Skip to main content
ENERGY STAR water heater model · PD 4692192

Rheem PROPH40 T2 RH400-Z30 Water Heater Specifications (3.83 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem PROPH40 T2 RH400-Z30 achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating and ranks #230 of 706 in its 706-model cohort (PD 4692192), recording Pass: +1.53 / +66.5% under 2029 DOE rules. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Uniform Energy Factor
3.83 UEF
Cohort UEF Rank
#230 of 706 (top 37.8%)
First Hour Rating
60 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.53 / +66.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem PROPH40 T2 RH400-Z30 at 3.83 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Rheem PROPH40 T2 RH400-Z30: 3.83
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem PROPH40 T2 RH400-Z30 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem PROPH40 T2 RH400-Z30 logs 3.83 UEF and ranks #230 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Rheem PROPH40 T2 RH400-Z30 holds a +1.53 UEF (+66.5%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Rheem PROPH40 T2 RH400-Z30 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem PROPH40 T2 RH400-Z30: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rheem PROPH40 T2 RH400-Z30 (3.83 UEF)? Check Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) and Richmond 10CE40-HP5U30 (3.83 UEF, at parity).

How Complete Are the Certified Metrics for Rheem PROPH40 T2 RH400-Z30?

Standing at #230 of 706 (top 37.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Rheem PROPH40 T2 RH400-Z30 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 4692192
Model NumberPROPH40 T2 RH400-Z30Draw pattern: Medium-UsagePROPH40 T2 RH400-Z30
Uniform Energy Factor (UEF)3.83+0.13 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)60 gal-12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use859 kWh/yr-213 kWh/yr vs. 1,072 kWh/yr medianEst. $156/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency434%+5.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-1234YFLower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Is the Projected Utility Bill for PROPH40 T2 RH400-Z30 by State?

At 859 kWh/yr, Rheem PROPH40 T2 RH400-Z30 averages about $156/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (859 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$156.00/yrHawaii$405.00/yrCalifornia$256.00/yrTexas$137.00/yrWashington$126.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $156/yr $1,560 $4,934
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $405/yr $4,053 $12,819
California 29.75 ¢/kWh ($0.2975) $256/yr $2,556 $8,083
Texas 15.91 ¢/kWh ($0.1591) $137/yr $1,367 $4,323
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $126/yr $1,257 $3,975
Estimated electricity spend (859 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Rheem Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to PROPH40 T2 RH400-Z30?

Ordered by minimal capacity and UEF spread relative to Rheem PROPH40 T2 RH400-Z30, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Richmond 10CE40-HP5U30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Ruud CPROPH40 T2 CD375-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (-0.23) 902
Friedrich PROH40 T2 FD400-SO Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859

Which Home Setups Are NOT a Fit for Rheem PROPH40 T2 RH400-Z30?

Comparing Rheem PROPH40 T2 RH400-Z30 against Friedrich PROH40 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Rheem PROPH40 T2 RH400-Z30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem PROPH40 T2 RH400-Z30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem PROPH40 T2 RH400-Z30 Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

Practical Specs & Code Questions for Rheem PROPH40 T2 RH400-Z30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rheem PROPH40 T2 RH400-Z30 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem PROPH40 T2 RH400-Z30 logs 3.83 UEF (Pass: +1.53 / +66.5%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Rheem PROPH40 T2 RH400-Z30?

With a 62.3 in. height and 20.3 in. diameter, Rheem PROPH40 T2 RH400-Z30 fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Rheem PROPH40 T2 RH400-Z30?

Powered via 240V at 21A max, Rheem PROPH40 T2 RH400-Z30 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Rheem PROPH40 T2 RH400-Z30?

Annual electric spend for Rheem PROPH40 T2 RH400-Z30 (859 kWh/yr) averages $156/yr nationwide (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Rheem PROPH40 T2 RH400-Z30?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem PROPH40 T2 RH400-Z30.

Is Rheem PROPH40 T2 RH400-Z30 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Rheem PROPH40 T2 RH400-Z30 at 60 gal First Hour Rating (-12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Rheem have active CPSC SaferProducts notices affecting PROPH40 T2 RH400-Z30?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches Rheem PROPH40 T2 RH400-Z30 (3.83 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem PROPH40 T2 RH400-Z30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks