Skip to main content
ENERGY STAR water heater model · PD 4518078

A. O. Smith HDHE-50 4** Water Heater Specifications (0.88 UEF)

With PD 4518078 certification, A. O. Smith HDHE-50 4** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.88 UEF rating across its 49-gallon nominal tank, 118 gal First Hour Rating, standing #34 of 71 across 71 peers with Pass: +0.30 / +51.7% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Closest certified alternative is American VG8250T100*V (0.88 UEF).

Uniform Energy Factor
0.88 UEF
Cohort UEF Rank
#34 of 71
First Hour Rating
118 gal
Storage Volume
49 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.30 / +51.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking A. O. Smith HDHE-50 4** at 0.88 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58A. O. Smith HDHE-50 4**: 0.88
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows A. O. Smith HDHE-50 4** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places A. O. Smith HDHE-50 4** at 0.88 UEF (#34 of 71; At 0.88 UEF median) in Gas-fired Storage Residential-duty Commercial.

A. o. smith hdhe-50 4** stores 49 gal nominal; 118 gal first hour rating (-18 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d).

In the Gas-fired Storage Residential-duty Commercial tier, American VG8250T100*V (0.88 UEF, at parity) and GSW WATER HEATERS 8G-50100*PDV-H06* 4** (0.88 UEF, at parity) bracket A. O. Smith HDHE-50 4**.

Which Specs Set A. O. Smith HDHE-50 4** Apart From Cohort Averages?

Ranked #34 of 71 inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, A. O. Smith HDHE-50 4** is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4518078
Model NumberHDHE-50 4**Draw pattern: High-UsageHDHE-50 4**
Uniform Energy Factor (UEF)0.88At 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)118 gal-18 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency97%+2.0 pts vs. 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)55.7" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-12-12Certified 2025-12-12Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should A. O. Smith Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HDHE-50 4** production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?

Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American VG8250T100*V Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
GSW WATER HEATERS 8G-50100*PDV-H06* 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
RELIANCE WATER HEATERS 8-50-*TPDT 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
State GP-8-50-*TPDT 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
American VG6250T100*V 3** Gas-fired Storage Residential-duty Commercial 49 gal 100 gal 0.88 (at parity) —

Which Home Setups Are NOT a Fit for A. O. Smith HDHE-50 4**?

Comparing A. O. Smith HDHE-50 4** against American VG8250T100*V requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • A. O. Smith HDHE-50 4** logs 0.88 UEF (Pass: +0.30 / +51.7%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect A. O. Smith HDHE-50 4**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 118 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for A. O. Smith HDHE-50 4** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like American VG8250T100*V.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Frequently Asked Technical Questions: A. O. Smith HDHE-50 4**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith HDHE-50 4** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith HDHE-50 4** logs 0.88 UEF (Pass: +0.30 / +51.7%) within the 71-unit Gas-fired Storage Residential-duty Commercial group.

What physical clearance dimensions apply when installing A. O. Smith HDHE-50 4**?

With a 55.7 in. height and 18 in. diameter, A. O. Smith HDHE-50 4** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits A. O. Smith HDHE-50 4**?

A. O. Smith HDHE-50 4** utilizes Natural Gas, Propane combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for A. O. Smith HDHE-50 4**?

A. O. Smith HDHE-50 4** operates on Natural Gas, Propane (0.88 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing A. O. Smith HDHE-50 4**?

Homes with >10.5 GPG Very Hard well water without regular 6-month sediment draining will shorten the tank life of A. O. Smith HDHE-50 4** (Pass: +0.30 / +51.7%).

Is A. O. Smith HDHE-50 4** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies A. O. Smith HDHE-50 4** at 118 gal First Hour Rating (-18 gal vs. 136 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does A. O. Smith have active CPSC SaferProducts notices affecting HDHE-50 4**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches A. O. Smith HDHE-50 4** (0.88 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith HDHE-50 4**. Closest peer in Gas-fired Storage Residential-duty Commercial is American VG8250T100*V (0.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks