ENERGY STAR water heater model · PD 4529442

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** achieves a certified 3.7 UEF rating across its 60-gallon nominal tank, 82 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 4529442), recording Pass: +1.20 / +48.0% under 2029 DOE rules. Rated annual electricity draw of 1,341 kWh/yr equates to roughly $244/yr ($2,435 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
82 gal
Storage Volume
60 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1**: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** holds a +1.20 UEF (+48.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,341 kWh/yr for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** runs ~$244/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1**: 10-year operating spend spans $1,962 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,327 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** (3.7 UEF)? Check A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF, at parity) and American MHPCO-45 1**+MXST-66 1** (3.7 UEF, at parity).

How Do RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** places #347 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 4529442
Model NumberRHPCO-45 1**+RXST-66G 1**Draw pattern: High-UsageRHPCO-45 1**+RXST-66G 1**
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,341 kWh/yr+269 kWh/yr vs. 1,072 kWh/yr medianEst. $244/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)59" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

What Does RHPCO-45 1**+RXST-66G 1** Cost to Operate Across State Electricity Rates?

At 1,341 kWh/yr, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** runs roughly $244/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,341 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$244.00/yrHawaii$633.00/yrCalifornia$399.00/yrTexas$213.00/yrWashington$196.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $244/yr $2,435 $7,358
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $633/yr $6,327 $19,117
California 29.75 ¢/kWh ($0.2975) $399/yr $3,989 $12,055
Texas 15.91 ¢/kWh ($0.1591) $213/yr $2,134 $6,447
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $196/yr $1,962 $5,928
Estimated electricity spend (1,341 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for RELIANCE WATER HEATERS Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 3 brand-level recall notices associated with RELIANCE WATER HEATERS; match your serial plate before repair. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Certified Water Heaters Match RHPCO-45 1**+RXST-66G 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** by storage capacity and 3.7 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
American MHPCO-45 1**+MXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
Giant GTHPCO-45 1**+GTXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
GSW WATER HEATERS GHPCO-45 1**+GXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
A. O. Smith HPACO-45 1**+AXST-66TTP 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341

What Installation Caveats Apply Before Buying RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1**?

Even high-UEF units like RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** (3.7 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-66 1** footprint.

What Are the Key Questions About RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** eligible for continued manufacture past May 6, 2029?

At 3.7 UEF, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** achieves Pass: +1.20 / +48.0% for the 2029 DOE standard and stands #347 of 706 against A. O. Smith HPACO-45 1**+AXST-66 1** and American MHPCO-45 1**+MXST-66 1**.

How tall and wide is RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1**, and what service clearance is needed?

Physical dimensions for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** are 59 in. height and 18 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d)); verify stair turns and drain pan width before delivery.

Will RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** require upgrading household electrical panels or gas piping?

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** draws 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $244/yr ($2,440 over 10 years) to power RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** at 1,341 kWh/yr under the 18.16 cents/kWh US average (ranging from $196/yr in Washington hydro tiers up to $633/yr in Hawaii).

Which installation bottlenecks limit RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** drops into resistance mode more often.

How does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** handle simultaneous showers and laundry?

Delivering 82 gal in the first hour (+10 gal vs. 72 gal median), RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** combines 60 gal tank storage with rapid burner/element recovery.

How long is the warranty on RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1** and how do you decode its serial?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66G 1**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks