Rheem PROP G50-76* CN HE EC3 Water Heater Specifications (0.89 UEF)

The Rheem PROP G50-76* CN HE EC3 (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.89 UEF rating across its 50-gallon nominal tank, 136 gal First Hour Rating, ranking #8 of 71 among 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models (PD 2408630). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.31 / +53.4%. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 50-76P FD HE EC3 (0.89 UEF).

Uniform Energy Factor
0.89 UEF
Cohort UEF Rank
#8 of 71
First Hour Rating
136 gal
Storage Volume
50 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.31 / +53.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking Rheem PROP G50-76* CN HE EC3 at 0.89 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58Rheem PROP G50-76* CN HE EC3: 0.89
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Rheem PROP G50-76* CN HE EC3 relative to the cohort median.
Efficiency comparison & rule summary

Rheem PROP G50-76* CN HE EC3 (0.89 UEF) ranks #8 of 71 Gas-fired Storage Residential-duty Commercial models — 26-way tie; more efficient than 53.5% of Gas-fired Storage Residential-duty Commercial models, +0.01 UEF above the 0.88 UEF median.

Rheem prop g50-76* cn he ec3 stores 50 gal nominal; 136 gal first hour rating (at 136 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d).

Peer comparison: Rheem PROP G50-76* CN HE EC3 (0.89 UEF) compares closely with Friedrich 12PROG 50-76P FD HE EC3 (0.89 UEF, at parity) and Richmond 12GUH50-76F* (0.89 UEF, at parity).

How Do Rheem PROP G50-76* CN HE EC3 Specs Compare to Gas-fired Storage Residential-duty Commercial Medians?

Rheem PROP G50-76* CN HE EC3 places #8 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 2408630
Model NumberPROP G50-76* CN HE EC3Draw pattern: High-UsagePROP G50-76* CN HE EC3
Uniform Energy Factor (UEF)0.89+0.01 UEF vs. 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)136 galAt 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency95%At 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)65.5" H x 21.8" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-04Certified 2024-11-04Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Rheem Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match PROP G50-76* CN HE EC3 Most Closely?

These 5 competing Gas-fired Storage Residential-duty Commercial units sit nearest to Rheem PROP G50-76* CN HE EC3 by storage capacity and 0.89 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 50-76P FD HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 136 gal 0.89 (at parity) —
Richmond 12GUH50-76F* Gas-fired Storage Residential-duty Commercial 50 gal 136 gal 0.89 (at parity) —
Ruud PROU G50-76* RU HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 136 gal 0.89 (at parity) —
A. O. Smith HDHE-50 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (-0.01) —
Friedrich 12PROG 50-76U FD HE EC3 Gas-fired Storage Residential-duty Commercial 50 gal 136 gal 0.89 (at parity) —

What Are the Limitations of Rheem PROP G50-76* CN HE EC3 and Who Should Not Install It?

Before ordering Rheem PROP G50-76* CN HE EC3 (Gas-fired Storage Residential-duty Commercial, 0.89 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Rheem PROP G50-76* CN HE EC3 logs 0.89 UEF (Pass: +0.31 / +53.4%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Rheem PROP G50-76* CN HE EC3's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 136 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Rheem PROP G50-76* CN HE EC3 Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 50-76P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

What Are the Key Questions About Rheem PROP G50-76* CN HE EC3?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Rheem PROP G50-76* CN HE EC3 pass the May 6, 2029 federal DOE efficiency rule?

Rheem PROP G50-76* CN HE EC3 carries a verified 0.89 UEF rating (Pass: +0.31 / +53.4%), ranking #8 of 71 across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.

What doorway width and ceiling height does Rheem PROP G50-76* CN HE EC3 need?

Rheem PROP G50-76* CN HE EC3 stands 65.5 in. high with a 21.8 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Rheem PROP G50-76* CN HE EC3 require?

Rheem PROP G50-76* CN HE EC3 runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does Rheem PROP G50-76* CN HE EC3 cost per year to run?

ENERGY STAR rates Rheem PROP G50-76* CN HE EC3 as a Natural Gas, Propane heater (0.89 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.

Who should NOT install Rheem PROP G50-76* CN HE EC3, and what are its limits?

Rheem PROP G50-76* CN HE EC3 (0.89 UEF) is not suited for multi-bath marathon draws exceeding its 136 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

How many bathrooms or people can Rheem PROP G50-76* CN HE EC3 serve at peak demand?

Rheem PROP G50-76* CN HE EC3 achieves a 136 gal First Hour Rating (At 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Rheem PROP G50-76* CN HE EC3?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to Rheem PROP G50-76* CN HE EC3, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 50-76P FD HE EC3 (0.89 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)