Skip to main content
ENERGY STAR water heater model · PD 4572778

Richmond 10CE40-HP5US30 Water Heater Specifications (3.83 UEF)

With PD 4572778 certification, Richmond 10CE40-HP5US30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, standing #230 of 706 across 706 peers with Pass: +1.53 / +66.5% for May 6, 2029. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Uniform Energy Factor
3.83 UEF
Cohort UEF Rank
#230 of 706 (top 37.8%)
First Hour Rating
60 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.53 / +66.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10CE40-HP5US30 at 3.83 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Richmond 10CE40-HP5US30: 3.83
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10CE40-HP5US30 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Richmond 10CE40-HP5US30 at 3.83 UEF (#230 of 706; +0.13 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Richmond 10CE40-HP5US30 stands +1.53 UEF (+66.5%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Richmond 10CE40-HP5US30 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10CE40-HP5US30: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) and Rheem CPROPH40 T2 RH400-30 (3.83 UEF, at parity) bracket Richmond 10CE40-HP5US30.

How Do Richmond 10CE40-HP5US30 Specs Compare to Hybrid/Electric Heat Pump Medians?

Richmond 10CE40-HP5US30 places #230 of 706 (top 37.8%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 4572778
Model Number10CE40-HP5US30Draw pattern: Medium-Usage10CE40-HP5US30
Uniform Energy Factor (UEF)3.83+0.13 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)60 gal-12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use859 kWh/yr-213 kWh/yr vs. 1,072 kWh/yr medianEst. $156/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency434%+5.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-24Certified 2026-03-24Markets: Canada

What Does 10CE40-HP5US30 Cost to Operate Across State Electricity Rates?

At 859 kWh/yr, Richmond 10CE40-HP5US30 runs roughly $156/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (859 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$156.00/yrHawaii$405.00/yrCalifornia$256.00/yrTexas$137.00/yrWashington$126.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $156/yr $1,560 $4,934
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $405/yr $4,053 $12,819
California 29.75 ¢/kWh ($0.2975) $256/yr $2,556 $8,083
Texas 15.91 ¢/kWh ($0.1591) $137/yr $1,367 $4,323
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $126/yr $1,257 $3,975
Estimated electricity spend (859 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Richmond Water Heaters?

Zero active CPSC recalls matched Richmond in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match 10CE40-HP5US30 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Richmond 10CE40-HP5US30 by storage capacity and 3.83 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Rheem CPROPH40 T2 RH400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Ruud CPROPH40 T2 CD375-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (-0.23) 902
Friedrich PROH40 T2 FD400-SO Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859

What Are the Limitations of Richmond 10CE40-HP5US30 and Who Should Not Install It?

Before ordering Richmond 10CE40-HP5US30 (Hybrid/Electric Heat Pump, 3.83 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Richmond 10CE40-HP5US30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10CE40-HP5US30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10CE40-HP5US30 Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

What Are the Key Questions About Richmond 10CE40-HP5US30?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Richmond 10CE40-HP5US30 pass the May 6, 2029 federal DOE efficiency rule?

Richmond 10CE40-HP5US30 carries a verified 3.83 UEF rating (Pass: +1.53 / +66.5%), ranking #230 of 706 (top 37.8%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Richmond 10CE40-HP5US30 need?

Richmond 10CE40-HP5US30 stands 62.3 in. high with a 20.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Richmond 10CE40-HP5US30 require?

Richmond 10CE40-HP5US30 uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Richmond 10CE40-HP5US30 cost per year to run?

Rated at 859 kWh/yr, Richmond 10CE40-HP5US30 costs about $156/yr ($1,560 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii).

Who should NOT install Richmond 10CE40-HP5US30, and what are its limits?

Richmond 10CE40-HP5US30 (3.83 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Richmond 10CE40-HP5US30 serve at peak demand?

Richmond 10CE40-HP5US30 achieves a 60 gal First Hour Rating (-12 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Richmond 10CE40-HP5US30?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 10CE40-HP5US30 because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Richmond 10CE40-HP5US30, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)