Rheem PRO H80 T2 RH310BM Water Heater Specifications (3.5 UEF)
The Rheem PRO H80 T2 RH310BM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating, ranking #481 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408525). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.00 / +40.0%. Rated annual electricity draw of 1,303 kWh/yr equates to roughly $237/yr ($2,366 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD310BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 87 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.00 / +40.0%

Rheem PRO H80 T2 RH310BM (3.5 UEF) ranks #481 of 706 Hybrid/Electric Heat Pump models — 64-way tie; more efficient than 22.9% of Hybrid/Electric Heat Pump models, -0.20 UEF below the 3.70 UEF median.
Federal 2029 margin for Rheem PRO H80 T2 RH310BM: +1.00 UEF (+40.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,303 kWh/yr for Rheem PRO H80 T2 RH310BM runs ~$237/yr vs. ~$900/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem PRO H80 T2 RH310BM: 10-year operating spend spans $1,906 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,148 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Rheem PRO H80 T2 RH310BM (3.5 UEF) compares closely with Friedrich PROH80 T2 FD310BM (3.5 UEF, at parity) and Ruud PRO H80 T2 RU310BM (3.5 UEF, at parity).
What Physical and Thermal Ratings Define Rheem PRO H80 T2 RH310BM?
Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, Rheem PRO H80 T2 RH310BM pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 2408525 |
| Model Number | PRO H80 T2 RH310BM | Draw pattern: High-Usage | PRO H80 T2 RH310BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,303 kWh/yr | +231 kWh/yr vs. 1,072 kWh/yr median | Est. $237/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 398% | -31.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
Why Do State Utility Rates Shift PRO H80 T2 RH310BM Running Costs?
Consuming 1,303 kWh annually puts Rheem PRO H80 T2 RH310BM near $237/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $237/yr | $2,366 | $6,636 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $615/yr | $6,148 | $17,240 |
| California | 29.75 ¢/kWh ($0.2975) | $388/yr | $3,876 | $10,871 |
| Texas | 15.91 ¢/kWh ($0.1591) | $207/yr | $2,073 | $5,814 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $191/yr | $1,906 | $5,346 |
Have Any Rheem Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to Rheem PRO H80 T2 RH310BM?
Homeowners cross-shopping Rheem PRO H80 T2 RH310BM frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T2 FD310BM | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |
| Ruud PRO H80 T2 RU310BM | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |
| Richmond 10E80-HP120M | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (-0.04) | 1,403 |
| LG APHWC801D | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.40) | 1,272 |
| Friedrich PROH80 T2 FD310UM | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |
When Should Homeowners Skip Rheem PRO H80 T2 RH310BM (Hybrid/Electric Heat Pump)?
Check Rheem PRO H80 T2 RH310BM's mechanical constraints—including utility space, Electric capacity, and Pass: +1.00 / +40.0% status—against typical residential installations.
Key Limitations & Exclusions
- Rheem PRO H80 T2 RH310BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem PRO H80 T2 RH310BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Rheem PRO H80 T2 RH310BM
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Rheem PRO H80 T2 RH310BM stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.5 UEF, Rheem PRO H80 T2 RH310BM shows Pass: +1.00 / +40.0% relative to May 6, 2029 federal DOE limits while placing #481 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH80 T2 FD310BM.
Will Rheem PRO H80 T2 RH310BM fit through a standard utility door and 72-inch basement ceiling?
Measuring 74.2 in. tall by 24.3 in. diameter, Rheem PRO H80 T2 RH310BM notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Rheem PRO H80 T2 RH310BM during replacement?
Electrical specs for Rheem PRO H80 T2 RH310BM call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Rheem PRO H80 T2 RH310BM?
At 18.16 cents/kWh national residential pricing, Rheem PRO H80 T2 RH310BM's 1,303 kWh/yr draw equals roughly $237 annually or $2,370 across a 10-year horizon (ranging from $191/yr in Washington hydro tiers up to $615/yr in Hawaii).
When is Rheem PRO H80 T2 RH310BM a poor fit for a residential replacement?
Avoid placing Rheem PRO H80 T2 RH310BM directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Rheem PRO H80 T2 RH310BM deliver?
With 87 gal FHR (+15 gal vs. 72 gal median), Rheem PRO H80 T2 RH310BM fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Rheem PRO H80 T2 RH310BM?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does Rheem PRO H80 T2 RH310BM qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rheem PRO H80 T2 RH310BM. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD310BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)