Rheem CXE40T10H45U1 Water Heater Specifications (3.83 UEF)
The Rheem CXE40T10H45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, ranking #230 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3554185). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.53 / +66.5%. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).
- Uniform Energy Factor
- 3.83 UEF
- Cohort UEF Rank
- #230 of 706 (top 37.8%)
- First Hour Rating
- 60 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.53 / +66.5%

Rheem CXE40T10H45U1 (3.83 UEF) ranks #230 of 706 Hybrid/Electric Heat Pump models — 38-way tie; top 37.8%, more efficient than 62.2% of Hybrid/Electric Heat Pump models, +0.13 UEF above the 3.70 UEF median.
Federal 2029 margin for Rheem CXE40T10H45U1: +1.53 UEF (+66.5%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Rheem CXE40T10H45U1 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem CXE40T10H45U1: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Rheem CXE40T10H45U1 (3.83 UEF) compares closely with Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) and Richmond 10CE40-HP5U30 (3.83 UEF, at parity).
What Physical and Thermal Ratings Define Rheem CXE40T10H45U1?
Positioning at #230 of 706 (top 37.8%) out of 706 Hybrid/Electric Heat Pump peers, Rheem CXE40T10H45U1 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554185 |
| Model Number | CXE40T10H45U1 | Draw pattern: Medium-Usage | CXE40T10H45U1 |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 859 kWh/yr | -213 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 434% | +5.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
Why Do State Utility Rates Shift CXE40T10H45U1 Running Costs?
Consuming 859 kWh annually puts Rheem CXE40T10H45U1 near $156/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,560 | $4,934 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $405/yr | $4,053 | $12,819 |
| California | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,556 | $8,083 |
| Texas | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,367 | $4,323 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,257 | $3,975 |
Have Any Rheem Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to Rheem CXE40T10H45U1?
Homeowners cross-shopping Rheem CXE40T10H45U1 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T2 FD400-30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| Richmond 10CE40-HP5U30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| Ruud CPROPH40 T2 CD375-30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (-0.23) | 902 |
| Friedrich PROH40 T2 FD400-SO | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
When Should Homeowners Skip Rheem CXE40T10H45U1 (Hybrid/Electric Heat Pump)?
Check Rheem CXE40T10H45U1's mechanical constraints—including utility space, Electric capacity, and Pass: +1.53 / +66.5% status—against typical residential installations.
Key Limitations & Exclusions
- Rheem CXE40T10H45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CXE40T10H45U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Rheem CXE40T10H45U1
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Rheem CXE40T10H45U1 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.83 UEF, Rheem CXE40T10H45U1 shows Pass: +1.53 / +66.5% relative to May 6, 2029 federal DOE limits while placing #230 of 706 (top 37.8%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH40 T2 FD400-30.
Will Rheem CXE40T10H45U1 fit through a standard utility door and 72-inch basement ceiling?
Measuring 62.3 in. tall by 20.3 in. diameter, Rheem CXE40T10H45U1 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Rheem CXE40T10H45U1 during replacement?
Electrical specs for Rheem CXE40T10H45U1 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Rheem CXE40T10H45U1?
At 18.16 cents/kWh national residential pricing, Rheem CXE40T10H45U1's 859 kWh/yr draw equals roughly $156 annually or $1,560 across a 10-year horizon (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii).
When is Rheem CXE40T10H45U1 a poor fit for a residential replacement?
Avoid placing Rheem CXE40T10H45U1 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Rheem CXE40T10H45U1 deliver?
With 60 gal FHR (-12 gal vs. 72 gal median), Rheem CXE40T10H45U1 fits 1–3 person or moderate-draw homes cleanly.
How do you verify manufacturing age and recall status on Rheem CXE40T10H45U1?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does Rheem CXE40T10H45U1 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rheem CXE40T10H45U1. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)