State GP-8-75-*TPDT 4** Water Heater Specifications (0.86 UEF)
Certified at 0.86 UEF across its 74-gallon nominal tank, 150 gal First Hour Rating, State GP-8-75-*TPDT 4** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) places #62 of 71 out of 71 ENERGY STAR models (PD 4518076). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.28 / +48.3%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Closest certified alternative is A. O. Smith HDHE-75 4** (0.86 UEF).
- Uniform Energy Factor
- 0.86 UEF
- Cohort UEF Rank
- #62 of 71
- First Hour Rating
- 150 gal
- Storage Volume
- 74 gal
- Fuel / Type
- Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
- DOE 2029 Rule Status
- Pass: +0.28 / +48.3%

Tested at 0.86 UEF, State GP-8-75-*TPDT 4** places #62 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations (-0.02 UEF vs. 0.88 UEF median).
State gp-8-75-*tpdt 4** stores 74 gal nominal; 150 gal first hour rating (+14 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d).
Closest alternatives to State GP-8-75-*TPDT 4** include A. O. Smith HDHE-75 4** (0.86 UEF, at parity) alongside American VG8275T100*V (0.86 UEF, at parity).
Which Specs Set State GP-8-75-*TPDT 4** Apart From Cohort Averages?
Ranked #62 of 71 inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, State GP-8-75-*TPDT 4** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | State | 81 certified listings | ENERGY STAR PD 4518076 |
| Model Number | GP-8-75-*TPDT 4** | Draw pattern: High-Usage | GP-8-75-*TPDT 4** |
| Uniform Energy Factor (UEF) | 0.86 | -0.02 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 150 gal | +14 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +2.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 51.9" H x 22.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
What Should State Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to State; verify whether your GP-8-75-*TPDT 4** production run falls inside affected ranges. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?
Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HDHE-75 4** | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| American VG8275T100*V | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| GSW WATER HEATERS 8G-75100*PDV-H06* 4** | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| RELIANCE WATER HEATERS 8-75-*TPDT 4** | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| A. O. Smith GDHE-75 3** | Gas-fired Storage Residential-duty Commercial | 74 gal | 130 gal | 0.86 (at parity) | — |
What Are the Limitations of State GP-8-75-*TPDT 4** and Who Should Not Install It?
Before ordering State GP-8-75-*TPDT 4** (Gas-fired Storage Residential-duty Commercial, 0.86 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- State GP-8-75-*TPDT 4** logs 0.86 UEF (Pass: +0.28 / +48.3%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect State GP-8-75-*TPDT 4**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 150 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: State GP-8-75-*TPDT 4**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does State GP-8-75-*TPDT 4** pass the May 6, 2029 federal DOE efficiency rule?
State GP-8-75-*TPDT 4** carries a verified 0.86 UEF rating (Pass: +0.28 / +48.3%), ranking #62 of 71 across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.
What doorway width and ceiling height does State GP-8-75-*TPDT 4** need?
State GP-8-75-*TPDT 4** stands 51.9 in. high with a 22.5 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does State GP-8-75-*TPDT 4** require?
State GP-8-75-*TPDT 4** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.
How much electricity or energy does State GP-8-75-*TPDT 4** cost per year to run?
ENERGY STAR rates State GP-8-75-*TPDT 4** as a Natural Gas, Propane heater (0.86 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.
Who should NOT install State GP-8-75-*TPDT 4**, and what are its limits?
State GP-8-75-*TPDT 4** (0.86 UEF) is not suited for multi-bath marathon draws exceeding its 150 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.
How many bathrooms or people can State GP-8-75-*TPDT 4** serve at peak demand?
State GP-8-75-*TPDT 4** achieves a 150 gal First Hour Rating (+14 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for State GP-8-75-*TPDT 4**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to State GP-8-75-*TPDT 4**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith HDHE-75 4** (0.86 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)