
How many bathrooms or people can RELIANCE WATER HEATERS 8-75-*TPDT 4** serve at peak demand?
RELIANCE WATER HEATERS 8-75-*TPDT 4** achieves a 150 gal First Hour Rating (+14 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for RELIANCE WATER HEATERS 8-75-*TPDT 4**?
CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to RELIANCE WATER HEATERS 8-75-*TPDT 4**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith HDHE-75 4** (0.86 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)