RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** Water Heater Specifications (3.55 UEF)
With PD 4529468 certification, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.55 UEF rating across its 48-gallon nominal tank, 72 gal First Hour Rating, standing #414 of 706 across 706 peers with Pass: +1.25 / +54.3% for May 6, 2029. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).
- Uniform Energy Factor
- 3.55 UEF
- Cohort UEF Rank
- #414 of 706
- First Hour Rating
- 72 gal
- Storage Volume
- 48 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.25 / +54.3%

ENERGY STAR certification places RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** at 3.55 UEF (#414 of 706; -0.15 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** stands +1.25 UEF (+54.3%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** runs ~$166/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1**: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF, at parity) and American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF, at parity) bracket RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1**.
How Complete Are the Certified Metrics for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1**?
Standing at #414 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | RELIANCE WATER HEATERS | 71 certified listings | ENERGY STAR PD 4529468 |
| Model Number | RHPCO-45 1**+RXST-50LBG 1** | Draw pattern: Medium-Usage | RHPCO-45 1**+RXST-50LBG 1** |
| Uniform Energy Factor (UEF) | 3.55 | -0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 72 gal | At 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 915 kWh/yr | -157 kWh/yr vs. 1,072 kWh/yr median | Est. $166/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 428% | -1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 33" H x 22.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |
What Is the Projected Utility Bill for RHPCO-45 1**+RXST-50LBG 1** by State?
At 915 kWh/yr, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** averages about $166/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $166/yr | $1,662 | $4,751 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $432/yr | $4,317 | $12,342 |
| California | 29.75 ¢/kWh ($0.2975) | $272/yr | $2,722 | $7,783 |
| Texas | 15.91 ¢/kWh ($0.1591) | $146/yr | $1,456 | $4,162 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $134/yr | $1,339 | $3,827 |
Are RELIANCE WATER HEATERS Models Affected by Current CPSC Notices?
Review 3 brand-matched CPSC entries pulled 2026-11-23 for RELIANCE WATER HEATERS and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
Which 5 Models Offer Similar Output to RHPCO-45 1**+RXST-50LBG 1**?
Ordered by minimal capacity and UEF spread relative to RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1**, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
| American MHPCO-45 1**+MXST-50LBTTP 1** | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
| Giant GTHPCO-45 1**+GTXST-50LBTTP 1* | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-50LBTTP 1** | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
| A. O. Smith HPACO-45C 1**+AXST-50LBCTTP 1* | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
What Are the Limitations of RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** and Who Should Not Install It?
Before ordering RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** (Hybrid/Electric Heat Pump, 3.55 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** pass the May 6, 2029 federal DOE efficiency rule?
RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** carries a verified 3.55 UEF rating (Pass: +1.25 / +54.3%), ranking #414 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** need?
RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** stands 33 in. high with a 22.5 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** require?
RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** cost per year to run?
Rated at 915 kWh/yr, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** costs about $166/yr ($1,660 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii).
Who should NOT install RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1**, and what are its limits?
RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** (3.55 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** serve at peak demand?
RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1** achieves a 72 gal First Hour Rating (At 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1**?
CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50LBG 1**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)